MicroRNAs (miRNAs) are small non-coding RNAs (typically consisting of 18–25 nucleotides) that negatively control expression of target genes at the post-transcriptional level. Owing to the biological significance of miRNAs, miRTarBase was developed to provide comprehensive information on experimentally validated miRNA–target interactions (MTIs). To date, the database has accumulated >13,404 validated MTIs from 11,021 articles from manual curations. In this update, a text-mining system was incorporated to enhance the recognition of MTI-related articles by adopting a scoring system. In addition, a variety of biological databases were integrated to provide information on the regulatory network of miRNAs and its expression in blood. Not only targets of miRNAs but also regulators of miRNAs are provided to users for investigating the up- and downstream regulations of miRNAs. Moreover, the number of MTIs with high-throughput experimental evidence increased remarkably (validated by CLIP-seq technology). In conclusion, these improvements promote the miRTarBase as one of the most comprehensively annotated and experimentally validated miRNA–target interaction databases. The updated version of miRTarBase is now available at http://miRTarBase.cuhk.edu.cn/.
A high-precision camera intrinsic parameters calibration method based on concentric circles was proposed. Different from Zhang’s method, its feature points are the centers of concentric circles. First, the collinearity of the projection of the center of concentric circles and the centers of two ellipses which are imaged from the concentric circles was proved. Subsequently, a straight line passing through the center of concentric circles was determined with four tangent lines of concentric circles. Finally, the projection of the center of concentric circles was extracted with the intersection of the straight line and the line determined by the two ellipse centers. Simulation and physical experiments are carried out to analyze the factors affecting the accuracy of circle center coordinate extraction and the results show that the accuracy of the proposed method is higher. On this basis, several key parameters of the calibration target design are determined through simulation experiments and then the calibration target is printed to calibrate a binocular system. The results show that the total reprojection error of the left camera is reduced by 17.66% and that of the right camera is reduced by 21.58% compared with those of Zhang’s method. Therefore, the proposed calibration method has higher accuracy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.