An optimal electrode position and interventricular (VV) delay in cardiac resynchronization therapy (CRT) improves its success. However, the precise quantification of cardiac dyssynchrony and magnitude of resynchronization achieved by biventricular (BiV) pacing therapy with mechanical optimization strategies based on computational models remain scant. The maximum circumferential uniformity ratio estimate (CURE) was used here as mechanical optimization index, which was automatically computed for 6 different electrode positions based on a three-dimensional electromechanical canine model of heart failure (HF) caused by complete left bundle branch block (CLBBB). VV delay timing was adjusted accordingly. The heart excitation propagation was simulated with a monodomain model. The quantification of mechanical intra- and interventricular asynchrony was then investigated with eight-node isoparametric element method. The results showed that (i) the optimal pacing location from maximal CURE of 0.8516 was found at the left ventricle (LV) lateral wall near the equator site with a VV delay of 60 ms, in accordance with current clinical studies, (ii) compared with electrical optimization strategy of E
RMS, the LV synchronous contraction and the hemodynamics improved more with mechanical optimization strategy. Therefore, measures of mechanical dyssynchrony improve the sensitivity and specificity of predicting responders more. The model was subject to validation in future clinical studies.
CVD (cardiovascular disease) is one of the biggest threats to human beings nowadays. An early and quantitative diagnosis of CVD is important in extending lifespan and improving people's life quality. Coronary artery stenosis can prevent CVD. To diagnose the degree of stenosis, the inner diameter of coronary artery needs to be measured. To achieve such measurement, the coronary artery is segmented by using a method that is based on morphology and the continuity between computed tomography image slices. A centerline extraction method based on mechanical simulation is proposed. This centerline extraction method can figure out a basic framework of the coronary artery by simulating pixel dots of the artery image into mass points. Such mass points have tensile forces, with which the outer pixel dots can be drawn to the center. Subsequently, the centerline of the coronary artery can be outlined by using the local line-fitting method. Finally, the nearest point method is adopted to measure the inner diameter. Experimental results showed that the methods proposed in this paper can precisely extract the centerline of the coronary artery and can accurately measure its inner diameter, thereby providing a basis for quantitative diagnosis of coronary artery stenosis.
Myocardial perfusion abnormalities are the first sign of the ischemic cascade in the development of coronary artery disease (CAD). Thus, the early detection of myocardial perfusion abnormalities is significant for the prevention of CAD. Recently, a novel noninvasive method named Cardiodynamicsgram (CDG) has been proposed for early detection of CAD. This study aims to evaluate the predictive value of CDG in myocardial perfusion abnormalities for suspected ischemic heart disease. In the study, 86 suspected patients were enrolled. Standard 12-lead ECG and CDG were performed simultaneously before single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). Diagnostic accuracy of CDG for myocardial perfusion abnormalities detection is assessed using SPECT MPI as the reference standard. Of these 86 suspected patients, 37 patients were positive in CDG, 49 patients were negative in CDG. Diagnostic accuracy of CDG at presentation for myocardial perfusion abnormalities was 84.9%, sensitivity 84.0%, and specificity 89.4%. Furthermore, of the 10 patients whose SPECT MPI results are reverse redistribution, 9 patients were positive in CDG. Underlying causes of false positive CDG findings included the factors that can change the stability of cardiac electrical conduction and measurement noise. Myocardial remodeling in patients with old myocardial infarction might be the major cause of false negative findings. Results show a good consistency between the CDG and SPECT MPI in evaluating myocardial perfusion abnormalities. It suggests that CDG might be used as a cost-effective tool for assessing the myocardial perfusion abnormalities in the clinic.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.