Herpes Simplex Virus Type 2 (HSV-2) is a common human pathogen that causes life-long illness. The US prevalence of HSV-2 infection is 11.9% for individuals between 15 and 49 years of age. Individuals with HSV-2 infection are more likely to contract and spread other sexually-transmitted infections. Eighty percent of individuals with HSV-2 are unaware of their infection, in part because of the social stigma associated with in-clinic testing for sexually-transmitted infections. We conducted an initial evaluation of a prototype smartphone-based serological lateral-flow immunoassay (LFA) for HSV-2 infection that uses strontium aluminate persistent luminescent nanoparticles (nanophosphors) as reporters. When applied to a test panel of 21 human plasma/serum samples varying in anti-HSV titer, the nanophosphor HSV-2 LFA had 96.7% sensitivity and 100% specificity for detection of HSV-2 infection. The sensitivity of the nanophosphor HSV-2 LFA was higher than that of commercially-available rapid HSV-2 assays tested with the same panel. Analysis of the iPhone nanophosphor HSV-2 LFA strip images with our custom smartphone app gave greater reproducibility compared to ImageJ analysis of strip images. The smartphone-based nanophosphor LFA technology shows promise for private self-testing for sexually-transmitted infections (STI).
Using microscopy and image analysis, we characterize binding of filamentous viral nanoparticles to a fibrous affinity matrix as models for reporter capture in a lateral flow assay (LFA). M13 bacteriophage (M13) displaying an in vivo-biotinylated peptide (AviTag) genetically fused to the M13 tail protein p3 are functionalized with fluorescent labels. We functionalize glass fiber LFA membranes with antibodies to M13, which primarily capture M13 on the major p8 coat proteins, or with avidin, which captures M13 at the biotin-functionalized tail, and compare orientational modes of reporter capture for the side- versus tip-binding recognition interactions. The number of captured M13 is greater for side-binding than for tip-binding, as expected from the number of recognition groups. Whereas two-thirds of side-bound M13 captured by an anti-M13 antibody bind immediately after colliding with the membrane, tip-bound M13 prominently exhibit three additional orientational modes that require M13 to reorient to enable binding. These results are consistent with the idea that the elongated M13 shape couples with the complex flow field in an open and disordered fibrous LFA membrane to enhance capture.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.