This study addresses the challenges a dissolving-grade pulp mill in Canada faced in 2014 in meeting its total reduced sulfur (TRS) gas emission limit. These emissions from the recovery boiler exit are controlled by passing the boiler exit gas through a TRS scrubber system. The mill employs a cyclonic direct contact evaporator to
concentrate black liquor to firing solids content. The off-gases from the direct contact evaporator flow to the effluent gas control system that consists of a venturi scrubber, a packed bed scrubber, and a heat recovery unit. Emissions of TRS greater than the regulated limit of 15 ppm were observed for a 4-month period in 2014. The level of emissions measured during this period was significantly higher than about 12 ppm, the expected average value based on historic experience. The problem persisted from mid-June 2014 until the annual mill shutdown in October 2014. The main TRS components detected and the performance of the Teller scrubber in capturing them are examined.
Other potential causes for these emissions are identified, including mechanical problems such as broken packing in the TRS packed bed scrubber, broken baffle plates in the scrubber, and cyclone evaporator leaks causing air ingress. Repairs were carried out during the mill shutdown, which eliminated the TRS emissions problem.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.