Lower body negative pressure (LBNP) may provide an alternative test of cardiovascular autonomic function for patients unable to perform the Valsalva maneuver (VM). LBNP at -40 mmHg for 30 s was compared to the VM at 40 mmHg for 15 s with heart rate and blood pressure measured continuously in three age groups: 10-25 years; 26-40 years; and 41-55 years. Heart rate and blood pressure responses were comparable, with moderately diminished changes in blood pressure and heart rate in the LBNP test. When heart response to LBNP was converted to a ratio similar to that calculated for the VM, a high degree of correlation was found (R(2) = 0.5711). The LBNP test shows promise as an alternative test of cardiovascular autonomic function based on studies in normal subjects. The less marked changes may relate to the more passive nature of the applied stress. Future work should improve the device's accessibility and establish values for patients with autonomic disorders.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.