A hemodynamic Lab-on-a-chip system was developed in this study. This system has two unique features: (1) it consists of a microfluidic network with an array of endothelial cell seeding sites for testing them under multiple conditions, and (2) the flow rate and the frequency of the culture medium in the microchannel are controlled by a pulsation free pump to mimic the flow profile of the blood in the blood vessel under different physiological conditions. The investigated physiological conditions were: (1) the resting condition in a normal shear stress of 15 dyne cm(-2) with a normal heart rate of 70 bpm, (2) an exhaustive exercise condition with a high shear stress of 30 dyne cm(-2) and a fast heart rate of 140 bpm, and (3) a constant high shear stress of 30 dyne cm(-2). Two chemical conditions were investigated (10 mM and 20 mM glucose) to mimic hyperglycemic conditions in diabetes patients. The effects of various shear stresses either alone or in combination with different glucose concentrations on endothelial cells were examined using the developed hemodynamic Lab-on-a-chip system by assessing two parameters. One is the intracellular level of reactive oxygen species (ROS) determined by a fluorescent probe, H(2)DCFDA. Another is the mitochondrial morphology revealed with a fluorescent dye, MitoTracker Green FM. The results showed that ROS level was elevated nearly 4-fold after 60 min of exhaustive exercise. We found that the pulsatile nature of the fluid was the determination factor for causing ROS generation in the cells as almost no increase of ROS was detected in the constant shear stress condition. Similarly, much higher level of ROS was detected when 10 mM glucose was applied to the cells under normal or high pulsatile shear stresses compared with under a static condition. These results suggest that it is necessary to use pulsatile shear stress to represent the physiological conditions of the blood flow, and demonstrate the advantage of utilizing this newly developed hemodynamic Lab-on-a-chip system over the conventional non-pulsatile system in the future shear stress related studies.
This Letter presents a reconfigurable optical diffraction grating using multiphase droplets on a microfluidic chip. The uniform and evenly spaced circular droplets are generated by continuously dispersing two immiscible liquids into a T junction to produce plugs, which are then transformed into a circular shape at a sudden expansion of the microchannel. In experiments, the droplet grating shows a detection limit of~6:3 × 10 −5 when used as an optofluidic refractometer and produces different colors as a color filter. Such a grating has the advantages of high stability and wide tunability in droplet size, grating period, and refractive index, making it promising for biochemical and biomaterial applications.
Bacterial cellulose (BC) is a biocompatible material with high purity and robust mechanical strength used to fabricate desirable scaffolds for 3D cell culture and wound healing. However, the chemical resistance of BC and its insolubility in the majority of solutions make it difficult to manipulate using standard chemical methods. In this study, a microfluidic process is developed to produce hollow BC microspheres with desirable internal structures and morphology. Microfluidics is used to generate a core-shell structured microparticle with an alginate core and agarose shell as a template to encapsulate Gluconacetobacter xylinus for long-term static culture. G. xylinus then secretes BC, which becomes entangled within the shell of the structured hydrogel microparticles and forms BC microspheres. The removal of the hydrogel template via thermal-chemical treatments yields robust BC microspheres exhibiting a hollow morphology. These hollow microspheres spontaneously assemble as functional units to form a novel injectable scaffold. In vitro, a highly porous scaffold is created to enable effective 3D cell culture with a high cell proliferation rate and better depth distribution. In vivo, this injectable scaffold facilitates tissue regeneration, resulting in rapid wound-healing in a Sprague Dawley rat skin model.
To better understand how hyperglycemia induces endothelial cell dysfunction under the diabetic conditions, a hemodynamic microfluidic chip system was developed. The system combines a caspase-3-based fluorescence resonance energy transfer (FRET) biosensor cell line which can detect endothelial cell apoptosis in real-time, post-treatment effect and with a limited cell sample, by using a microfluidic chip which can mimic the physiological pulsatile flow profile in the blood vessel. The caspase-3-based FRET biosensor endothelial cell line (HUVEC-C3) can produce a FRET-based sensor protein capable of probing caspase-3 activation. When the endothelial cells undergo apoptosis, the color of the sensor cells changes from green to blue, thus sensing apoptosis. A double-labeling fluorescent technique (yo pro-1 and propidium iodide) was used to validate the findings revealed by the FRET-based caspase sensor. The results show high rates of apoptosis and necrosis of endothelial cells when high glucose concentration was applied in our hemodynamic microfluidic chip combined with an exhaustive pulsatile flow profile. The two apoptosis detection techniques (fluorescent method and FRET biosensor) are comparable; but FRET biosensor offers more advantages such as real-time observation and a convenient operating process to generate more accurate and reliable data. Furthermore, the activation of the FRET biosensor also confirms the endothelial cell apoptosis induced by the abnormal pulsatile shear stress and high glucose concentration is through caspase-3 pathway. A 12% apoptotic rate (nearly a 4-fold increase compared to the static condition) was observed when the endothelial cells were exposed to a high glucose concentration of 20 mM under 2 h exhaustive pulsatile shear stress of 30 dyne cm(-2) and followed with another 10 h normal pulsatile shear stress of 15 dyne cm(-2). Therefore, the most important finding of this study is to develop a novel endothelial cell apoptosis detection method, which combines the microfluidic chip system and FRET biosensor. This finding may provide new insight into how glucose causes endothelial cell dysfunction, which is the major cause of diabetes-derived complications.
Four unusual cyclopeptides, zelkovamycins B–E (1–4), were isolated from an endophytic Kitasatospora sp. Zelkovamycin B was featured by an unprecedented 3-methyl-5-hydroxypyrrolidine-2,4-dione ring system linked to the cyclopeptide skeleton. Their structures and full configurations were established by spectroscopic analysis, Marfey’s method, and NMR calculations. A plausible biosynthetic pathway for zelkovamycins was proposed based on gene cluster analysis. Zelkovamycin E displayed potent inhibitory activity against H1N1 influenza A virus.
In this work, flavonoid fraction from the leaves of Crataegus pinnatifida was separated into its seven main constituents using a combination of HSCCC coupled with pre-HPLC. In the first step, the total flavonoid extract was subjected to HSCCC with a two-solvent system of chloroform/methanol/water/n-butanol (4:3:2:1.5, v/v), yielding four pure compounds, namely (–)-epicatechin (1), quercetin-3-O-(2,6-di-α-l-rhamnopyranosyl)-β-d-galactopyranoside (2), 4′′-O-glucosylvitexin (3) and 2′′-O-rhamnosylvitexin (4) as well as a mixture of three further flavonoids. An extrusion mode was used to rapidly separate quercetin-3-O-(2,6-di-α-l-rhamnopyranosyl)-β-d-galactopyranoside with a big KD-value. In the second step, the mixture that resulted from HSCCC was separated by pre-HPLC, resulting in three pure compounds including: vitexin (5), hyperoside (6) and isoquercitrin (7). The purities of the isolated compounds were established to be over 98%, as determined by HPLC. The structures of these seven flavonoids were elucidated by ESI-MS and NMR spectroscopic analyses.
Bacteriophages are considered as attractive indicators for determining drinking water quality since its concentration is strongly correlated with virus concentrations in water samples. Previously, bacteriophage detection was based on a plague assay that required a complicated labelling technique and a time-consuming culture assay. Here, for the first time, a label-free bacteriophage detection is reported by using droplet optofluidic imaging, which uses host-cell-containing microdroplets as reaction carriers for bacteriophage infection due to a higher contact ratio. The optofluidic imaging is based on the effective refractive index changes in the microdroplet correlated with the growth rate of the infected host cells, which is highly sensitive, i.e. can detect one E. coli cell. The droplet optofluidic system is not only used in drinking water quality monitoring, but also has high potential applications for pathogenic bacteria detection in clinical diagnosis and food industry.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.