Highly miniaturized P450 screening assays designed to enable facile analysis of P450 drug interactions in a 1536-well plate format with the principal human cytochrome P450 enzymes (CYP3A4, 2D6, 2C9, 2C19, and 1A2) and Vivid ® fluorogenic substrates were developed. The detailed characterization of the assays included stability, homogeneity, and reproducibility of the recombinant P450 enzymes and the kinetic parameters of their reactions with Vivid ® fluorogenic substrates, with a focus on the specific characteristics of each component that enable screening in a low-volume 1536-well plate assay format. The screening assays were applied for the assessment of individual cytochrome P450 inhibition profiles with a panel of selected assay modifiers, including isozyme-specific substrates and inhibitors. IC 50 values obtained for the modifiers in 96-and 1536-well plate formats were similar and comparable with values obtained in assays with conventional substrates. An overall examination of the 1536-well assay statistics, such as signal-to-background ratio and Z′ factor, demonstrated that these assays are a robust, successful, and reliable tool to screen for cytochrome P450 metabolism and inhibition in an ultra-high-throughput screening format. (Journal of Biomolecular Screening 2005:56-66)
Kinase-mediated phosphorylation of proteins is critical to the regulation of many biological processes, including cell growth, apoptosis, and differentiation. Because of the central role that kinases play in processes that can lead to disease states, the targeting of kinases with small-molecule inhibitors is a validated strategy for therapeutic intervention. Classic methods for assaying kinases include nonhomogenous enzyme-linked immunosorbent assays or scintillation-based formats using [gamma-(32)P]ATP. However, homogenous fluorescence-based assays have gained in popularity in recent years due to decreased costs in reagent usage through miniaturization, increased throughput, and avoidance of regulatory costs associated with the use of radiation. Whereas the readout signal from a nonhomogenous or radioactive assay is largely impervious to interferences from matrix components (such as library compounds), all homogenous fluorescent assay formats are subject to such interferences. Interference from intrinsically fluorescent compounds or from scattered light due to precipitated compounds can interfere with assays that depend on a fluorescence intensity (or fluorescence quenching), fluorescence resonance energy transfer, or fluorescence polarization-based readout. Because these interfering factors show a greater effect at lower wavelengths, one strategy to overcome such interferences is to develop fluorescent assays using longer wavelength (red-shifted) fluorescent probes. In this article, we describe the PanVera PolarScreen far-red fluorescence polarization assay format, which mitigates assay interference from autofluorescent compounds or scattered light through the use of a far-red tracer. The tracer shows substantially less interference from light scatter or autofluorescent library compounds than do fluorescein-based tracers, and gives rise to a larger assay window than the popular far-red fluorophore Cy5.
A problem inherent to the use of cellular assays for drug discovery is their sensitivity to cytotoxic compounds, which can result in false hits from certain compound screens. To alleviate the need to follow-up hits from a reporter assay with a separate cytotoxicity assay, the authors have developed a multiplexed assay that combines the readout of a β-lactamase reporter with that of a homogeneous cytotoxicity indicator. Important aspects to the development of the multiplexed format are addressed, including results that demonstrate that the IC 50 values of 40 select compounds in a β-lactamase reporter assay for nuclear factor κ B and SIE pathway antagonists are not affected by the addition of the cytotoxicity indicator. To demonstrate the improvement in hit confirmation, the multiplexed assay was used to perform a small-library screen (7728 compounds) for serotonin 5HT1A receptor antagonists. Hits identified from analysis of the β-lactamase reporter data alone were compared to those hits determined when the reporter and cytotoxicity data generated from the multiplexed assay were combined. Confirmation rates were determined from compound follow-up using dose-response analysis of the potential antagonist hits identified by the initial screen. In this representative screen, the multiplexed assay approach yielded a 19% reduction in the number of compounds flagged for followup, with a 37% decrease in the number of false hits, demonstrating that multiplexing a β-lactamase reporter assay with a cytotoxicity readout is a highly effective strategy for reducing false hit rates in cell-based compound screening assays. (Journal of Biomolecular Screening 2007:635-644)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.