Objective To assess the contrast-enhanced CT and ultrasonography (US) findings of intracholecystic papillary neoplasm (ICPN) and determine the imaging features predicting ICPN associated with invasive carcinoma (ICPN-IC). Materials and Methods In this retrospective study, we enrolled 119 consecutive patients, including 60 male and 59 female, with a mean age ± standard deviation of 63.3 ± 12.1 years, who had pathologically confirmed ICPN (low-grade dysplasia [DP] = 34, high-grade DP = 35, IC = 50) and underwent preoperative CT or US. Two radiologists independently assessed the CT and US findings, focusing on wall and polypoid lesion characteristics. The likelihood of ICPN-IC was graded on a 5-point scale. Univariable and multivariable logistic regression analyses were performed to identify significant predictors of ICPN-IC separately for wall and polypoid lesion findings. The performances of CT and US in distinguishing ICPN-IC from ICPN with DP (ICPN-DP) was evaluated using the area under the receiver operating characteristic curve (AUC). Results For wall characteristics, the maximum wall thickness (adjusted odds ratio [aOR] = 1.4; 95% confidence interval [CI]: 1.1–1.9) and mucosal discontinuity (aOR = 5.6; 95% CI: 1.3–23.4) on CT were independently associated with ICPN-IC. Among 119 ICPNs, 110 (92.4%) showed polypoid lesions. Regarding polypoid lesion findings, multiplicity (aOR = 4.0; 95% CI: 1.6–10.4), lesion base wall thickening (aOR = 6.0; 95% CI: 2.3–15.8) on CT, and polyp size (aOR = 1.1; 95% CI: 1.0–1.2) on US were independently associated with ICPN-IC. CT showed a higher diagnostic performance than US in predicting ICPN-IC (AUC = 0.793 vs. 0.676; p = 0.002). Conclusion ICPN showed polypoid lesions and/or wall thickening on CT or US. A thick wall, multiplicity, presence of wall thickening in the polypoid lesion base, and large polyp size are imaging findings independently associated with invasive cancer and may be useful for differentiating ICPN-IC from ICPN-DP.
Objective To compare Octopus multipurpose (MP) electrodes, which are capable of saline instillation and direct tissue temperature measurement, and conventional electrodes for radiofrequency ablation (RFA) in porcine livers in vivo . Materials and Methods Sixteen pigs were used in this study. In the first experiment, RFA was performed in the liver for 6 minutes using Octopus MP electrodes (n = 15 ablation zones) and conventional electrodes (n = 12 ablation zones) to investigate the effect of saline instillation. The ablation energy, electrical impedance, and ablation volume of the two electrodes were compared. In the second experiment, RFA was performed near the gallbladder (GB) and colon using Octopus MP electrodes (n = 12 ablation zones for each) with direct tissue temperature monitoring and conventional electrodes (n = 11 ablation zones for each). RFA was discontinued when the temperature increased to > 60℃ in the Octopus MP electrode group, whereas RFA was performed for a total of 6 minutes in the conventional electrode group. Thermal injury was assessed and compared between the two groups by pathological examination. Results In the first experiment, the ablation volume and total energy delivered in the Octopus MP electrode group were significantly larger than those in the conventional electrode group (15.7 ± 4.26 cm 3 vs. 12.5 ± 2.14 cm 3 , p = 0.027; 5.48 ± 0.49 Kcal vs. 5.04 ± 0.49 Kcal, p = 0.029). In the second experiment, thermal injury to the GB and colon was less frequently noted in the Octopus MP electrode group than that in the conventional electrode group (16.7% [2/12] vs. 90.9% [10/11] for GB and 8.3% [1/12] vs. 90.9% [10/11] for colon, p < 0.001 for all). The total energy delivered around the GB (2.65 ± 1.07 Kcal vs. 5.04 ± 0.66 Kcal) and colon (2.58 ± 0.57 Kcal vs. 5.17 ± 0.90 Kcal) were significantly lower in the Octopus MP electrode group than that in the conventional electrode group ( p < 0.001 for all). Conclusion RFA using the Octopus MP electrodes induced a larger ablation volume and resulted in less thermal injury to the adjacent organs compared with conventional electrodes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.