In clinical surgery, high frequency electric welding is routinely utilized to seal and fuse soft tissues. This procedure denatures collagen by electrothermal coupling, resulting in the formation of new molecular crosslinks. It is critical to understand the temperature distribution and collagen structure changes during welding in order to prevent thermal damage caused by heat generated during welding. In this study, a method combining optical measurement and simulation was presented to evaluate the temperature distribution of vascular tissue during welding, with a fitting degree larger than 97% between simulation findings and measured data. Integrating temperature distribution data, strength test data, and Raman spectrum data, it is discovered that optimal parameters exist in the welding process that may effectively prevent thermal damage while assuring welding strength.
Wound healing is a complicated process for maintaining skin integrity after injury, for which electrical stimulations (ES) are ascribed to promote wound healing by facilitating cell migration. Time-shortening of the stimulation treatment from current hours to minutes for efficient wound healing but free of cell damage in return, is however rather a challenge. Here, a novel mechanism of ultrashort pulse electric filed (PEF), microsecond PEF at higher voltage, is proposed and realized to promote wound healing under a much short time (seconds) for the total treatment. We revealed that microsecond PEF regulated actin cytoskeleton reorganization and focal adhesion turnover, promoting fibroblasts migration in 2D cell cultures under the pulse stimulation. This accelerated fibroblast migration was accompanied by the mutual promotion with extracellular matrix (ECM) alignment in 3D microenvironments, which cooperatively benefit the eventual wound healing, and these findings were further confirmed by the enhanced skin wound healing in a classic mouse model. Additionally, we coined an actin- and collagen-dependent mechanism of microsecond PEF-mediated wound healing. The quantitative mechanism proposed here for our novel microsecond pulse electric field (μsPEF) methodology orients the new practical electric treatment in a wide range of biomedical applications, such as wound healing, regenerative medicine, and tissue engineering.
High-frequency electric field welding-induced tissue fusion has been explored as an advanced surgical method for intestinal anastomoses; however, intrinsic mechanisms remain unclear. The aim of this study was to investigate microcosmic changes of collagen within the fusion area, with various parameters. Ex vivo small intestine was fused with mucosa–mucosa. Four levels of compressive pressure (100 kPa, 150 kPa, 200 kPa, 250 kPa) were applied for 10s in order to fuse the colons under a power level of 140W. Then, collagen fibers of the fusion area were examined by fibrillar collagen alignment and TEM. Three levels of power (90 W, 110 W, 140 W) and three levels of time (5 s, 10 s, 20 s) were applied in order to fuse colons at 250kPa, and then collagen within the fusion area was examined by Raman spectroscopy. Fibrillar collagen alignment analysis showed that with the increase in compression pressure, alignment of the collagen in the fusion area gradually increased, and the arrangement of collagen fibers tended to be consistent, which was conducive to the adhesion of collagen fibers. TEM showed that pressure changed the distribution and morphology of collagen fibers. Raman spectroscopy showed that increased power and time within a certain range contributed to collagen cross linking. Peak positions of amide I band and amide III band changed. These results suggested that higher power and a longer amount of time resulted in a decrease in non-reducible cross links and an increase in reducible cross links. Compression pressure, power, and time can affect the state of collagen, but the mechanisms are different. Compressive pressure affected the state of collagen by changing its orientation; power and time denatured collagen by increasing temperature and improved the reducible cross linking of collagen to promote tissue fusion.
The radiofrequency-induced intestine fusion has been widely studied as an alternative for traditional suture in surgery, but fusion quality cannot be evaluated directly. Impedance measurement can evaluate fusion quality, but the relation between impedance and the fusion quality needs optimization for best results. The present study reports the optimum resistance of small intestine fusion. As the feedback signal, resistance was considered the indicator of the fusion completion for the device design of intestine fusion and an in-depth study of microstructure change. A self-design pulse source was used for the small intestine fusion with adjustable voltage, duty ratio, frequency and output time. A frequency of 440 kHz was set, whereas voltage, output time and compression pressure (CP) of the small intestine were independent variables. Different conditions of voltage, CP and time were investigated for achieving the highest burst pressure (BP) measured with a pressure gauge and a peristaltic pump. Each parameter of the equivalent circuit model was calculated by an experimental waveform. Hematoxylin–eosin staining of fusion samples was used for assessing the quality of fusion. The real-time current was measured and recorded during the fusion for the calculation of capacitance and resistance. The highest BP of 38.9 mmHg was achieved with a CP of 900 kPa, a voltage of 50 V and a time of 5 s. Finally, an optimum extracellular resistance range of 61.0–86.2 Ω was found as the optimum resistance for the end of fusion, thus indicating automatic fusion with the best fusion quality.
The success rate of the electrosurgical high-frequency electric field welding technique lies in reasonable control of the welding time. However, the final impedance value used to control the welding time varies due to differences in tissue size and the welding method during the welding process. This study aims to introduce a new reference indicator not limited by impedance size from dynamic impedance to achieve an adequate weld strength with minimal thermal damage, providing feedback on the tissue welding effect in medical power supplies. End-to-end anastomosis experiments were conducted with porcine small intestine tissue under seven levels of compression pressure. The dynamic impedance changes were analyzed, combined with compression pressure, temperature, moisture, and collagen during welding. The welding process was divided into three stages according to the dynamic impedance, with impedance decreasing in Period Ⅰ and impedance increasing in Period Ⅲ. Period Ⅲ was the key to high-strength connections due to water evaporation and collagen reorganization. The dynamic impedance ratio is defined as the final impedance divided by the minimum impedance, and successful welding would be predicted when detecting the dynamic impedance ratio over 4 (n = 70, p < 0.001). Dynamic impedance monitoring can be used as a macroscopic real-time prediction of the anastomosis effect.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.