Contractile force is transmitted to the skeleton through tendons and aponeuroses, and, although it is appreciated that the mechanocharacteristics of these tissues play an important role for movement performance with respect to energy storage, the association between tendon mechanical properties and the contractile muscle output during high-force movement tasks remains elusive. The purpose of the study was to investigate the relation between the mechanical properties of the connective tissue and muscle performance in maximal isometric and dynamic muscle actions. Sixteen trained men participated in the study. The mechanical properties of the vastus lateralis tendon-aponeurosis complex were assessed by ultrasonography. Maximal isometric knee extensor force and rate of torque development (RTD) were determined. Dynamic performance was assessed by maximal squat jumps and countermovement jumps on a force plate. From the vertical ground reaction force, maximal jump height, jump power, and force-/velocity-related determinants of jump performance were obtained. RTD was positively related to the stiffness of the tendinous structures (r = 0.55, P < 0.05), indicating that tendon mechanical properties may account for up to 30% of the variance in RTD. A correlation was observed between stiffness and maximal jump height in squat jumps and countermovement jumps (r = 0.64, P < 0.05 and r = 0.55, P < 0.05). Power, force, and velocity parameters obtained during the jumps were significantly correlated to tendon stiffness. These data indicate that muscle output in high-force isometric and dynamic muscle actions is positively related to the stiffness of the tendinous structures, possibly by means of a more effective force transmission from the contractile elements to the bone.
The purpose of this study was to examine patellar tendon (PT) size and mechanical properties in subjects with a side-to-side strength difference of > or =15% due to sport-induced loading. Seven elite fencers and badminton players were included. Cross-sectional area (CSA) of the PT obtained from MRI and ultrasonography-based measurement of tibial and patellar movement together with PT force during isometric contractions were used to estimate mechanical properties of the PT bilaterally. We found that distal tendon and PT, but not mid-tendon, CSA were greater on the lead extremity compared with the nonlead extremity (distal: 139 +/- 11 vs. 116 +/- 7 mm(2); mid-tendon: 85 +/- 5 vs. 77 +/- 3 mm(2); proximal: 106 +/- 7 vs. 83 +/- 4 mm(2); P < 0.05). Distal tendon CSA was greater than proximal and mid-tendon CSA on both the lead and nonlead extremity (P < 0.05). For a given common force, stress was lower on the lead extremity (52.9 +/- 4.8 MPa) compared with the nonlead extremity (66.0 +/- 8.0 MPa; P < 0.05). PT stiffness was also higher in the lead extremity (4,766 +/- 716 N/mm) compared with the nonlead extremity (3,494 +/- 446 N/mm) (P < 0.05), whereas the modulus did not differ (lead 2.27 +/- 0.27 GPa vs. nonlead 2.16 +/- 0.28 GPa) at a common force. These data show that a habitual loading is associated with a significant increase in PT size and mechanical properties.
The free Achilles tendon demonstrates greater strain compared with that of the distal (deep) aponeurosis during voluntary isometric contraction, which suggests that separate functional roles may exist during in vivo force transmission.
The purpose of this study was to test the hypothesis that remodeling of skeletal muscle extracellular matrix (ECM) is involved in protecting human muscle against injury. Biopsies were obtained from medial gastrocnemius muscles after a single bout of electrical stimulation (B) or a repeated bout (RB) 30 d later, or 30 d after a single stimulation bout (RBc). A muscle biopsy was collected from the control leg for comparison with the stimulated leg. Satellite cell content, tenascin C, and muscle regeneration were assessed by immunohistochemistry; real-time PCR was used to measure mRNA levels of collagens, laminins, heat-shock proteins (HSPs), inflammation, and related growth factors. The large responses of HSPs, CCL2, and tenascin C detected 48 h after a single bout were attenuated in the RB trial, indicative of protection against injury. Satellite cell content and 12 target genes, including IGF-1, were elevated 30 d after a single bout. Among those displaying the greatest difference vs. control muscle, ECM laminin-β1 and collagen types I and III were elevated ∼6- to 9-fold (P<0.001). The findings indicate that the sequenced events of load-induced early deadhesion and later strengthening of skeletal muscle ECM play a role in protecting human muscle against future injury.
. Differential displacement of the human soleus and medial gastrocnemius aponeuroses during isometric plantar flexor contractions in vivo. J Appl Physiol 97: 1908 -1914, 2004. First published June 25, 2004 doi:10.1152/ japplphysiol.00084.2004.-The human triceps surae muscle-tendon complex is a unique structure with three separate muscle compartments that merge via their aponeuroses into the Achilles tendon. The mechanical function and properties of these structures during muscular contraction are not well understood. The purpose of the study was to investigate the extent to which differential displacement occurs between the aponeuroses of the medial gastrocnemius (MG) and soleus (Sol) muscles during plantar flexion. Eight subjects (mean Ϯ SD; age 30 Ϯ 7 yr, body mass 76.8 Ϯ 5.5 kg, height 1.83 Ϯ 0.06 m) performed maximal isometric ramp contractions with the plantar flexor muscles. The experiment was performed in two positions: position 1, in which the knee joint was maximally extended, and position 2, in which the knee joint was maximally flexed (125°). Plantarflexion moment was assessed with a strain gauge load cell, and the corresponding displacement of the MG and Sol aponeuroses was measured by ultrasonography. Differential shear displacement of the aponeurosis was quantified by subtracting displacement of Sol from that of MG. Maximal plantar flexion moment was 36% greater in position 1 than in position 2 (132 Ϯ 20 vs. 97 Ϯ 11 N ⅐ m). In position 1, the displacement of the MG aponeurosis at maximal force exceeded that of the Sol (12.6 Ϯ 1.7 vs. 8.9 Ϯ 1.5 mm), whereas in position 2 displacement of the Sol was greater than displacement of the MG (9.6 Ϯ 1.0 vs. 7.9 Ϯ 1.2 mm). The amount and "direction" of shear between the aponeuroses differed significantly between the two positions across the entire range of contraction, indicating that the Achilles tendon may be exposed to intratendinous shear and stress gradients during human locomotion. triceps surae; Achilles tendon; ultrasound; connective tissue mechanical properties; tendon shear strain; intratendinous stress THE HUMAN TRICEPS SURAE muscle-tendon structure is intricate in constitution and function, with three separate muscle compartments that merge via their aponeuroses into a common tendon to ultimately insert on the calcaneus. The combined forces generated by the triceps surae muscles during locomotion are transmitted to the Achilles tendon and may reach 1,400 -2,600 N during walking and 3, 100 -5,330 N during running (13, 15, 34). It has been suggested that these large forces imposed on the tendon contribute to various loading-related pathologies such as tendinopathy (19), although the exact etiology remains largely intangible. Consequently, a more detailed understanding of the intrinsic contraction properties of the multipart triceps surae structure may contribute to the development of future treatment paradigms and/or prophylactic intervention models.Information on the mechanical properties and function of the aponeurosis and tendon have tradition...
The primary aim of our study was to validate the assessment of myonuclear and satellite cell number in biopsies from human skeletal muscle. We found that 25 type I and 25 type II fibers are sufficient to estimate the mean number of myonuclei per fiber. In contrast, the assessment of satellite cells improved when more fibers were included. Second, we report that small differences in counting satellite cells using CD56 and Pax7 antibodies can be attributed to the different staining profiles. Third, we provide support for the use of Ki67 in evaluating the proportion of active satellite cells. We observed very few (up to 1.3%) active satellite cells in healthy adult skeletal muscle at rest, but they increased significantly (up to 7-fold) following muscle activity. This study provides valuable tools to assess the behavior of satellite cells, both in pathological conditions and in response to physiological stimuli.
In the past 20 years, the use of ultrasound-based methods has become a standard approach to measure tendon mechanical properties in vivo. Yet the multitude of methodological approaches adopted by various research groups probably contribute to the large variability of reported values. The technique of obtaining and relating tendon deformation to tensile force in vivo has been applied differently, depending on practical constraints or scientific points of view. Divergence can be seen in 1) methodological considerations, such as the choice of anatomical features to scan and to track, force measurements, or signal synchronization; and 2) in physiological considerations related to the viscoelastic behavior or length measurements of tendons. Hence, the purpose of the present review is to assess and discuss the physiological and technical aspects connected to in vivo testing of tendon mechanical properties. In doing so, our aim is to provide the reader with a qualitative analysis of ultrasound-based techniques. Finally, a list of recommendations is proposed for a number of selected issues.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.