Background:Digital slides obtained from whole slide imaging (WSI) platforms are typically viewed in two dimensions using desktop personal computer monitors or more recently on mobile devices. To the best of our knowledge, we are not aware of any studies viewing digital pathology slides in a virtual reality (VR) environment. VR technology enables users to be artificially immersed in and interact with a computer-simulated world. Oculus Rift is among the world's first consumer-targeted VR headsets, intended primarily for enhanced gaming. Our aim was to explore the use of the Oculus Rift for examining digital pathology slides in a VR environment.Methods:An Oculus Rift Development Kit 2 (DK2) was connected to a 64-bit computer running Virtual Desktop software. Glass slides from twenty randomly selected lymph node cases (ten with benign and ten malignant diagnoses) were digitized using a WSI scanner. Three pathologists reviewed these digital slides on a 27-inch 5K display and with the Oculus Rift after a 2-week washout period. Recorded endpoints included concordance of final diagnoses and time required to examine slides. The pathologists also rated their ease of navigation, image quality, and diagnostic confidence for both modalities.Results:There was 90% diagnostic concordance when reviewing WSI using a 5K display and Oculus Rift. The time required to examine digital pathology slides on the 5K display averaged 39 s (range 10–120 s), compared to 62 s with the Oculus Rift (range 15–270 s). All pathologists confirmed that digital pathology slides were easily viewable in a VR environment. The ratings for image quality and diagnostic confidence were higher when using the 5K display.Conclusion:Using the Oculus Rift DK2 to view and navigate pathology whole slide images in a virtual environment is feasible for diagnostic purposes. However, image resolution using the Oculus Rift device was limited. Interactive VR technologies such as the Oculus Rift are novel tools that may be of use in digital pathology.
Introduction:Whole slide imaging (WSI) permits intraoperative consultations (frozen sections) to be performed remotely. However, WSI files are large and can be problematic if there are tissue artifacts (e.g., tissue folds) or when slides are scanned without multiplanes (Z-stacks) to permit focusing. The Panoptiq dynamic imaging system allows users to create their own digital files that combine low power panoramic digital images with regions of interest that can be imaged using high power Z-stacks. The aim of this study was to determine the utility of the Panoptiq dynamic imaging system for frozen section telepathology.Materials and Methods:Twenty archival randomly selected genitourinary surgical pathology frozen sectional cases were evaluated using conventional light microscopy (glass slides), panoramic images, and whole slide images. To create panoramic images glass slides were digitized using a Prosilica GT camera (model GT1920C, Allied Vision Technologies) attached to an Olympus B × 45 microscope and Dell Precision Tower 810 computer (Dell). Panoptiq 3 version 3.1.2 software was used for image acquisition and Panoptiq View version 3.1.2 to view images (ViewsIQ, Richmond, BC, Canada). Image acquisition using Panoptiq software involved a pathology resident, who manually created digital maps (×4 objective) and then selected representative regions of interest to generate Z-stacks at higher magnification (×40 objective). Whole slide images were generated using an Aperio XT Scanscope (Leica) and viewed using ImageScope Software (Aperio ePathology, Leica). Three pathologists were asked to render diagnoses and rate image quality (1–10) and their diagnostic confidence (1–10) for each modality.Results:The diagnostic concordance with glass slides was 98.3% for panoramic images and 100% for WSI. Panoptiq images were comparable to the glass slide viewing experience in terms of image quality and diagnostic confidence. Complaints regarding WSI included poor focus near tissue folds and air bubbles. Panoptiq permitted fine focusing of tissue folds and air bubbles. Issues with panoramic images included difficulty interpreting low-resolution ×4 image maps and the presence of tiling artifacts. In some cases, Z-stacked areas of Panoptiq images were limited or not representative of diagnostic regions. The image file size of Panoptiq was more than 14 times smaller than that of WSI files.Conclusions:The Panoptiq imaging system is a novel tool that can be used for frozen section telepathology. Panoramic digital images were easy to generate and navigate, of relatively small file size, and offered a mechanism to overcome focusing problems commonly encountered with WSI of frozen sections. However, the acquisition of representative Panoptiq images was operator dependent with the individual creating files that may impact the final diagnosis.
Introduction:Telemicrobiology is a growing component of clinical microbiology informatics. However, few studies have been performed to assess the diagnostic utility of telemicroscopy systems in evaluating infectious agents.Objective:Evaluate multiple contemporary digital pathology platforms for use in diagnostic telemicrobiology.Materials and Methods:A mix of thirty cases that included viral, bacterial, fungal, and parasitological findings were evaluated by four experts using ×40 whole slide imaging (WSI) scans, ×83 oil-immersion WSI scans, ×100 oil-immersion WSI scans, digital photomicrographs, and glass slides.Results:The ×83 WSI, ×100 WSI, and photomicrograph interpretations were not significantly different in quality and accuracy when compared to glass slide interpretations. The ×40 WSI interpretations were of lower quality and were more likely to be incorrect when compared to glass slide interpretations.Conclusions:In this study, high magnification, oil-immersion digital pathology platforms are better suited to support telemicrobiology applications and yield interpretations on par with glass slide evaluations.
Diagnostic hematopathology requires a multiparametric approach and integration of morphologic findings with the clinical, immunophenotypic, and other features. As hematopathology moves into an increasingly digital era, internetdeployed teaching sets consisting of whole slide images (WSI) and comprehensive ancillary information can help prepare hematopathology trainees for the future. Approximately 200 hematopathology conference cases over a 1-year period were de-identified, and case information (including clinical, microscopic and immunophenotypic features, flow cytometric histograms, and cytogenetic and molecular results) were entered into a database. Approximately 1,800 WSI were prepared by scanning using ×40 magnification, and WSI and supplemental data were stored on separate servers and referenced in the database via hyperlinks. From January 2009 to November 2011, the website has been accessed over 6,000 times. The user can view the list of cases and brief clinical history, with or without the diagnosis displayed. Once a case is chosen, the complete clinical history, WSI, case data, and other hyperlinks are displayed, and the user can also scroll down to see the diagnosis shown at the end of the case. Preand post-test evaluations are available for self-assessment. The hematopathology virtual set is emerging as an important tool in hematopathology education. The internet-deployed database is unique in the wide range of ancillary studies readily accessible, which reinforces the multiparametric approach in hematopathology.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.