Community-based studies suggest that cannabis products that are high in Δ⁹-tetrahydrocannabinol (THC) but low in cannabidiol (CBD) are particularly hazardous for mental health. Laboratory-based studies are ideal for clarifying this issue because THC and CBD can be administered in pure form, under controlled conditions. In a between-subjects design, we tested the hypothesis that pre-treatment with CBD inhibited THC-elicited psychosis and cognitive impairment. Healthy participants were randomised to receive oral CBD 600 mg (n=22) or placebo (n=26), 210 min ahead of intravenous (IV) THC (1.5 mg). Post-THC, there were lower PANSS positive scores in the CBD group, but this did not reach statistical significance. However, clinically significant positive psychotic symptoms (defined a priori as increases ≥ 3 points) were less likely in the CBD group compared with the placebo group, odds ratio (OR)=0.22 (χ²=4.74, p<0.05). In agreement, post-THC paranoia, as rated with the State Social Paranoia Scale (SSPS), was less in the CBD group compared with the placebo group (t=2.28, p<0.05). Episodic memory, indexed by scores on the Hopkins Verbal Learning Task-revised (HVLT-R), was poorer, relative to baseline, in the placebo pre-treated group (-10.6 ± 18.9%) compared with the CBD group (-0.4% ± 9.7 %) (t=2.39, p<0.05). These findings support the idea that high-THC/low-CBD cannabis products are associated with increased risks for mental health.
The main ingredient in cannabis, Δ(9)-tetrahydrocannabinol (THC), can elicit acute psychotic reactions in healthy individuals and precipitate relapse in schizophrenic patients. However, the neural mechanism of this is unknown. We tested the hypothesis that THC psychopathology is related to changes in electroencephalography (EEG) power or inter-regional coherence. In a within-subjects design, participants (n=16) were given intravenous THC (1.25 mg) or placebo under double-blind conditions, during EEG recordings. Using fast-Fourier transform, EEG data were analyzed for power and coherence in the delta (1-3.5 Hz), theta (3.5-7 Hz), alpha (8-13 Hz), beta (14-25 Hz), low-gamma (30-40 Hz), and high-gamma (60-70 Hz) bands during engagement in the n-back test of working memory (WM). Compared with placebo, THC evoked positive and negative psychotic symptoms, as measured by the positive and negative syndrome scale (p<0.001) and slowed WM performance (p<0.05). Under THC, theta power was specifically reduced, (p<0.001) regardless of WM load; however, the reduction showed no relationship with psychotic symptoms or WM impairment. Coherence between bi-frontal electrodes in the theta band was also reduced by THC (p<0.05) and these reductions correlated with the change-in positive psychotic symptoms (rho=0.79, p<0.001). Bi-frontal specificity was suggested by the absence of a relationship between psychotic symptoms and fronto-parietal coherence. The results reveal that the pro-psychotic effects of THC might be related to impaired network dynamics with impaired communication between the right and left frontal lobes.
Abnormal gamma oscillations, measured by electroencephalography (EEG), have been associated with chronic psychotic disorders, but their prevalence in the early phase of psychosis is less clear. We sought to address this by systematically reviewing the relevant literature. We searched for EEG studies of gamma band oscillations in subjects at high risk for psychosis and in patients with first episode psychosis. The following measures of gamma oscillations were extracted: resting power, evoked power, induced power, connectivity and peak frequency. Forty-five studies with a total of 3099 participants were included. There were potential sources of bias in the study designs and potential artefacts. Although there were few consistent findings, several studies reported decreased evoked or induced power in both high risk subjects and first episode patients. Studies using larger samples with serial EEG measurements, and designs that minimise artefacts that occur at the gamma frequency may advance work in this area.
BackgroundFinding reliable endophenotypes for psychosis could lead to an improved understanding of aetiology, and provide useful alternative phenotypes for genetic association studies. Resting quantitative electroencephalography (QEEG) activity has been shown to be heritable and reliable over time. However, QEEG research in patients with psychosis has shown inconsistent and even contradictory findings, and studies of at-risk populations are scarce. Hence, this study aimed to investigate whether resting QEEG activity represents a candidate endophenotype for psychosis.MethodQEEG activity at rest was compared in four frequency bands (delta, theta, alpha, and beta), between chronic patients with psychosis (N = 48), first episode patients (N = 46), at-risk populations (“at risk mental state”, N = 33; healthy relatives of patients, N = 45), and healthy controls (N = 107).ResultsResults showed that chronic patients had significantly increased resting QEEG amplitudes in delta and theta frequencies compared to healthy controls. However, first episode patients and at-risk populations did not differ from controls in these frequency bands. There were no group differences in alpha or beta frequency bands.ConclusionSince no abnormalities were found in first episode patients, ARMS, or healthy relatives, resting QEEG activity in the frequency bands examined is unlikely to be related to genetic predisposition to psychosis. Rather than endophenotypes, the low frequency abnormalities observed in chronic patients are probably related to illness progression and/or to the long-term effects of treatments.
Neural oscillations in the gamma band are of increasing interest, but separating them from myogenic electrical activity has proved difficult. A novel algorithm has been developed to reduce the effect of tonic scalp and neck muscle activity on the gamma band of the EEG. This uses mathematical modelling to fit individual muscle spikes and then subtracts them from the data. The method was applied to the detection of motor associated gamma in two separate groups of eight subjects using different sampling rates. A reproducible increase in high gamma (65–85 Hz) magnitude occurred immediately after the motor action in the left central area (p = 0.02 and p = 0.0002 for the two cohorts with individually optimized algorithm parameters, compared to p = 0.03 and p = 0.16 before correction). Whilst the magnitude of this event-related gamma synchronisation was not reduced by the application of the EMG reduction algorithm, the baseline left central gamma magnitude was significantly reduced by an average of 23 % with a faster sampling rate (p < 0.05). In comparison, at left and right temporo-parietal locations the gamma amplitude was reduced by 60 and 54 % respectively (p < 0.05). The reduction of EMG contamination by fitting and subtraction of individual spikes shows promise as a method of improving the signal to noise ratio of high frequency neural oscillations in scalp EEG.
In this paper, a novel source extraction method is proposed for removing ballistocardiogram (BCG) artifact from EEG. BCG appears in EEG signals recorded simultaneously with functional magnetic resonance imaging. The proposed method is a semiblind source extraction algorithm based on linear prediction technique. We define a cost function according to a joint short- and long-term prediction strategy to extract the BCG sources. We call this method SLTP-BSE standing for short- and long-term prediction blind source extraction. The objective of this work is to 1) model the temporal structure of the sources using short-term prediction and 2) impose the prior information about the BCG sources using long-term prediction. These two procedures are simultaneously implemented to optimize the system. The performance of the proposed method is evaluated using both synthetic and real EEG data. The obtained results show that the proposed technique is able to remove the BCG artifact while preserving the task-related parts of the signal. The results of SLTP-BSE are compared with those of well-known BCG removal techniques confirming the superiority of the proposed method.
Gamma oscillations (>30 Hz) in the brain are involved in attention, perception and memory. They are altered in various pathological states, as well as by neuropharmaceuticals, so that they are of interest in drug and clinical investigations. However, when the human electroencephalogram is recorded on the scalp, this neural high-frequency signal is buried under a range of other electrical signals such that, without careful handling, recordings of the high-frequency electroencephalogram cannot be considered reliable. The artefacts of concern originate from: power line noise, saccade-associated contraction of the extra-ocular muscles, activity of muscles in the scalp, face and neck, screen refresh artefacts and activity of the muscles associated with blinking. Recent progress in dealing with these artefacts is described, including either noise cancellation or phased noise template subtraction for power line noise, regression or independent component analysis for correcting extra-ocular muscle activity and mathematical modelling for reducing scalp, face and neck muscle activity. If the artefacts are properly addressed, the neural gamma signal can be uncovered.
RationaleAn acute challenge with delta-9-tetrahydrocannabinol (THC) can induce psychotic symptoms including delusions. High electroencephalography (EEG) frequencies, above 20 Hz, have previously been implicated in psychosis and schizophrenia.ObjectivesThe objective of this study is to determine the effect of intravenous THC compared to placebo on high-frequency EEG.MethodsA double-blind cross-over study design was used. In the resting state, the high-beta to low-gamma magnitude (21–45 Hz) was investigated (n = 13 pairs + 4 THC only). Also, the event-related synchronisation (ERS) of motor-associated high gamma was studied using a self-paced button press task (n = 15).ResultsIn the resting state, there was a significant condition × frequency interaction (p = 0.00017), consisting of a shift towards higher frequencies under THC conditions (reduced high beta [21–27 Hz] and increased low gamma [27–45 Hz]). There was also a condition × frequency × location interaction (p = 0.006), such that the reduction in 21–27-Hz magnitude tended to be more prominent in anterior regions, whilst posterior areas tended to show greater 27–45-Hz increases. This effect was correlated with positive symptoms, as assessed on the Positive and Negative Syndrome Scale (PANSS) (r = 0.429, p = 0.042). In the motor task, there was a main effect of THC to increase 65–130-Hz ERS (p = 0.035) over contra-lateral sensorimotor areas, which was driven by increased magnitude in the higher, 85–130-Hz band (p = 0.02) and not the 65–85-Hz band.ConclusionsThe THC-induced shift to faster gamma oscillations may represent an over-activation of the cortex, possibly related to saliency misattribution in the delusional state.Electronic supplementary materialThe online version of this article (doi:10.1007/s00213-014-3684-1) contains supplementary material, which is available to authorized users.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.