The Open National Combustion Code (OpenNCC) is applied to the simulation of a realistic combustor configuration (Energy Efficient Engine (E 3)) in order to investigate the unsteady flow fields inside the combustor and around the first stage stator of a high pressure turbine (HPT). We consider one-twelfth (24 degrees) of the full annular E 3 combustor with three different geometries of the combustor exit: one without the vane, and two others with the vane set at different relative positions in relation to the fuel nozzle (clocking). Although it is common to take the exit flow profiles obtained by separately simulating the combustor and then feed it as the inflow profile when modeling the HPT, our studies show that the unsteady flow fields are influenced by the presence of the vane as well as clocking. More importantly, the characteristics (e.g., distribution and strength) of the high temperature spots (i.e., hot-streaks) appearing on the vane significantly alters. This indicates the importance of simultaneously modeling both the combustor and the HPT to understand the mechanics of the unsteady formulation of hot-streaks.
This paper presents a CFD model for simulating the self-pressurization of a large scale liquid hydrogen storage tank. In this model, the kinetics-based Schrage equation is used to account for the evaporative and condensing interfacial mass flows. Laminar and turbulent approaches to modeling natural convection in the tank and heat and mass transfer at the interface are compared. The flow, temperature, and interfacial mass fluxes predicted by these two approaches during tank self-pressurization are compared against each other. The ullage pressure and vapor temperature evolutions are also compared against experimental data obtained from the MHTB self-pressurization experiment. A CFD model for cooling cryogenic storage tanks by spraying cold liquid in the ullage is also presented. The EulerLagrange approach is utilized for tracking the spray droplets and for modeling interaction between the droplets and the continuous phase (ullage). The spray model is coupled with the VOF model by performing particle tracking in the ullage, removing particles from the ullage when they reach the interface, and then adding their contributions to the liquid. Dropletullage heat and mass transfer are modeled. The flow, temperature, and interfacial mass flux predicted by the model are presented. The ullage pressure is compared with experimental data obtained from the MHTB spray bar mixing experiment. The results of the models with only droplet/ullage heat transfer and with heat and mass transfer between the droplets and ullage are compared.
NomenclatureA = Area density Greek E = Energy = Cell value of volume fraction g = Gravity = Slope limiter h = Surface curvature = Face value of volume fraction k = Turbulence kinetic energy = Dynamic viscosity L = Latent heat = Density M = Molar mass of fluid = Stress tensor n = Normal vector = Specific turbulence dissipation rate p, P = Pressure q = Heat flux Subscripts Q = Heat power i = Interface or phase R = Gas constant il = Liquid side of the interface T = Temperature iv = Vapor side of the interface t = Time sat = Saturation conditions v = Velocity l = Liquid c p = Heat capacity at constant pressure v = Vapor m = Mass p = Particle Downloaded by PRINCETON UNIVERSITY on August 11, 2015 | http://arc.aiaa.org |
An unstructured and massively parallel Reynolds-Averaged Navier-Stokes (RANS) code is used to simulate 3-D, turbulent, non-reacting, and confined swirling flow field associated with a single-element and a nine-element Lean Direct Injection (LDI) combustor. In addition, the computed results are compared with the Large Eddy Simulation (LES) results and are also validated against the experimental data. The LDI combustors are a new generation of liquid fuel combustors developed to reduce aircraft NOx emission to 70% below the 1996 International Civil Aviation Organization (ICAO) standards and to maintain carbon monoxide and unburned hydrocarbons at their current low levels at low power conditions. The concern in the stratosphere is that NOx would react with the ozone and deplete the ozone layer. This paper investigates the non-reacting aerodynamics characteristics of the flow associated with these new combustors using a RANS computational method. For the single-element LDI combustor, the experimental model consists of a cylindrical air passage with air swirlers and a converging-diverging venturi section, extending to a confined 50.8-mm square flame tube. The air swirlers have helical, axial vanes with vane angles of 60 degree. The air is highly swirled as it passes through the 60 degree swirlers and enters the flame tube. The nine-element LDI combustor is comprised of 9 elements that are designed to fit within a 76 mm 76 mm flametube combustor. In the experimental work, the jet-A liquid fuel is supplied through a small diameter fuel injector tube and is atomized as it exits the tip and enters the flame tube. The swirling and mixing of the fuel and air induces recirculation zone that anchors the combustion process, which is maintained as long as a flammable mixture of fuel and air is supplied. It should be noted that in the numerical simulation reported in this paper, only the non-reacting flow is considered. The numerical model encompasses the whole experimental flow passage, including the flow development sections for the air swirlers, and the flame tube. A low Reynolds number K-e turbulence model is used to model turbulence. Several RANS calculations are performed to determine the effects of the grid resolution on the flow field. The grid is refined several times until no noticeable change in the computed flow field occurred; the final refined grid is used for the detailed computations. The results presented are for the final refined grid. The final grids are all hexahedron grids containing approximately 861,823 cells for the single-element and 1,567,296 cells for the nine-element configuration. Fine details of the complex flow structure such as helical-ring vortices, re-circulation zones and vortex cores are well captured by the simulation. Consistent with the non-reacting experimental results, the computation model predicts a major re-circulation zone in the central region, immediately downstream of the fuel nozzle, and a second, recirculation zone in the upstream corner of the combustion chamber. Further, the computed results predict the experimental data with reasonable accuracy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.