Even though the measures to minimize the stack effect in high-rise buildings were taken that include a revolving door on the lobby floor, additional barriers to the passage of air in the lower part of the building, and air-tightness reinforcement for elevator doors, the stack effect is still present during cold season in Korea. However, it is difficult to fully apply the measures for stack effect under occupied condition in high-rise buildings. In this study, as an advanced method to lower the stack effect in high-rise buildings under occupied condition, mechanical ventilation in elevator shaft space, which cools the shaft space with outdoor air and reduces the temperature or pressure differences between indoor air in shaft and outdoor air, was proposed. In this paper, the application details and performance analyses of the installed shaft cooling system in a completed building in Korea were described. Also, as a measure to improve the performance of the applied system, concentrated cooling in the lower part of the elevator shaft where there is a main air flow passage was proposed. As a result, cooling effect of mechanical ventilation system in elevator shaft was improved and the extent of stack effect in winter was decreased effectively.
Drafts in high-rise buildings caused by the stack effect can cause noise and reduce the performances of ventilation, cooling and heating systems as well as the building’s energy efficiency. Revolving doors are generally used as a method to reduce drafts; however, the effect would only be limited to the main entrance on the lobby floor.
Revolving doors have two main advantages; that their opening areas are seldom changed by people passing through the doors, and the doors do not have the pressure-related functional problems. Considering these advantages, this study examined a quantitative draft reduction method using revolving doors in high-rise buildings. This method would contribute to the design process to install revolving doors to buildings and consists of 10 steps with two key steps of selecting the installation locations of revolving doors and to calculate the air leakage area of revolving doors. Verification through simulations showed that, based on this process, the use of revolving doors could reduce the drafts in buildings by a quantified target value. Furthermore, the possibility of problems due to the stack effect in the other walls of buildings would decrease due to the pressure sharing of the additional walls fitted to revolving doors.
Energy efficiency and indoor air quality have become main issue to develop healthy and sustainable building in these days. As an effort to reduce the energy consumption in multiresidential building, many attempts as like passive design strategies and renewable energy as well as active control method are tried. However, underground parking lot in multi-residential building seldom adopt the sustainable strategies and only mechanical system is installed as usual. Moreover, the mechanical system installed in underground parking lot is rarely operated due to the electric demand for operation after completion.In this study, as an energy efficient measure, natural ventilation system using stack effect as a driving force for underground parking lot will be proposed and the performance of the suggested system will be analyzed by simulation method.
Ventilation is one of the most important measures to dilute indoor air pollutants. In order to maintain a clean indoor air environment, not only the total ventilation rate of the building but also the distribution of outdoor air to each area must be taken into consideration. A performance evaluation of various ventilation systems, which have different air supply and exhaust equipment, has been made. This investigation was undertaken over a heating period, in a full-scale test house. The ventilation rate and distribution to each room of the test house were measured by the constant concentration method. The influence of indoor-outdoor temperature difference on ventilation rate was also analysed. The measurement results revealed the performance of these ventilation systems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.