The medtronic melody® transcatheter pulmonary valve implanted at 24‐mm diameter—it works

Abstract: The Melody valve can be implanted at 24 mm in the stenotic/regurgitant bioprosthetic pulmonary, tricuspid, and aortic valve, dysfunctional right ventricle to pulmonary artery conduit, and the native right ventricular outflow tract, whereas the valve remains competent with only mild regurgitation.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
35
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 60 publications
(35 citation statements)
references
References 23 publications
0
35
0
Order By: Relevance
“…Obtaining additional information with ICE that may be difficult to evaluate by angiography, such as the presence of paravalvar leak, may also allow the interventionalist to address these issues immediately during the same procedure and prevent subsequent procedures. The use of ICE in Melody TPV implantation has been reported in isolated case report and case series [6,7], and, most recently, Awad et al [3] reported on the use of continuous ICE guidance during implantation of both the Melody and Edwards Sapien (Edwards Lifesciences, Irvine, CA) TPV. While anatomic and functional assessment of the pulmonary valve can be obtained easily by ICE [11,12], a comprehensive analysis of clinical utility in this population is lacking.…”
Section: Introductionmentioning
confidence: 97%
“…Obtaining additional information with ICE that may be difficult to evaluate by angiography, such as the presence of paravalvar leak, may also allow the interventionalist to address these issues immediately during the same procedure and prevent subsequent procedures. The use of ICE in Melody TPV implantation has been reported in isolated case report and case series [6,7], and, most recently, Awad et al [3] reported on the use of continuous ICE guidance during implantation of both the Melody and Edwards Sapien (Edwards Lifesciences, Irvine, CA) TPV. While anatomic and functional assessment of the pulmonary valve can be obtained easily by ICE [11,12], a comprehensive analysis of clinical utility in this population is lacking.…”
Section: Introductionmentioning
confidence: 97%
“…Image reproduced with the permission of Edwards Lifesciences. 22 mm, some have successfully used the device on a 24 mm balloon [47]. An alternative strategy is a recently-published hybrid technique.…”
Section: Pulmonic Valvementioning
confidence: 98%
“…the use of two Melody valves implanted in respective pulmonary arteries in a single patient; jailing and/or Russian doll techniques) [9,[15][16][17]. Cheatham et al showed that PPVI using a 24 mm balloon catheter for the deployment of the Melody valve was feasible, without impairment of valvular function (RVOT diameter of 26 mm) [18]. The SAPIEN valve diameters are 23, 26 and 29 mm, which makes it potentially more suitable for PPVI in large-diameter conduits and native outflow tracts (up to 27 mm) than the Melody valve, but the device is not widely available.…”
Section: Percutaneous Pulmonary Valve Implantation In Large Right Venmentioning
confidence: 99%