MTA materials have been shown to have a biocompatible nature and have excellent potential in endodontic use. MTA materials are a refined Portland cement material and the substitution of Portland cement for MTA products is presently discouraged. Existing human studies involving MTA materials are very promising, however, insufficient randomized, double-blind clinical studies of sufficient duration exist involving MTA for all of its clinical indications. Further clinical studies are needed in these areas.
Threaded lumbar interbody spinal fusion devices (TIBFD) made from titanium have been reported to be 90% effective for single-level lumbar interbody fusion, although radiographic determination of fusion has been intensely debated in the literature. Using blinded radiographic, biomechanic, histologic, and statistical measures, we evaluated a radiolucent polyetheretherketone (PEEK)-threaded interbody fusion device packed with autograft or rhBMP-2 on an absorbable collagen sponge in 13 sheep at 6 months. Radiographic fusion, increased spinal level biomechanical stiffness, and histologic fusion were demonstrated for the PEEK cages filled with autograft or rhBMP-2 on a collagen sponge. No device degradation or wear debris was observed. Only mild chronic inflammation consisting of a few macrophages was observed in peri-implant tissues. Based on these results, the polymeric biomaterial PEEK may be a useful biomaterial for interbody fusion cages due to the polymer's increased radiolucency and decreased stiffness.
The study presented here investigated hydroxyapatite biomaterials implanted in soft-tissue sites in adult sheep to determine whether these materials are osteoinductive and whether the rate of osteoinduction can be increased by manipulating the composition and porosity of the implants. For the study, 16.8-mm x 5-mm discs were prepared from mixtures of hydroxyapatite and beta-tricalcium phosphate. Five mixtures of hydroxyapatite-ceramic and hydroxyapatite-cement paste forms were studied: 100 percent hydroxyapatite-ceramic (Interpore), 60 percent hydroxyapatite-ceramic, 100 percent hydroxyapatite-cement paste, 60 percent hydroxyapatite-cement paste, and 20 percent hydroxyapatite-cement paste. Biomaterials were implanted in subcutaneous and intramuscular soft-tissue pockets in 10 adult sheep. Cranial bone grafts of equal dimension were implanted as controls. One year after implantation, the volume of all biomaterials and bone grafts was determined from a computed tomographic scan, and porosity and bone formation were determined using backscatter electron microscopy. Cranial bone and the 20 percent hydroxyapatite-cement paste implants demonstrated significant volume reduction in all sites after 1 year (p < 0.001). No significant difference in volume of the remaining four biomaterials was found. There was no significant change in pore size in the ceramic implants (range, 200 to 300 micro) and in the cement-paste implants containing 60 percent hydroxyapatite or more (range, 3 to 5 nm). Pore size in the cement-paste implants containing 20 percent hydroxyapatite increased significantly with resorption of the tricalcium-phosphate component, reaching a maximum of 200 to 300 micro in the periphery, where the greatest tricalcium-phosphate resorption had occurred. Both ceramic biomaterials demonstrated lamellar bone deposition within well-formed haversian systems through the entire depth of the implants, ranging from a mean of 6.6 percent to 11.7 percent. There was minimal bone formation in the cement-paste implants containing 60 percent hydroxyapatite or more. In contrast, cement-paste implants containing 20 percent hydroxyapatite demonstrated up to 10 percent bone replacement, which was greatest in the periphery of the implants where the greatest tricalcium-phosphate resorption had occurred. This study confirms the occurrence of true osteoinduction within hydroxyapatite-derived biomaterials, when examined using backscatter techniques. In this study, the rate of osteoinduction was greatest when a porous architecture was maintained, which was best achieved in ceramic rather than cement-paste forms of hydroxyapatite. Porosity and resultant bone formation in cement-paste implants can be improved by combining hydroxyapatite with a rapidly resorbing component, such as tricalcium phosphate.
No mechanical, radiographic, or histologic differences in the quality of intertransverse process fusion resulted from a 40-fold variation in dose of recombinant human bone morphogenetic protein-2.
Increasing the local rhBMP-2 concentration by overfilling the defect with rhBMP-2/ACS or hyperconcentrating the rhBMP-2 solution on the absorbable collagen sponge led to a concentration-dependent osteoclastic resorption of peri-implant bone. The osteoclastic effect was transient, and progressive healing took place over the 8-week survival period.
Introduction
Coarctation of the aorta (CoA) is associated with morbidity despite treatment. Although mechanisms remain elusive, abnormal hemodynamics and vascular biomechanics are implicated. We present a novel approach that facilitates quantification of coarctation-induced mechanical alterations and their impact on vascular structure and function, without genetic or confounding factors.
Methods
Rabbits underwent thoracic CoA at 10 weeks of age ( ~9 human years) to induce a 20 mmHg blood pressure (BP) gradient using permanent or dissolvable suture thereby replicating untreated and corrected CoA. Computational fluid dynamics (CFD) was performed using imaging and BP data at 32 weeks to quantify velocity, strain and wall shear stress (WSS) for comparison to vascular structure and function as revealed by histology and myograph results.
Results
Systolic and mean BP was elevated in CoA compared to corrected and control rabbits leading to vascular thickening, disorganization and endothelial dysfunction proximally and distally. Corrected rabbits had less severe medial thickening, endothelial dysfunction, and stiffening limited to the proximal region despite 12 weeks of normal BP (~4 human years) after the suture dissolved. WSS was elevated distally for CoA rabbits, but reduced for corrected rabbits.
Discussion
These findings are consistent with alterations in humans. We are now poised to investigate mechanical contributions to mechanisms of morbidity in CoA using these methods.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.