The current UK code of practice for high-energy photon therapy dosimetry (Lillicrap et al 1990 Phys. Med. Biol. 35 1355-60) gives instructions for measuring absorbed dose to water under reference conditions for megavoltage photons. The reference conditions and the index used to specify beam quality require that a machine be able to set a 10 cm × 10 cm field at the point of measurement. TomoTherapy machines have a maximum collimator setting of 5 cm × 40 cm at a source to axis distance of 85 cm, making it impossible for users of these machines to follow the code. This addendum addresses the specification of reference irradiation geometries, the choice of ionization chambers and the determination of dosimetry corrections, the derivation of absorbed dose to water calibration factors and choice of appropriate chamber correction factors, for carrying out reference dosimetry measurements on TomoTherapy machines. The preferred secondary standard chamber remains the NE2611 chamber, which with its associated secondary standard electrometer, is calibrated at the NPL through the standard calibration service for MV photon beams produced on linear accelerators with conventional flattening filters. Procedures are given for the derivation of a beam quality index specific to the TomoTherapy beam that can be used in the determination of a calibration coefficient for the secondary standard chamber from its calibration certificate provided by the NPL. The recommended method of transfer from secondary standard to field instrument is in a static beam, at a depth of 5 cm, by sequential substitution or by simultaneous side by side irradiation in either a water phantom or a water-equivalent solid phantom. Guidance is given on the use of a field instrument in reference fields.
The 1990 code of practice (COP), produced by the IPSM (now the Institute of Physics and Engineering in Medicine, IPEM) and the UK National Physical Laboratory (NPL), gave instructions for determining absorbed dose to water for megavoltage photon (MV) radiotherapy beams (Lillicrap et al. Phys. Med. Biol. 1990 35 1355. The simplicity and clarity of the 1990 COP led to widespread uptake and high levels of consistency in external dosimetry audits. An addendum was published in 2014 to include the non-conventional conditions in Tomotherapy units. However, the 1990 COP lacked detailed recommendations for calibration conditions, and the corresponding nomenclature, to account for modern treatment units with different reference fields, including small fields as described in IAEA TRS483 (International Atomic Energy Agency, Vienna 2017). This updated COP recommends the irradiation geometries, the choice of ionisation chambers, appropriate correction factors and the derivation of absorbed dose to water calibration coefficients, for carrying out reference dosimetry measurements on MV external beam radiotherapy machines. It also includes worked examples of application to different conditions.The strengths of the 1990 COP are retained: recommending the NPL2611 chamber type as secondary standard; the use of tissue phantom ratio (TPR) as the beam quality specifier; and NPL-provided direct calibration coefficients for the user's chamber in a range of beam qualities similar to those in clinical use. In addition, the formalism is now extended to units that cannot achieve the standard reference field size of 10 cm × 10 cm, and recommendations are given for measuring dose in non-reference conditions. This COP is designed around the service that NPL provides and thus it does not require the range of different options presented in TRS483, such as generic correction factors for beam quality. This approach results in a significantly simpler, more concise and easier to follow protocol.
With the help of modern VMAT techniques, it is possible to effectively achieve highly conformal dose delivery which may provide an opportunity to escalate the dose to the tumour in this group of patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.