A wireless electrical stimulation implant for peripheral nerves, achieving >10× improvement over state of the art in the depth/volume figure of merit, is presented. The fully integrated implant measures just 2 mm × 3 mm × 6.5 mm (39 mm, 78 mg), and operates at a large depth of 10.5 cm in a tissue phantom. The implant is powered using ultrasound and includes a miniaturized piezoelectric receiver (piezo), an IC designed in 180 nm HV BCD process, an off-chip energy storage capacitor, and platinum stimulation electrodes. The package also includes an optional blue light-emitting diode for potential applications in optogenetic stimulation in the future. A system-level design strategy for complete operation of the implant during the charging transient of the storage capacitor, as well as a unique downlink command/data transfer protocol, is presented. The implant enables externally programmable current-controlled stimulation of peripheral nerves, with a wide range of stimulation parameters, both for electrical (22 to 5000 μA amplitude, ∼14 to 470 μs pulse-width, 0 to 60 Hz repetition rate) and optical (up to 23 mW/mm optical intensity) stimulation. Additionally, the implant achieves 15 V compliance voltage for chronic applications. Full integration of the implant components, end-to-end in vitro system characterizations, and results for the electrical stimulation of a sciatic nerve, demonstrate the feasibility and efficacy of the proposed stimulator for peripheral nerves.
Miniaturized ultrasonic receivers are designed for efficient powering of implantable medical devices with reconfigurable power loads. Design parameters that affect the efficiency of these receivers under highly variable load conditions, including piezoelectric material, geometry, and operation frequency, are investigated. Measurements were performed to characterize electrical impedance and acoustic-to-electrical efficiency of ultrasonic receivers for off-resonance operation. Finally, we propose, analyze, and demonstrate adaptive matching and frequency tuning techniques using two different reconfigurable matching networks for typical implant loads from 10 [Formula: see text] to 1 mW. Both simulations and measurements show a significant increase in total implant efficiency (up to 50 percentage points) over this load power range when operating off-resonance with the proposed matching networks.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.