BACKGROUND: Conventional sputum suctioning is a routine clinical practice, but complications may arise from the blind manipulation of the catheter. Recently, a visual sputum suctioning system (VSSS) was developed, and we tested this new system in a laboratory setting. METHODS: We used coagulant concentrations of 1.5% and 3.0% to simulate mucus and sputum. Conventional singlelumen and triple-lumen catheters were inserted separately into a beaker for sputum suctioning (15 s, 200 mm Hg). A micro-imaging fiber was integrated into the triple-lumen catheter to create the VSSS. The single-lumen catheter and the VSSS were inserted separately into the mouth cavity, the nasal cavity, the tracheostomy tube, and the endotracheal tube of a human analog model for further comparisons. RESULTS: As the suction channel of the triple-lumen catheter was reduced by 46.8%, the amount of simulant it suctioned was significantly less than that suctioned by the single-lumen catheter. However, under real-time guidance, the VSSS suctioned more simulant than the conventional single-lumen catheter in the human analog model. CONCLUSION: Sputum suctioning with the VSSS was feasible. Because of its real-time imaging guidance, the efficiency of the VSSS procedure was greater than that of the conventional single-lumen catheter. Therefore, this system may provide a new platform for sputum suctioning.
PurposeTo assess the feasibility and safety of imaging canine peripheral airways (<1 mm) with an experimental micro-imaging fiber optic bronchoscope.MethodsTwenty healthy dogs were scoped with a micro-imaging fiber optic bronchoscope (0.8 mm outer diameter). Images at various levels of the bronchioles, mucosal color, and tracheal secretions were recorded. The apparatus was stopped once it was difficult to insert. CT imaging was performed simultaneously to monitor progression. The safety of the device was evaluated by monitoring heart rate (HR), respiratory rate (RR), mean artery pressure (MAP), peripheral oxygen saturation (SpO2) and arterial blood gases (partial pressure of arterial carbon-dioxide, PaCO2, partial pressure of arterial oxygen, PaO2, and blood pH).Results(1) According to the CT scan, the micro-imaging fiber was able to access the peripheral airways (<1 mm) in canines. (2) There was no significant change in the values of HR, MAP, pH and PaCO2 during the procedure (P>0.05). Comparing pre-manipulation and post-manipulation values, SpO2 (F = 13.06, P<0.05) and PaO2 (F = 3.01, P = 0.01) were decreased, whereas RR (F = 3.85, P<0.05) was elevated during the manipulation. (3) Self-limited bleeding was observed in one dog; severe bleeding or other complications did not occur.ConclusionAlthough the new apparatus had little effect on SpO2, PaO2 and RR, it can probe into small peripheral airways (<1 mm), which may provide a new platform for the early diagnosis of bronchiolar diseases.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.