The authors have shown the feasibility of reconstructing volumetric images and localizing tumor positions in 3D in near real-time from a single x-ray image.
Accurate volumetric assessment in non-small cell lung cancer (NSCLC) is critical for adequately informing treatments. In this study we assessed the clinical relevance of a semiautomatic computed tomography (CT)-based segmentation method using the competitive region-growing based algorithm, implemented in the free and public available 3D-Slicer software platform. We compared the 3D-Slicer segmented volumes by three independent observers, who segmented the primary tumour of 20 NSCLC patients twice, to manual slice-by-slice delineations of five physicians. Furthermore, we compared all tumour contours to the macroscopic diameter of the tumour in pathology, considered as the “gold standard”. The 3D-Slicer segmented volumes demonstrated high agreement (overlap fractions > 0.90), lower volume variability (p = 0.0003) and smaller uncertainty areas (p = 0.0002), compared to manual slice-by-slice delineations. Furthermore, 3D-Slicer segmentations showed a strong correlation to pathology (r = 0.89, 95%CI, 0.81–0.94). Our results show that semiautomatic 3D-Slicer segmentations can be used for accurate contouring and are more stable than manual delineations. Therefore, 3D-Slicer can be employed as a starting point for treatment decisions or for high-throughput data mining research, such as Radiomics, where manual delineating often represent a time-consuming bottleneck.
9 10Purpose: To evaluate an algorithm for real-time 3D tumor localization from a single x-11 ray projection image for lung cancer radiotherapy. 13Methods: Recently we have developed an algorithm for reconstructing volumetric
Respiration-induced organ motion is one of the major uncertainties in lung cancer radiotherapy and is crucial to be able to accurately model the lung motion. Most work so far has focused on the study of the motion of a single point (usually the tumor center of mass), and much less work has been done to model the motion of the entire lung. Inspired by the work of Zhang et al (2007 Med. Phys. 34 4772–81), we believe that the spatiotemporal relationship of the entire lung motion can be accurately modeled based on principle component analysis (PCA) and then a sparse subset of the entire lung, such as an implanted marker, can be used to drive the motion of the entire lung (including the tumor). The goal of this work is twofold. First, we aim to understand the underlying reason why PCA is effective for modeling lung motion and find the optimal number of PCA coefficients for accurate lung motion modeling. We attempt to address the above important problems both in a theoretical framework and in the context of real clinical data. Second, we propose a new method to derive the entire lung motion using a single internal marker based on the PCA model. The main results of this work are as follows. We derived an important property which reveals the implicit regularization imposed by the PCA model. We then studied the model using two mathematical respiratory phantoms and 11 clinical 4DCT scans for eight lung cancer patients. For the mathematical phantoms with cosine and an even power (2n) of cosine motion, we proved that 2 and 2n PCA coefficients and eigenvectors will completely represent the lung motion, respectively. Moreover, for the cosine phantom, we derived the equivalence conditions for the PCA motion model and the physiological 5D lung motion model (Low et al 2005 Int. J. Radiat. Oncol. Biol. Phys. 63 921–9). For the clinical 4DCT data, we demonstrated the modeling power and generalization performance of the PCA model. The average 3D modeling error using PCA was within 1 mm (0.7 ± 0.1 mm). When a single artificial internal marker was used to derive the lung motion, the average 3D error was found to be within 2 mm (1.8 ± 0.3 mm) through comprehensive statistical analysis. The optimal number of PCA coefficients needs to be determined on a patient-by-patient basis and two PCA coefficients seem to be sufficient for accurate modeling of the lung motion for most patients. In conclusion, we have presented thorough theoretical analysis and clinical validation of the PCA lung motion model. The feasibility of deriving the entire lung motion using a single marker has also been demonstrated on clinical data using a simulation approach.
Modafinil demonstrated promise in reducing methamphetamine use in selected methamphetamine-dependent patients. The study findings support definitive trials of modafinil in larger multi-site trials.
Algorithms for direct tumor tracking in rotational cone-beam projections and for reconstruction of phase-binned 3D tumor trajectories were developed. The feasibility of the algorithm was demonstrated on a digital phantom, a physical phantom and two patients. Tracking results were obtained by comparing reference templates generated from 4DCT to rotational cone-beam projections. The 95th percentile absolute errors (e(95)) in phantom tracking results did not exceed 1.7 mm in either imager dimension, while e(95) in the patients was 3.3 mm or less. Accurate phase-binned trajectories were reconstructed in each case, with 3D maximum errors of no more than 1.0 mm in the phantoms and 2.0 mm in the patients. This work shows the feasibility of a direct tumor tracking technique for rotational images, and demonstrates that an accurate 3D tumor trajectory can be reconstructed from relatively less accurate tracking results. The ability to reconstruct the tumor's average trajectory from a 3D cone-beam CT scan on the day of treatment could allow for better patient setup and quality assurance, while direct tumor tracking in rotational projections could be clinically useful for rotational therapy such as volumetric modulated arc therapy (VMAT).
Background and AimsQuestions over the clinical significance of cannabis withdrawal have hindered its inclusion as a discrete cannabis induced psychiatric condition in the Diagnostic and Statistical Manual of Mental Disorders (DSM IV). This study aims to quantify functional impairment to normal daily activities from cannabis withdrawal, and looks at the factors predicting functional impairment. In addition the study tests the influence of functional impairment from cannabis withdrawal on cannabis use during and after an abstinence attempt.Methods and ResultsA volunteer sample of 49 non-treatment seeking cannabis users who met DSM-IV criteria for dependence provided daily withdrawal-related functional impairment scores during a one-week baseline phase and two weeks of monitored abstinence from cannabis with a one month follow up. Functional impairment from withdrawal symptoms was strongly associated with symptom severity (p = 0.0001). Participants with more severe cannabis dependence before the abstinence attempt reported greater functional impairment from cannabis withdrawal (p = 0.03). Relapse to cannabis use during the abstinence period was associated with greater functional impairment from a subset of withdrawal symptoms in high dependence users. Higher levels of functional impairment during the abstinence attempt predicted higher levels of cannabis use at one month follow up (p = 0.001).ConclusionsCannabis withdrawal is clinically significant because it is associated with functional impairment to normal daily activities, as well as relapse to cannabis use. Sample size in the relapse group was small and the use of a non-treatment seeking population requires findings to be replicated in clinical samples. Tailoring treatments to target withdrawal symptoms contributing to functional impairment during a quit attempt may improve treatment outcomes.
Purpose The improved soft tissue contrast of magnetic resonance imaging (MRI) compared to computed tomography (CT) makes it a useful imaging modality for radiotherapy treatment planning. Even when MR images are acquired for treatment planning, the standard clinical practice currently also requires a CT for dose calculation and x‐ray–based patient positioning. This increases workloads, introduces uncertainty due to the required inter‐modality image registrations, and involves unnecessary irradiation. While it would be beneficial to use exclusively MR images, a method needs to be employed to estimate a synthetic CT (sCT) for generating electron density maps and patient positioning reference images. We investigated 2D and 3D convolutional neural networks (CNNs) to generate a male pelvic sCT using a T1‐weighted MR image and compare their performance. Methods A retrospective study was performed using CTs and T1‐weighted MR images of 20 prostate cancer patients. CTs were deformably registered to MR images to create CT‐MR pairs for training networks. The proposed 2D CNN, which contained 27 convolutional layers, was modified from the state‐of‐the‐art 2D CNN to save computational memory and prepare for building the 3D CNN. The proposed 2D and 3D models were trained from scratch to map intensities of T1‐weighted MR images to CT Hounsfield Unit (HU) values. Each sCT was generated in a fivefold cross‐validation framework and compared with the corresponding deformed CT (dCT) using voxel‐wise mean absolute error (MAE). The sCT geometric accuracy was evaluated by comparing bone regions, defined by thresholding at 150 HU in the dCTs and the sCTs, using dice similarity coefficient (DSC), recall, and precision. To evaluate sCT patient positioning accuracy, bone regions in dCTs and sCTs were rigidly registered to the corresponding cone‐beam CTs. The resulting paired Euler transformation vectors were compared by calculating translation vector distances and absolute differences of Euler angles. Statistical tests were performed to evaluate the differences among the proposed models and Han’s model. Results Generating a pelvic sCT required approximately 5.5 s using the proposed models. The average MAEs within the body contour were 40.5 ± 5.4 HU (mean ± SD) and 37.6 ± 5.1 HU for the 2D and 3D CNNs, respectively. The average DSC, recall, and precision for the bone region (thresholding the CT at 150 HU) were 0.81 ± 0.04, 0.85 ± 0.04, and 0.77 ± 0.09 for the 2D CNN, and 0.82 ± 0.04, 0.84 ± 0.04, and 0.80 ± 0.08 for the 3D CNN, respectively. For both models, mean translation vector distances are less than 0.6 mm with mean absolute differences of Euler angles less than 0.5°. Conclusions The 2D and 3D CNNs generated accurate pelvic sCTs for the 20 patients using T1‐weighted MR images. Statistical tests indicated that the proposed 3D model was able to generate sCTs with smaller MAE and higher bone region precision compared to 2D models. Results of patient alignment tests suggested that sCTs generated by the proposed CNNs can provide accurate pa...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.