We conclude that > or = 70% carotid stenosis can be reliably determined by duplex Doppler ultrasound. Individual vascular laboratories must validate their own results.
It is concluded that 60% or greater carotid artery stenosis can be reliably determined by duplex criteria. The use of receiver-operator characteristic curves allows the individualization of duplex criteria appropriate to specific clinical situations of patient screening for lesions (high sensitivity and NPV) or use as a sole preoperative imaging modality (high PPV). Individual vascular laboratories must validate their own results.
Recently the North American Symptomatic Carotid Endarterectomy Trial investigators reported a benefit of carotid endarterectomy compared with medical therapy for symptomatic patients with 50% or greater carotid stenosis. This has necessitated the development of screening parameters for diagnosis of 50% or greater carotid stenosis on the basis of the reference standards used in the study by the North American Symptomatic Carotid Endarterectomy Trial. The duplex scans and arteriograms of 110 patients (210 carotid arteries) were reviewed by blinded readers. Duplex measurements of peak systolic velocity and end diastolic velocity were recorded, and the ratio of these velocities in the internal and common carotid arteries was calculated. The criteria determined for detection of 50% or greater stenosis were as follows: peak systolic velocity of the internal carotid artery greater than 170 cm/s (sensitivity, 92%; specificity, 90%; positive predictive value, 92%; negative predictive value, 90%; and accuracy, 91 %); end diastolic velocity of the internal carotid artery greater than 60 cm/s (sensitivity, 92%; specificity, 86%; positive predictive value, 95%; negative predictive value, 79%; and accuracy, 91 %); ratio of peak systolic velocity of the internal carotid artery to peak systolic velocity of the common carotid artery greater than 2 (sensitivity, 93%; specificity, 75%; positive predictive value, 83%; negative predictive value, 89%; and accuracy, 85%); and ratio of end diastolic velocity of the internal carotid artery to end diastolic velocity of the common carotid artery greater than 2.4 (sensitivity, 96%; specificity, 79%; positive predictive value, 88%; negative predictive value, 92%; and accuracy, 89%). It is concluded that 50% or greater carotid artery stenosis can be reliably determined by duplex criteria. The use of receiver operating characteristic curves allows the individualization of duplex criteria to the clinical situation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.