Objective: To evaluate the benefits of bilateral electrical stimulation for hearing-impaired adult subjects using the Nucleus 24 cochlear implant in a multicenter study, and to compare and quantify performance on speech perception measures in quiet and in noise and localization ability for unilateral and bilateral cochlear implant use. Design: Repeated single subject measures were carried out for each subject, with each subject serving as their own control. Assessment of unilateral and bilateral listening conditions for performance on tests of speech comprehension and sound localization were performed. Speech comprehension measures were performed in quiet at 0 degree azimuth and in the presence of background noise simultaneously presented from the same speaker and spatially separated by 90 degrees, at S+45°N45°and at S−45°N+45°. Test materials included Freiburger monosyllabic words, Oldenburger sentences, and the Hochmair-Schulz-Moser sentences. Tests of localization were performed in the horizontal plane with 12 speaker locations 30 degrees apart using a shortened sentence stimulus from the Hochmair-Schulz-Moser sentences at two possible presentation levels of 55 and 70 dB sound pressure level for assessment of directionality. The binaural advantage provided by bilateral stimulation was calculated with respect to each ear separately, classified as either the better or poorer performing ear for each speech material in quiet and in noise test conditions. For localization of sound, the binaural advantage was compared with left and right ears separately. Paired comparisons for performance data in all conditions were carried out by considering measurements for each subject in different conditions as paired observations and applying the Student's t test to determine the statistical difference between the data sets. Setting: Tertiary referral centers with a cochlear implant program. Patients: Thirty-seven profoundly hearing-impaired adults were enrolled in the study, 22 simultaneously and 15 sequentially bilaterally implanted. All patients received the Nucleus 24 cochlear implant and used the Nucleus SPrint or ESPrit 3G speech processor, with the vast majority using the ACE speech coding strategy. Results: For spatially separated speech in noise conditions, an interaural performance advantage for the ear closest to the speech source (i.e., with a superior signal to noise ratio) compared with that for the ear closest to the noise source (i.e., with an inferior signal to noise ratio) is consistently demonstrated regardless of whether it is the better or poorer performing ear closest to the speech signal. This is referred to as a significant binaural head-shadow benefit, resulting in a mean improvement between −10 dB and −11.4 dB in the critical signal to noise ratio required for 50% speech comprehension for the Oldenburger sentences and a mean improvement in the maximum score of 42% to 55% for the ear closest to the speech signal over the ear farthest away for the Hochmair-Schulz-Moser sentences. Bilateral stimulation i...
One hundred and forty-seven adult recipients of the Nucleus 24 cochlear implant system, from 13 different European countries, were tested using neural response telemetry to measure the electrically evoked compound action potential (ECAP), according to a standardised postoperative measurement procedure. Recordings were obtained in 96% of these subjects with this standardised procedure. The group results are presented in terms of peak amplitude and latency, slope of the amplitude growth function and ECAP threshold. The effects of aetiological factors and the duration of deafness on the ECAP were also studied. While large intersubject variability and intrasubject variability (across electrodes) were found, results fell within a consistent pattern and a normative range of peak amplitudes and latencies was established. The aetiological factors had little effect on the ECAP characteristics. However, age affected ECAP amplitude and slope of the amplitude growth function significantly; i.e., the amplitude is higher in the lowest age category (15-30 years). Principal component analysis of the ECAP thresholds shows that the thresholds across 5 electrodes can be described by two factors accounting for 92% of the total variance. The two factors represent the overall level of the threshold profiles ('shift') and their slopes across the electrode array ('tilt'). Correlation between these two factors and the same factors describing the T-and C-levels appeared to be moderate, in the range of 0.5-0.6. AbstractOne hundred and forty-seven adult recipients of the Nucleus ® 24 cochlear implant system, from 13 different European countries, were tested using neural response telemetry to measure the electrically evoked compound action potential (ECAP), according to a standardised postoperative measurement procedure. Recordings were obtained in 96% of these subjects with this standardised procedure. The group results are presented in terms of peak amplitude and latency, slope of the amplitude growth function and ECAP threshold. The effects of aetiological factors and the duration of deafness on the ECAP were also studied. While large intersubject variability and intrasubject variability (across electrodes) were found, results fell within a consistent pattern and a normative range of peak amplitudes and latencies was established. The aetiological factors had little effect on the ECAP characteristics. However, age affected ECAP amplitude and slope of the amplitude growth function significantly; i.e., the amplitude is higher in the lowest age category (15-30 years). Principal component analysis of the ECAP thresholds shows that the thresholds across 5 electrodes can be described by two factors accounting for 92% of the total variance. The two factors represent the overall level of the threshold profiles ('shift') and their slopes across the electrode array ('tilt'). Correlation between these two factors and the same factors describing the T-and C-levels appeared to be moderate, in the range of 0.5-0.6.
Intracochlear recordings in cochlear implant recipients provide access to the electrically evoked compound action potential (ECAP). ECAP thresholds are potential predictors of speech processor map’s threshold and comfortable loudness levels. The auditory nerve’s refractory properties can influence these levels due to high-rate stimulation with interpulse intervals within the relative refractory period. Recovery functions were investigated at 84 stimulation sites in 14 Nucleus CI24 recipients using neural response telemetry and a modified forward masking technique. This technique introduces a reference masker-probe interval (MPI). In our study, an appropriate value between 300 and 375 µs was determined for this reference MPI, and the use of a reference MPI of 300 µs is suggested for recovery and amplitude growth functions. A median absolute refractory period of about 390 µs and a median time constant of about 425 µs were obtained by fitting an exponential model to the data. Hence, the auditory nerve is usually in relative refractory state when standard neural response telemetry forward masking is selected because of its default MPI of 500 µs. This can bias the measurement of ECAP thresholds. Additionally, the shape of standard forward masking recovery functions was explained by the influence of latency shift of the neural response.
AutoNRT provides comparable accuracy to an average clinician but with the added benefit of significant time savings over manual recordings. This makes it a valuable tool for clinical measurement of ECAP threshold in cochlear implant recipients.
As the CI users differed significantly in their SRT and their s50, a unified discrimination function for CI users must not be used. Further tailoring of the procedure may be required, especially for poorer CI performers.
Individual speech intelligibility was measured in quiet and noise for cochlear Implant recipients upgrading from the Freedom to the CP900 series sound processor. The postlingually deafened participants (n = 23) used either Nucleus CI24RE or CI512 cochlear implant, and currently wore a Freedom sound processor. A significant group mean improvement in speech intelligibility was found in quiet (Freiburg monosyllabic words at 50 dBSPL) and in noise (adaptive Oldenburger sentences in noise) for the two CP900 series SmartSound programs compared to the Freedom program. Further analysis was carried out on individual’s speech intelligibility outcomes in quiet and in noise. Results showed a significant improvement or decrement for some recipients when upgrading to the new programs. To further increase speech intelligibility outcomes when upgrading, an enhanced upgrade procedure is proposed that includes additional testing with different signal-processing schemes. Implications of this research are that future automated scene analysis and switching technologies could provide additional performance improvements by introducing individualized scene-dependent settings.
The outcome and success of rehabilitation of patients with cochlear implants (CIs) is determined to a large extent by the preoperative diagnostics and individual fitting of the speech processor and is assessed by the auditory performance of the CI recipient. Due to the wide spectrum of auditory abilities of recipients and to the large variability with respect to their age and experience, the postoperative audiologic assessment is based on a large battery of subjective tests and objective measures. The results of these functional tests are used for documenting the level of rehabilitation, and they determine the actions taken for fine-tuning the fitting of the speech processor.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.