High-frequency electric field welding-induced tissue fusion has been explored as an advanced surgical method for intestinal anastomoses; however, intrinsic mechanisms remain unclear. The aim of this study was to investigate microcosmic changes of collagen within the fusion area, with various parameters. Ex vivo small intestine was fused with mucosa–mucosa. Four levels of compressive pressure (100 kPa, 150 kPa, 200 kPa, 250 kPa) were applied for 10s in order to fuse the colons under a power level of 140W. Then, collagen fibers of the fusion area were examined by fibrillar collagen alignment and TEM. Three levels of power (90 W, 110 W, 140 W) and three levels of time (5 s, 10 s, 20 s) were applied in order to fuse colons at 250kPa, and then collagen within the fusion area was examined by Raman spectroscopy. Fibrillar collagen alignment analysis showed that with the increase in compression pressure, alignment of the collagen in the fusion area gradually increased, and the arrangement of collagen fibers tended to be consistent, which was conducive to the adhesion of collagen fibers. TEM showed that pressure changed the distribution and morphology of collagen fibers. Raman spectroscopy showed that increased power and time within a certain range contributed to collagen cross linking. Peak positions of amide I band and amide III band changed. These results suggested that higher power and a longer amount of time resulted in a decrease in non-reducible cross links and an increase in reducible cross links. Compression pressure, power, and time can affect the state of collagen, but the mechanisms are different. Compressive pressure affected the state of collagen by changing its orientation; power and time denatured collagen by increasing temperature and improved the reducible cross linking of collagen to promote tissue fusion.
The inductor-based and capacitor-free bipolar pulse converter can be applied to electric vehicle charging and realize an efficient and reliable charging-control strategy. Inductor-based converters can avoid the converter failure caused by the failure of energy storage capacitors and improve the reliability. An overvoltage protection scheme based on active clamping topology is used to protect this converter when the load impedance is too large. This overvoltage protection can take effect in an extremely short time (~50 ns) with little energy wasted. Furthermore, mathematical analyses of the proposed topology are presented and simulations based on LTspice are made, showing the feasibility and reliability of this circuit. Moreover, calculation of the power loss on MOSFETs is presented. A 201 W prototype converter with an efficiency of 83% is presented, and experimental results show that the converter can work reliably. This manuscript also proves the feasibility and application prospect of using this current-source-based converter for EV charging.
Current source inverters (CSIs) use inductors as the major component to store energy. Compared with voltage source inverters (VSIs), CSIs have two advantages: 1. They can avoid the converter failure caused by capacitor failures, and 2. The load current does not increase with load mutation or even short-circuit failure. Therefore, CSIs can be a promising technology for EV charging. However, the waveforms, parameter design procedure, and power efficiency are still unclear. Therefore, it is unclear if CSIs are suitable for EV chargers. This article derives the closed-loop equations of the critical components, including the inductor current waveforms and the voltage ripple. Especially, the load over-voltage phenomenon is derived and verified to further ensure the reliability of the CSI system. Based on the derived equations and reliability requirements, the parameter design procedure is proposed. The power efficiency of both the Si- and SiC-based converters are derived and compared to remove the barrier of applying CSIs in EV chargers in the industry. Our simulations and experiments verify the correctness of the system modeling, over-voltage phenomenon, and power efficiency. All the simulation files (using PLECS) and calculation files (using MATLAB) are attached for the readers to verify and/or further modify.
The success rate of the electrosurgical high-frequency electric field welding technique lies in reasonable control of the welding time. However, the final impedance value used to control the welding time varies due to differences in tissue size and the welding method during the welding process. This study aims to introduce a new reference indicator not limited by impedance size from dynamic impedance to achieve an adequate weld strength with minimal thermal damage, providing feedback on the tissue welding effect in medical power supplies. End-to-end anastomosis experiments were conducted with porcine small intestine tissue under seven levels of compression pressure. The dynamic impedance changes were analyzed, combined with compression pressure, temperature, moisture, and collagen during welding. The welding process was divided into three stages according to the dynamic impedance, with impedance decreasing in Period Ⅰ and impedance increasing in Period Ⅲ. Period Ⅲ was the key to high-strength connections due to water evaporation and collagen reorganization. The dynamic impedance ratio is defined as the final impedance divided by the minimum impedance, and successful welding would be predicted when detecting the dynamic impedance ratio over 4 (n = 70, p < 0.001). Dynamic impedance monitoring can be used as a macroscopic real-time prediction of the anastomosis effect.
Background: Tissue welding is an electrosurgical technique that can fuse tissue for small intestine anastomosis. However, limited knowledge exists on its application in mucosa-mucosa end-to-end anastomosis. This study investigates the effects of initial compression pressure, out-put power, and duration time on anastomosis strength ex vivo in mucosa-mucosa end-to-end anastomosis.Methods:Ex vivo porcine bowel segments were used to create 140 mucosa-mucosa end-to-end fusions. Different experimental parameters were employed for fusion, including initial com-pression pressure (50kPa–400 kPa), output power (90W, 110W, and 140W), and fusion time (5, 10, 15, 20 s). The fusion quality was measured by burst pressure and optical microscopes.Results: The best fusion quality was achieved with an initial compressive pressure between 200 and 250 kPa, an output power of 140W, and a fusion time of 15 s. However, an increase in output power and duration time resulted in a wider range of thermal damage. There was no significant difference between the burst pressure at 15 and 20 s (p > 0.05). However, a substantial increase in thermal damage was observed with longer fusion times of 15 and 20 s (p < 0.05).Conclusion: The best fusion quality for mucosa-mucosa end-to-end anastomosis ex vivo is achieved when the initial compressive pressure is between 200 and 250 kPa, the output power is approximately 140W, and the fusion time is approximately 15 s. These findings can serve as a valuable theoretical foundation and technical guidance for conducting animal experiments in vivo and subsequent tissue regeneration.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.