An endoAVF can be reliably created using a radiofrequency magnetic catheter-based system, without open surgery and with minimal complications. The endoAVF can be successfully used for hemodialysis and demonstrated high 12-month cumulative patencies. It may be a viable alternative option for achieving AVFs for hemodialysis patients in need of vascular access.
Background Early renal transplant failure necessitating a return to dialysis has been shown to be a poor prognostic factor for survival. Little is known about the outcome of patients with late transplant failure returning to dialysis. It was our clinical impression that late transplant failure (>2 months) carries an increased morbidity and mortality risk in patients returning to dialysis. Objective To determine whether patients with a failed renal transplant have an outcome different to those on dialysis who have never received a kidney transplant. Setting Peritoneal dialysis (PD) unit in a teaching hospital. Patients and Design All failed renal transplant patients (fTx) in the Toronto Hospital Peritoneal Dialysis program between 1989 and 1996 were identified. This cohort of 42 fTx patients was compared with a cohort of randomly selected never-transplanted PD patients (non-Tx). The PD program was selected because of the availability of well-documented patient archival material. The non-Tx group was matched for age and presence of diabetes. Data were collected until retransplantation, change of dialysis modality or center, death, or until June 1998. Results There was no difference at initiation of PD between groups in serum albumin, residual renal function, or mean serum parathyroid hormone level. The mean low-density lipoprotein level was significantly higher in the fTx cohort. The duration of dialysis before Tx in fTx patients accounted for the increased total length of dialysis in fTx (mean 15 months). However, post-Tx the duration of PD was similar for both groups (30.7 months for fTx vs 31.6 months for non-Tx). The fTx group had a considerably worse outcome than the non-Tx group. The time to first peritonitis, subsequent episodes of peritonitis, catheter change, or transfer to hemodialysis occurred at a much faster rate in fTx patients. The most dramatic difference was in survival. There were 3 deaths in the non-Tx group and 12 in the fTx group ( p < 0.01). The mean age at time of death in the fTx group was 47.5 years. Deaths were due mainly to gram-negative peritonitis and cardiovascular disease. Conclusions W e conclude that late failed renal transplant patients starting dialysis are at increased risk of complications and have strikingly higher mortality rates than non-Tx patients. A previously failed kidney transplant can be considered an adverse prognostic factor for patients commencing PD; these patients need to be closely monitored. Although this study was limited to PD patients, the same principles likely apply to fTx patients returning to any form of renal replacement therapy.
Background: Small randomized trials demonstrated that a lower compared with higher dialysate temperature reduced the average drop in intradialytic blood pressure. Some observational studies demonstrated that a lower compared with higher dialysate temperature was associated with a lower risk of all-cause mortality and cardiovascular mortality. There is now the need for a large randomized trial that compares the effect of a low vs high dialysate temperature on major cardiovascular outcomes. Objective: The purpose of this study is to test the effect of outpatient hemodialysis centers randomized to (1) a personalized temperature-reduced dialysate protocol or (2) a standard-temperature dialysate protocol for 4 years on cardiovascular-related death and hospitalizations. Design: The design of the study is a pragmatic, registry-based, open-label, cluster randomized controlled trial. Setting: Hemodialysis centers in Ontario, Canada, were randomized on February 1, 2017, for a trial start date of April 3, 2017, and end date of March 31, 2021. Participants: In total, 84 hemodialysis centers will care for approximately 15 500 patients and provide over 4 million dialysis sessions over a 4-year follow-up. Intervention: Hemodialysis centers were randomized (1:1) to provide (1) a personalized temperature-reduced dialysate protocol or (2) a standard-temperature dialysate protocol of 36.5°C. For the personalized protocol, nurses set the dialysate temperature between 0.5°C and 0.9°C below the patient’s predialysis body temperature for each dialysis session, to a minimum dialysate temperature of 35.5°C. Primary outcome: A composite of cardiovascular-related death or major cardiovascular-related hospitalization (a hospital admission with myocardial infarction, congestive heart failure, or ischemic stroke) captured in Ontario health care administrative databases. Planned primary analysis: The primary analysis will follow an intent-to-treat approach. The hazard ratio of time-to-first event will be estimated from a Cox model. Within-center correlation will be considered using a robust sandwich estimator. Observation time will be censored on the trial end date or when patients die from a noncardiovascular event. Trial Registration: www.clinicaltrials.gov ; identifier: NCT02628366.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.