Hybrid procedures appear to have a low incidence of associated major AEs. PDA stent placement performed as a palliation of hypoplastic left heart syndrome (HLHS) or complex single/two ventricle patients may have a lower incidence of AEs if performed using a direct approach with surgical exposure rather than a percutaneous approach. Accurate definitions of these innovative procedures are required to facilitate prospective data collection.
Motor skills and neurodevelopment in infants with hypoplastic left heart syndrome (HLHS) who have undergone Hybrid Stage I palliation is unknown. The purpose of this study is to assess early neurodevelopment in infants with HLHS after Hybrid Stage I palliation. Developmental assessment was performed in HLHS infants who underwent Hybrid Stage I palliation at 2 and 4 months of age using the Test of Infant Motor Performance, and at 6 months of age, prior to undergoing the second staged surgery, using the Bayley Scales of Infant and Toddler Development, 3rd edition (Bayley-III). Results were compared to healthy control subjects and norm-referenced data. The HLHS group scored between -1 and -2 standard deviations (SD) below the mean at 2 months of age (p = 0.002), and within -1 SD of the mean, at 4 months of age (p = 0.0019), on the TIMP. Compared to the control group, composite motor skills were significantly lower at 6 months of age on the Bayley-III in the HLHS group (p = 0.0489), however, not significant for cognitive (p = 0.29) or language (p = 0.68). Percentile rank motor scores were 17 ± 20 % in the HLHS group compared to 85 ± 12 % for the healthy age-matched control group. Infants with HLHS who undergo Hybrid Stage I palliation score lower on standardized motor skill tests compared to healthy age-matched controls and the norm-referenced population. This suggests that infants with HLHS have poorer motor skill performance than typically developing infants at 6 months of age.
The Melody valve can be implanted at 24 mm in the stenotic/regurgitant bioprosthetic pulmonary, tricuspid, and aortic valve, dysfunctional right ventricle to pulmonary artery conduit, and the native right ventricular outflow tract, whereas the valve remains competent with only mild regurgitation.
With utilization of appropriate techniques and equipment, atrial septal interventions in HLHS can be performed successfully in virtually all patients. Complex atrial septal anatomy is technically challenging and has a higher incidence of procedural adverse events. In the majority of patients, standard BAS can be performed safely, and is usually the only intervention required to achieve adequate relief of atrial septal restriction until Comprehensive stage II palliation.
Stenting of complex aortic arch lesions can be performed safely and effectively with excellent, immediate, and midterm results. Patients with a weight below 10 kg or after Hybrid stage I palliation are at increased risk of adverse events. Stents can be placed across major arch vessels without compromising distal perfusion in otherwise normal vasculature.
In small children, MDCT is a feasible and promising method for assessing stent associated complications in the treatment of CHD. Cardiac surgeons and interventional cardiologists might rely on this imaging modality to plan specific interventions more precisely and to assess the results upon follow up.
This study aimed to assess the technical aspects of atrial septal defect (ASD) closure using the Amplatzer septal occluder (ASO) and the Gore Helex septal occluder (GHSO) for infants weighing less than 8 kg and to determine the safety, effectiveness, and near-to-intermediate-term outcome of the closure. The Mid-Atlantic Group of Interventional Cardiology Registry of percutaneous, transcatheter ASD closure procedures was reviewed for this analysis. Patients from 10 hospitals in the United States were included. The cohort for this report consisted of 68 patients weighing less than 8 kg (range, 2.3-7.8 kg; mean, 5.5 ± 1.6 kg) and ranging in age from 1 to 24 months (mean, 8.6 ± 4.7 months). The indications for ASD closure were failure to thrive, significant right heart enlargement, shunts otherwise thought to be hemodynamically significant, and poor overall clinical status. Devices were successfully implanted in 66 of the 68 infants (97.1 % procedural success rate). Five minor procedure-related complications occurred. At follow-up assessment, clinical status had improved significantly as measured by improved weight gain and decreased ventilator or oxygen dependence. All residual shunts spontaneously closed during the follow-up period. Six late deaths occurred, none of which were clearly device related. The ASO and GHSO can be safely and effectively implanted for ASD closure in infants weighing less than 8 kg. These procedures usually are successful and seldom complicated, resulting in significant clinical improvement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.