A high electrode-to-electrode reproducibility of the emf response of solid contact ion-selective electrodes (SC-ISEs) requires a precise control of the phase boundary potential between the ion-selective membrane (ISM) and the underlying electron conductor. To achieve this, we introduced previously ionophore-free ion exchanger membranes doped with a well controlled ratio of oxidized and reduced species of a redox couple as redox buffer and used them to make SC-ISEs that exhibited highly reproducible electrode-to-electrode potentials. Unfortunately, ionophores were found to promote the loss of insufficiently lipophilic species from the ionophore-doped ISMs into aqueous samples. Here we report on an improved redox buffer platform based on equimolar amounts of the much less hydrophilic Co(III) and Co(II) complexes of 4,4'-dinonyl-2,2'-bipyridyl, which makes it possible to extend the redox buffer approach to ionophore-based ISEs. For example, K(+)-selective electrodes based on the ionophore valinomycin exhibit electrode-to-electrode standard deviations as low as 0.7 mV after exposure of freshly prepared electrodes for 1 h to aqueous solutions. Exposure of freshly prepared ISE membranes to humidity prior to their first contact to electrolyte solution minimizes the initial (reproducible) emf drift. This redox buffer has also been successfully applied to sodium, potassium, calcium, hydrogen, and carbonate ion-selective electrodes, which all exhibit the high selectivity over interfering ions as expected for ionophore-doped ISE membranes.
Solid contact ion-selective electrodes (ISEs) typically have an intermediate layer between the ion-selective membrane and the underlying solid electron conductor that is designed to reduce the irreproducibility and instability of the measured electromotive force (emf). Nevertheless, the electrode-to-electrode reproducibility of the emf of current solid contact ISEs is widely considered to be unsatisfactory. To address this problem, we report here a new method of constructing this intermediate layer based on the lipophilic redox buffer consisting of the Co(III) and Co(II) complexes of 1,10-phenanthroline ([Co(phen)3](3+/2+)) paired with tetrakis(pentafluorophenyl)borate as counterion. The resulting electrodes exhibit emf values with an electrode-to-electrode standard deviation as low as 1.7 mV after conditioning of freshly prepared electrodes for 1 h. While many prior examples of solid contact ISEs also used intermediate layers that contained redox active species, the selection of a balanced ratio of the reduced and oxidized species has typically been difficult and was often ignored, contributing to the emf irreproducibility. The ease of the control of the [Co(phen)3](3+)/[Co(phen)3](2+) ratio explains the high emf reproducibility, as confirmed by the emf decrease of 58 mV per 10-fold increase in the ratio of the reduced and oxidized redox buffer species. Use of a gold electrode modified with a self-assembled 1-hexanethiol monolayer as underlying electron conductor suppresses the formation of a water layer and results in an electrode-to-electrode standard deviation of E° of 1.0 mV after 2 weeks of exposure to KCl solution.
This paper presents a fully implantable 100-channel neural interface IC for neural activity monitoring. It contains 100-channel analog recording front-ends, 10 multiplexing successive approximation register ADCs, digital control modules and power management circuits. A dual sample-and-hold architecture is proposed, which extends the sampling time of the ADC and reduces the average power per channel by more than 50% compared to the conventional multiplexing neural recording system. A neural amplifier (NA) with current-reuse technique and weak inversion operation is demonstrated, consuming 800 nA under 1-V supply while achieving an input-referred noise of 4.0 µVrms in a 8-kHz bandwidth and a NEF of 1.9 for the whole analog recording chain. The measured frequency response of the analog front-end has a high-pass cutoff frequency from sub-1 Hz to 248 Hz and a low-pass cutoff frequency from 432 Hz to 5.1 kHz, which can be configured to record neural spikes and local field potentials simultaneously or separately. The whole system was fabricated in a 0.18-µm standard CMOS process and operates under 1 V for analog blocks and ADC, and 1.8 V for digital modules. The number of active recording channels is programmable and the digital output data rate changes accordingly, leading to high system power efficiency. The overall 100-channel interface IC consumes 1.16-mW total power, making it the optimum solution for multi-channel neural recording systems. Index Terms-Multi-channel neural recording system, biomedical application, high power efficiency, power and area trade-off, dual S/H, low-noise neural amplifier, current reuse, NEF, SAR ADC, capacitor-less LDO I. INTRODUCTION imultaneous recording of neuropotentials from the brain over a large number of electrodes provides an effective Manuscript received September 28, 2012.
Individuals with tetraplegia lack independent mobility, making them highly dependent on others to move from one place to another. Here, we describe how two macaques were able to use a wireless integrated system to control a robotic platform, over which they were sitting, to achieve independent mobility using the neuronal activity in their motor cortices. The activity of populations of single neurons was recorded using multiple electrode arrays implanted in the arm region of primary motor cortex, and decoded to achieve brain control of the platform. We found that free-running brain control of the platform (which was not equipped with any machine intelligence) was fast and accurate, resembling the performance achieved using joystick control. The decoding algorithms can be trained in the absence of joystick movements, as would be required for use by tetraplegic individuals, demonstrating that the non-human primate model is a good pre-clinical model for developing such a cortically-controlled movement prosthetic. Interestingly, we found that the response properties of some neurons differed greatly depending on the mode of control (joystick or brain control), suggesting different roles for these neurons in encoding movement intention and movement execution. These results demonstrate that independent mobility can be achieved without first training on prescribed motor movements, opening the door for the implementation of this technology in persons with tetraplegia.
Monitoring blood flow rate inside prosthetic vascular grafts enables an early detection of the graft degradation, followed by the timely intervention and prevention of the graft failure. This paper presents an inductively powered implantable blood flow sensor microsystem with bidirectional telemetry. The microsystem integrates silicon nanowire (SiNW) sensors with tunable piezoresistivity, an ultralow-power application-specific integrated circuit (ASIC), and two miniature coils that are coupled with a larger coil in an external monitoring unit to form a passive wireless link. Operating at 13.56-MHz carrier frequency, the implantable microsystem receives power and command from the external unit and backscatters digitized sensor readout through the coupling coils. The ASIC fabricated in 0.18-μm CMOS process occupies an active area of 1.5 × 1.78 mm (2) and consumes 21.6 μW only. The sensors based on the SiNW and diaphragm structure provide a gauge factor higher than 300 when a small negative tuning voltage (-0.5-0 V) is applied. The measured performance of the pressure sensor and ASIC has demonstrated 0.176 mmHg/√Hz sensing resolution.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.