a b s t r a c tThe double cantilever beam (DCB) method for adhesive toughness measurement was improved by incorporating a sufficiently sharp crack made by a wedge-tapping method. A known route to producing cracks via loading-unloading cycles was proved unreliable because the cycles produced plastic deformation in the adhesive where new cracks propagated. Abnormally high toughness values with large standard deviations were obtained with cracks made by embedding a non-sticky insert. Only instantly propagated cracks made by tapping were sufficiently sharp to produce reproducible, accurate toughness measurements. However, toughened resin was insensitive to crack sharpness. A crack length to adherend length ratio of 0.2-0.5 is recommended.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.