The majority of reported complications after ICL implantation are cataract formation. The improvements in lens geometry and more accurate nomograms applied to the selection of the lens to be implanted, in addition to the surgeon's learning curve, might be factors in the decreased occurrence of postoperative complications reported currently.
CRT inverts the pattern of peripheral refraction in spherical equivalent refraction, creating a treatment area of myopic reduction within the central 25 degrees of visual field, and a myopic shift beyond the 25 degrees. In peripheral refraction for 30 degrees and 35 degrees, the amount of myopia induced in terms of spherical equivalent has an almost 1:1 relationship with the amount of baseline spherical equivalent refraction to be corrected.
The aim of this study was to evaluate the accuracy of measurement of intraocular pressure (IOP) using a new induction/impact rebound tonometer (ICare) in comparison with the Goldmann applanation tonometer (AT). The left eyes of 46 university students were assessed with the two tonometers, with induction tonometry being performed first. The ICare was handled by an optometrist and the Goldmann tonometer by an ophthalmologist. In this study, statistically significant differences were found when comparing the ICare rebound tonometer with applanation tonometry (AT) (p < 0.05). The mean difference between the two tonometers was 1.34 +/- 2.03 mmHg (mean +/- S.D.) and the 95% limits of agreement were +/-3.98 mmHg. A frequency distribution of the differences demonstrated that in more than 80% of cases the IOP readings differed by <3 mmHg between the ICare and the AT. In the present population the ICare overestimates the IOP value by 1.34 mmHg on average when compared with Goldmann tonometer. Nevertheless, the ICare tonometer may be helpful as a screening tool when Goldmann applanation tonometry is not applicable or not recommended, as it is able to estimate IOP within a range of +/-3.00 mmHg in more than 80% of the population.
The aim of the present study was to assess the level of accuracy for measurements of intra-ocular pressure (IOP) obtained with a new non-contact tonometer (NCT) the Reichert AT550. Measurements were compared against those obtained with the Reichert Xpert Plus, Goldmann applanation tonometer and Perkins tonometer. Thirty-five university students were assessed with the four tonometers in a randomised order, with non-contact tonometry performed first. Each of the four measurement devices had its own trained clinical observer. Plots of differences of IOP as a function of the mean for each pair of instruments were obtained. No statistically significant differences were found when comparing the AT550 NCT with contact applanation tonometry (AT) (p> 0.05), displaying the closest level of agreement (as represented by the lowest mean difference and the narrowest confidence interval) with the Goldmann tonometer (limits of agreement, 0.12+/-2.17). In conclusion, readings of IOP with the AT550 NCT are clinically comparable with those obtained with Goldmann tonometry in a population with IOP within the normal range.
Decrease in subjective vault after ICL implantation became statistically significant after the third month postoperatively. Several patients and lens-related factors have been identified as potential predictors of ASC or acute increase in IOP. A tight follow-up during the critical post-operative period should be considered in those particular cases.
Multifocal contact lens correction provided satisfactory levels of VA comparable with MV without compromising stereoacuity in this crossover study. The near vision significantly improved in the dominant eye, and the distance vision improved in the nondominant eye from 1 to 15 days with the MF lens, suggesting that patients adapted to the multifocality overtime, whereas this was not true for MV.
IOP values obtained with the rebound tonometer are higher in thicker corneas and are positively correlated with biomechanical corneal parameters, namely corneal resistance factor. Although corneal thickness plays a significant role in rebound tonometry, elastic and viscous properties of the cornea seem to play a significant role in the interaction of the tonometer probe with the ocular surface. However, the mechanism behind this process is presently unknown.
Stable and progressing myopes of matched age, axial length, and central refraction showed significantly different characteristics in their peripheral retinal shape and astigmatic components of tangential and sagittal power errors. The present findings may help explain the mechanisms that regulate ocular growth in humans.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.