Aim
To assess the effect of immersion in distilled water or phosphate‐buffered saline (PBS) on the solubility, volumetric change and presence of voids of calcium silicate‐based root canal sealers (TotalFill BC, Sealer Plus BC and Bio‐C), in comparison with the gold standard epoxy resin‐based sealer (AH Plus).
Methodology
All properties were evaluated after immersion in distilled water or PBS. Solubility was determined by the percentage of mass loss, whereas volumetric change and presence of voids were evaluated by micro‐computed tomography, after 7 days of immersion. The volumetric change and percentage of voids between the baseline (after setting) and the experimental period were calculated. Statistical analysis was performed using one‐way anova and Tukey's or Student's t‐tests (α = 0.05).
Results
The calcium silicate‐based sealers had significantly greater solubility and volumetric loss than AH Plus, after immersion in distilled water or PBS (P < 0.05). Bio‐C had the greatest solubility (P < 0.05), followed by TotalFill BC and Sealer Plus BC, which were similar (P > 0.05). Regarding the volumetric change, AH Plus had a volume increase, with similar values in distilled water and PBS (P > 0.05). TotalFill BC, Sealer Plus BC and Bio‐C had a similar volumetric change (P > 0.05). The calcium silicate‐based materials had the greatest solubility and volume loss after immersion in distilled water (P < 0.05). There was no difference in the percentage of voids amongst the sealers, before and after immersion in distilled water or PBS (P > 0.05).
Conclusions
TotalFill BC, Sealer Plus BC and Bio‐C had significantly greater solubility and volumetric loss than AH Plus. Although storage in PBS significantly reduced the solubility and volumetric change of calcium silicate‐based sealers, their solubility remained above that recommend by ISO 6876. All the sealers evaluated had low and similar voids, even after immersion in distilled water or PBS.
ProDesign R presented the highest cyclic fatigue resistance and angular rotation to failure compared with Reciproc and Unicone. However, Reciproc showed higher torsional strength to failure.
In endodontic practice, thermally treated reciprocating instruments have been used for the root canal preparation of curved and constricted canals; therefore, these instruments should present high flexibility and suitable torsional strength to minimize the risk of instrument fracture.
Micro-CT evaluation of apical enlargement of molar root canals using rotary or reciprocating heattreated NiTi instruments Objective: The aim of this study was to evaluate the root canal preparation and apical enlargement of molar root canals with rotary or reciprocating heat-treated nickel-titanium (NiTi) instruments, by using micro-computed tomography (micro-CT). Methodology: Mesial root canals (n=48) of mandibular molars, with a curvature between 20° and 40°, were prepared with ProDesign Logic (PDL) 25.01 and 25.06 in rotary motion, or ProDesign R (PDR) 25.06 in reciprocating motion (PDR). Apical enlargement was performed with PDL35.01 and PDL35.05 or PDR35.05. Scanning with 9 µm resolution was performed before and after preparation, and, after apical enlargement, by using micro-CT. The percentage of volume increase, debris and untouched root canal surface, transportation, centralization and preparation time were analyzed. ANOVA and Tukey or Kruskall-Wallis and Dunn statistical tests were conducted (α=.05). Results: PDL promoted a higher apical percentage of volume increase, and lower percentage of debris and untouched root canal surface than PDR 25.06 preparation in entire canal and in all thirds (P<.05). Apical enlargement with PDL 35.05 and PDR 35.05 produced a higher percentage of volume increase in the apical region in relation to the initial preparation (P<.05). PDR 35.05 and PDL 35.05 showed similar results in relation to percentage of debris and untouched root canal surface in entire canal and in all thirds (P>.05). Centralization and transportation showed no difference (P>.05). PDR required less time to perform preparation and apical enlargement (P<.05). Conclusions: The apical enlargement 35.05 with CM heat-treatment instruments using reciprocating and rotary motion reduced the percentage of debris and untouched root canal surface, without causing deviations or procedural errors. The protocol of greater apical enlargement favors the cleaning of the root canals in both kinematics. Preparation by the reciprocating system was faster than by the rotary system.
The aim of this study was to evaluate the filling ability of a new premixed ready‐to‐use calcium silicate‐based sealer, in comparison with an epoxy resin‐based sealer by the single‐cone technique in flattened root canals. Thirty‐two flattened root canals of maxillary second premolars with buccal‐lingual diameter 4 or more times larger than the mesio‐distal diameter at 9 mm from the radiographic apex were selected. Root canals were prepared using Hyflex EDM 25/0.08 and additional preparation with ultrasonic tip Flatsonic and ProDesign Logic 25/0.03. After preparation, the root canals were filled with two root canal sealers (n = 16): Bio‐C Sealer or AH Plus using the single‐cone technique. Scanning was performed before and after root canal obturation using a Skycan 1176 micro‐computed tomography (micro‐CT) with an isotropic voxel size of 8.74 μm. The percentage of voids was analyzed in the cervical/middle thirds and in the apical third. Data were submitted to the Mann–Whitney test at a significance level of 5%. There was no statistical difference between Bio‐C Sealer and AH Plus (p > .05). The percentage of voids in the cervical/middle thirds was 8.94% (1.33–39.95) for Bio‐C Sealer and 9.30% (1.19–18.00) for AH Plus (p > .05). In the apical third, this percentage was 11.84% (4.85–27.00) for Bio‐C Sealer and 9.21% (1.34–28.78) for AH Plus (p > .05). By using the single‐cone technique, neither Bio‐C Sealer nor AH Plus provided a voids‐free root canal filling. Both sealers had similar filling ability in flattened root canals.
The aim of this study was to evaluate the filling ability of a new ready-to-use calcium silicate-based sealer using thermoplastic or single-cone technique in flattened root canals. Twenty-four flattened distal canals of mandibular molars with a buccolingual diameter 4 or more times larger than the mesiodistal diameter were selected. The root canals were prepared and filled (n = 12), according to the following techniques: thermoplastic or single-cone technique using Bio-C Sealer. The teeth were scanned using Skycan 1176 micro-computed tomography (micro-CT)-voxel size 8.74 µm, before and after filling the root canal. The percentage of voids in the filled root canals was evaluated, and the data were statistically analyzed using the unpaired t-test (α = 0.05). The root canals filled using the thermoplastic technique created a smaller percentage of voids in the cervical/middle thirds than those filled using the single-cone technique (p < 0.05). There was no difference in the percentage of voids using either technique in the apical third (p > 0.05). The flattened root canals in the cervical/middle thirds were better filled using the ready-to-use calcium silicate-based sealer associated to the thermoplastic technique, compared with the single-cone technique. In the apical third, the techniques showed similar filling ability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.