Innate immune cells of the respiratory tract are the first line of defense against pathogenic and environmental insults. Failure of these cells to perform their immune functions leaves the host susceptible to infection and may contribute to impaired resolution of inflammation. While combustible tobacco cigarettes have been shown to suppress respiratory immune cell function, the effects of flavored electronic cigarette liquids (e-liquids) and individual flavoring agents on respiratory immune cell responses are unknown. We investigated the effects of seven flavored nicotine-free e-liquids on primary human alveolar macrophages, neutrophils, and natural killer (NK) cells. Cells were challenged with a range of e-liquid dilutions and assayed for their functional responses to pathogenic stimuli. End points included phagocytic capacity (neutrophils and macrophages), neutrophil extracellular trap formation, proinflammatory cytokine production, and cell-mediated cytotoxic response (NK cells). E-liquids were then analyzed via mass spectrometry to identify individual flavoring components. Three cinnamaldehyde-containing e-liquids exhibited dose-dependent broadly immunosuppressive effects. Quantitative mass spectrometry was used to determine concentrations of cinnamaldehyde in each of the three e-liquids, and cells were subsequently challenged with a range of cinnamaldehyde concentrations. Cinnamaldehyde alone recapitulated the impaired function observed with e-liquid exposures, and cinnamaldehyde-induced suppression of macrophage phagocytosis was reversed by addition of the small-molecule reducing agent 1,4-dithiothreitol. We conclude that cinnamaldehyde has the potential to impair respiratory immune cell function, illustrating an immediate need for further toxicological evaluation of chemical flavoring agents to inform regulation governing their use in e-liquid formulations.
The e-liquids used in electronic cigarettes (E-cigs) consist of propylene glycol (PG), vegetable glycerin (VG), nicotine, and chemical additives for flavoring. There are currently over 7,700 e-liquid flavors available, and while some have been tested for toxicity in the laboratory, most have not. Here, we developed a 3-phase, 384-well, plate-based, high-throughput screening (HTS) assay to rapidly triage and validate the toxicity of multiple e-liquids. Our data demonstrated that the PG/VG vehicle adversely affected cell viability and that a large number of e-liquids were more toxic than PG/VG. We also performed gas chromatography–mass spectrometry (GC-MS) analysis on all tested e-liquids. Subsequent nonmetric multidimensional scaling (NMDS) analysis revealed that e-liquids are an extremely heterogeneous group. Furthermore, these data indicated that (i) the more chemicals contained in an e-liquid, the more toxic it was likely to be and (ii) the presence of vanillin was associated with higher toxicity values. Further analysis of common constituents by electron ionization revealed that the concentration of cinnamaldehyde and vanillin, but not triacetin, correlated with toxicity. We have also developed a publicly available searchable website (www.eliquidinfo.org). Given the large numbers of available e-liquids, this website will serve as a resource to facilitate dissemination of this information. Our data suggest that an HTS approach to evaluate the toxicity of multiple e-liquids is feasible. Such an approach may serve as a roadmap to enable bodies such as the Food and Drug Administration (FDA) to better regulate e-liquid composition.
T-cell responses to minor histocompatibility antigens (mHAs) mediate both antitumor immunity (graft-versus-leukemia [GVL]) and graft-versus-host disease (GVHD) in allogeneic stem cell transplant. Identifying mHAs with high allele frequency, tight binding affinity to common HLA molecules, and narrow tissue restriction could enhance immunotherapy against leukemia. Genotyping and HLA allele data from 101 HLA-matched donor-recipient pairs (DRPs) were computationally analyzed to predict both class I and class II mHAs likely to induce either GVL or GVHD. Roughly twice as many mHAs were predicted in HLA-matched unrelated donor (MUD) stem cell transplantation (SCT) compared with HLA-matched related transplants, an expected result given greater genetic disparity in MUD SCT. Computational analysis predicted 14 of 18 previously identified mHAs, with 2 minor antigen mismatches not being contained in the patient cohort, 1 missed mHA resulting from a noncanonical translation of the peptide antigen, and 1 case of poor binding prediction. A predicted peptide epitope derived from GRK4, a protein expressed in acute myeloid leukemia and testis, was confirmed by targeted differential ion mobility spectrometry-tandem mass spectrometry. T cells specific to UNC-GRK4-V were identified by tetramer analysis both in DRPs where a minor antigen mismatch was predicted and in DRPs where the donor contained the allele encoding UNC-GRK4-V, suggesting that this antigen could be both an mHA and a cancer-testis antigen. Computational analysis of genomic and transcriptomic data can reliably predict leukemia-associated mHA and can be used to guide targeted mHA discovery.
E-cigarettes are noncombustible, electronic nicotine-delivery devices that aerosolize an e-liquid, i.e., nicotine, in a propylene glycol-vegetable glycerin vehicle that also contains flavors. While the effects of nicotine are relatively well understood, more information regarding the potential biological effects of the other e-liquid constituents is needed. This is a serious concern, because e-liquids are available in >7,000 distinct flavors. We previously demonstrated that many e-liquids affect cell growth/viability through an unknown mechanism. Since Ca2+ is a ubiquitous second messenger that regulates cell growth, we characterized the effects of e-liquids on cellular Ca2+ homeostasis. To better understand the extent of this effect, we screened e-liquids for their ability to alter cytosolic Ca2+ levels and found that 42 of 100 flavored e-liquids elicited a cellular Ca2+ response. Banana Pudding (BP) e-liquid, a representative e-liquid from this group, caused phospholipase C activation, endoplasmic reticulum (ER) Ca2+ release, store-operated Ca2+ entry (SOCE), and protein kinase C (PKCα) phosphorylation. However, longer exposures to BP e-liquid depleted ER Ca2+ stores and inhibited SOCE, suggesting that this e-liquid may alter Ca2+ homeostasis by short- and long-term mechanisms. Since dysregulation of Ca2+ signaling can cause chronic inflammation, ER stress, and abnormal cell growth, flavored e-cigarette products that can elicit cell Ca2+ responses should be further screened for potential toxicity.
Current lipidomics workflows are centered around acquisition of large data sets followed by lengthy data processing. A dual nESI-DIMS-MS platform was developed to perform real-time relative quantification between samples, providing data required for biomarker discovery and validation more quickly than traditional ESI-MS approaches. Nanosprayer activity and DIMS compensation field settings were controlled by a LabVIEW program synced to the accumulation portion of the ion trap scan function, allowing for full integration of the platform with a commercial mass spectrometer. By comparing samples with short electrospray pulses rather than constant electrospray, the DIMS and MS performance is normalized within an experiment, as signals are compared between individual mass spectra (ms time scale) rather than individual experiments (min-hr time scale). The platform was validated with lipid standards and extracts from nitrogen-deprived microalgae. Dual nESI-DIMS requires minimal system modification and is compatible with all traditional ion activation techniques and mass analyzers, making it a versatile improvement to shotgun lipidomics workflows.
The rapid release of new tobacco products requires high-throughput quantitative methods to support tobacco research. Sample preparation for LC-MS and GC-MS is time consuming and limits throughput. Paper spray tandem mass spectrometry (PS-MS/MS) is proposed and validated as a simple and rapid method for quantification of nicotine and cotinine in complex matrices to support tobacco-related research. Air liquid interface (ALI) human tracheobronchial epithelial cell (HTBEC) cultures were exposed to tobacco smoke using a Vitrocell VC-10 smoking machine. Apical culture washes (phosphate buffered saline, PBS) and basolateral media were analyzed with the PS-MS/MS method. GC-MS/MS was used as a comparative quantitative technique. The PS-MS/MS approach allowed for direct spotting of samples on the paper substrate, whereas the GC-MS/MS method required additional sample preparation in the form of solvent-solvent extraction. Limits of quantitation (LOQs) were higher with the PS-MS/MS approach than GC-MS/MS, but still below the relevant concentrations found in HTBEC smoke exposure experiments as well as most clinical applications. PS-MS/MS is readily achieved on mass spectrometers that include atmospheric pressure inlets, and allows for convenient quantification from complex matrices that would otherwise require additional sample preparation and chromatographic separation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.