An injection protocol based on 60 mL of iopamidol (370 mg I/mL) for prospectively ECG-gated wide-area detector single-heartbeat coronary CT angiography (CTA) has less coronary enhancement than a protocol based on 80 mL. However, using 60 mL, more than 96% of coronary segments had sufficient enhancement (i.e., > 300 HU), supporting the general use of 60-mL protocols for clinical wide-area detector coronary CTA.
We report initial surgical planning computed tomographic protocols for composite tissue allotransplantation of the face. This complex procedure replaces missing facial structures with anatomically identical tissues, restoring form and function. Achieved results are superior to those accomplished with conventional techniques. As a growing number of patients/recipients have undergone multiple reconstructions, vascular imaging plays an increasingly critical role in surgical planning and successful execution of the operation.
SUMMARY:Facial allotransplantation replaces missing facial structures with anatomically identical tissues, providing desired functional, esthetic, and psychosocial benefits far superior to those of conventional methods. On the basis of very encouraging initial results, it is likely that more procedures will be performed in the near future. Typical candidates have extremely complex vascular anatomy due to severe injury and/or multiple prior reconstructive attempts; thus, each procedure is uniquely determined by the defects and vascular anatomy of the candidate. We detail CT angiography vascular mapping, noting the clinical relevance of the imaging, the angiosome concept and noninvasive delineation of the key vessels, and current controversies related to the vascular anastomoses.
Double oblique 4-chamber reformation methods that use intermediate short-axis images to optimize RV size predict outcomes better in patients with acute PE than do single oblique methods using only LV landmarks; however, their accuracy is not superior to that from measurements based on axial images.
To retrospectively evaluate prognostic accuracy of subjective assessment of right ventricle (RV) enlargement on CT pulmonary angiography (CTPA) images in comparison with objective measures of RV enlargement in patients with acute pulmonary embolism (PE). For 200 consecutive patients with acute PE, two readers blinded to patient outcomes subjectively determined whether the maximum RV diameter was greater than that of the left ventricle (LV) using axial CTPA images. For the objective measurements, RV/LV diameter ratios were calculated using axial images and 4-chamber reformatted images. For all assessments, sensitivities and specificities for predicting PE-related death within 30-days and a composite outcome including PE-related death or the need for intensive therapies were compared. The agreement between two readers was 91.5% (kappa = 0.83) and all other assessments had pair-wise agreement over 75% (kappa = 0.53-0.72). There was no significant difference in sensitivity between the subjective and objective methods for predicting both outcomes. The specificity for subjective RV enlargement (55.4-67.7%) was significantly higher than objective measures (45.8-53.1%), except for the 4-chamber views where, for one reader, the specificity of the subjective evaluation was higher but did not reach statistical significance. Complex measurements of RV/LV diameter ratios may not be needed to maximize the prognostic value from CTPA. The radiologist who interprets the CTPA images should report RV enlargement when the RV diameter subjectively appears larger than the LV.
The purpose of this study was to estimate dose reduction after implementation of asymmetrical cone beam processing using exposure differences measured in a water phantom and a small cohort of clinical coronary CTA patients. Two separate 320 × 0.5 mm detector row scans of a water phantom used identical cardiac acquisition parameters before and after software modifications from symmetric to asymmetric cone beam acquisition and processing. Exposure was measured at the phantom surface with Optically Stimulated Luminescence (OSL) dosimeters at 12 equally spaced angular locations. Mean HU and standard deviation (SD) for both approaches were compared using ROI measurements obtained at the center plus four peripheral locations in the water phantom. To assess image quality, mean HU and standard deviation (SD) for both approaches were compared using ROI measurements obtained at five points within the water phantom. Retrospective evaluation of 64 patients (37 symmetric; 27 asymmetric acquisition) included clinical data, scanning parameters, quantitative plus qualitative image assessment, and estimated radiation dose. In the water phantom, the asymmetric cone beam processing reduces exposure by approximately 20% with no change in image quality. The clinical coronary CTA patient groups had comparable demographics. The estimated dose reduction after implementation of the asymmetric approach was roughly 24% with no significant difference between the symmetric and asymmetric approach with respect to objective measures of image quality or subjective assessment using a four point scale. When compared to a symmetric approach, the decreased exposure, subsequent lower patient radiation dose, and similar image quality from asymmetric cone beam processing supports its routine clinical use.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.