A highly sensitive ultra-high-performance liquid chromatographic–tandem mass spectrometry (UPLC/MS/MS) method was developed for the quantification of the synthetic peptide drug of exenatide in monkey plasma. Sample preparation was carried out by solid-phase extraction (SPE), and bivalirudin was used as the internal standard (IS). An excellent chromatographic separation was obtained on a reversed-phase C18 column with a gradient elution. Detection utilized a Qtrap 5500 system operated in the positive ion mode with multiple reaction monitoring (MRM). The proposed method was validated by assessing the specificity, linearity, intra- and inter-day precision and accuracy, recovery, and stability. The method resulted in a linear calibration range of 0.10–30 ng/mL, extracting with only 50 μL monkey plasma aliquots. The intra- and inter-day precisions (as relative standard deviation) were less than 7.5% and 9.6%, respectively. The method could be successfully utilized for the pharmacokinetic study of exenatide in monkeys following a single subcutaneous injection of Byetta.
This approach accelerated the quantification, reduced the costs and provided an alternative in case of lacking the special antigen to denosumab or a RANKL-biotinylated reagent.
A stable HMG-CoA reductase (HMGR) reaction in vitro was developed by a sensitive, selective and precise liquid chromatography–tandem mass spectrometry (LC–MS/MS) method. The optimized enzyme reaction condition contained 1.5 μg of HMGR, 20 nM of NADPH with 50 min of reaction time. The method was validated by several intra- and inter-day assays. The production transitions of m/z 147.0/59.1 and m/z 154.0/59.1 were used to detect and quantify mevalonolactone (MVAL) and MVAL-D7, respectively. The accuracy and precision of the method were evaluated over the concentration range of 0.005–1.000 μg/mL for MVAL and 0.010–0.500 μg/mL for lovastatin acid in three validation batch runs. The lower limit of quantitation was found to be 0.005 μg/mL for MVAL and 0.010 μg/mL for lovastatin acid. Intra-day and inter-day precision ranged from 0.95% to 2.39% and 2.26% to 3.38% for MVAL, 1.46% to 3.89% and 0.57% to 5.10% for lovastatin acid, respectively. The results showed that the active ingredients in Xuezhikang capsules were 12.2 and 14.5 mg/g, respectively. This assay method could be successfully applied to the quality control study of Xuezhikang capsule for the first time.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.