We have measured the intensity profile and transmission of x rays focused by a series of either spherical or parabolic lenses fabricated using Mylar® (C5H4O2) or Kapton® (polyimide). The use of plastics can extend the range of operation of compound refractive lenses, improving transmission and aperture size and reducing focal length. The number of unit lenses range from 193 to 600 for each compound refractive lens. Two-dimensional focusing was obtained for photon energies 8–14 keV with imaging distances of less than 1 m. For example, full-width-half-maximum linewidths down to 16 μm at a distance of only 47 cm from the lens were achieved at 9 keV. The effective apertures of the refractive lenses were measured between 250 and 364 μm with peak transmissions between 10% and 33%.
We present x-ray images of grid meshes and biological material obtained using an unfiltered x-ray tube and a compound refractive lens composed of microbubbles embedded in epoxy inside a glass capillary. Images obtained using this apparatus are compared with those using a synchrotron source and the same lens. We find that the field of view is larger than that obtained using the synchrotron source, whereas the contrast and resolution are reduced. Geometrical distortion around the edges of the field of view is also reduced. The experiments demonstrate the usefulness of the apparatus in a modest laboratory setting.
Images obtained with a high-magnification simple neutron microscope using a compound refractive lens are presented in this letter. The short focal length of the stack of Al biconcave lenses facilitated the setup of a simple neutron microscope at the D22 small angle scattering beam line at the Institut Laue Langevin, Grenoble, France that achieved a 35× magnification and a 214 μm resolution. Higher-resolution images could be obtained using improved neutron lens systems that enhance beam delivery from neutron sources and produce high-quality images in combination with higher resolution two-dimensional neutron detectors.
A compound refractive lens (CRL), consisting of a series of N closely spaced lens elements each of which contributes a small fraction of the total focusing, can be used to focus x rays or neutrons. The thickness of a CRL can be comparable to its focal length, whereupon a thick-lens analysis must be performed. In contrast with the conventional optical lens, where the ray inside the lens follows a straight line, the ray inside the CRL is continually changing direction because of the multiple refracting surfaces. Thus the matrix representation for the thick CRL is quite different from that for the thick optical lens. Principal planes can be defined such that the thick-lens matrix can be converted to that of a thin lens. For a thick lens the focal length is greater than for a thin lens with the same lens curvature, but this lengthening effect is less for the CRL than for the conventional optical lens.
The Lawrence Berkeley National Laboratory and Adelphi Technology Inc. have developed a series of high-yield neutron generators using the D-D reaction with an axial geometry. They operate with a single ion beam and can have a small origin size useful for immediate moderation and a high concentration of thermal neutrons. The generator uses RF induction discharge to efficiently ionize the deuterium gas. This discharge method provides high plasma density for high output current, high atomic species from molecular gases, long life operation and versatility for various discharge chamber geometries. These generators are open systems that can be actively pumped for a continuous supply of deuterium gas further increasing the generator's expected lifetime. Since the system is open, many of the components, including the target, can be easily replaced. Pulsed and continuous operation has been demonstrated. In either mode of operation these generators have been used for Prompt Gamma Neutron Activation Analysis (PGNAA) and neutron activation analysis (NAA). Carleton University and Heliocentric Technologies are developing an Elemental Analyzer based on this neutron source.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers