48 Background. Nucleic acid amplification tests (NAATs) are the primary means of 49 identifying acute infections caused by severe acute respiratory syndrome coronavirus 2 50 (SARS-CoV-2). Accurate and fast test results may permit more efficient use of protective and 51 isolation resources and allow for rapid therapeutic interventions. 52 Methods. We evaluated the analytical and clinical performance characteristics of the Xpert ® 53 Xpress SARS-CoV-2 (Xpert) test, a rapid, automated molecular test for SARS-CoV-2. 54 Analytical sensitivity and specificity/interference were assessed with infectious SARS-CoV-2, 55 other infectious coronavirus species including SARS-CoV, and 85 nasopharyngeal swab 56 specimens positive for other respiratory viruses including endemic human coronaviruses 57 (hCoVs). Clinical performance was assessed using 483 remnant upper and lower respiratory 58 specimens previously analyzed by standard of care (SOC) NAATs. 59 Results. The limit of detection of the Xpert test was 0.01 plaque forming units (PFU)/mL. 60 Other hCoVs, including Middle East Respiratory Syndrome coronavirus, were not detected by 61 the Xpert test. SARS-CoV, a closely related species in the Sarbecovirus subgenus, was 62 detected by a broad-range target (E) but was distinguished from SARS-CoV-2 (SARS-CoV-2-63 specific N2 target). Compared to SOC NAATs, the positive agreement of the Xpert test was 64 219/220 (99.5%) and the negative agreement was 250/261 (95.8%). A third tie-breaker 65 NAAT resolved all but three of the discordant results in favor the Xpert test. 66 Conclusions. The Xpert test provided sensitive and accurate detection of SARS-CoV-2 in a 67 variety of upper and lower respiratory tract specimens. The high sensitivity and fast time to 68 results of approximately 45 minutes may impact patient management. 69 70 Laboratory diagnosis of infections caused by severe acute respiratory syndrome coronavirus 2 72 (SARS-CoV-2) is usually accomplished by performing nucleic acid amplification tests 73 (NAATs) on respiratory tract specimens. An antibody response is often not detected in the 74 first week to ten days of symptoms and antibody testing is therefore generally unhelpful for 75 acute diagnosis(1-3), with virus isolation in culture presenting significant biosafety risks. 76 Upper respiratory tract (URT) specimens such as nasopharyngeal swabs (NPS) and 77 oropharyngeal swabs (OPS) generally have high SARS-CoV-2 viral loads upon symptom 78 onset.(2, 4-6) URT specimens may also have detectable RNA during the pre-symptomatic 79 period(7), and pediatric patients who remain asymptomatic through the entire course of 80 on June 9, 2020 by guest http://jcm.asm.org/ Downloaded from 4 infection can persistently shed RNA in URT specimens for two weeks or longer.(4, 8) 81 Importantly, NPS may have higher viral loads than OPS.(6) Lower respiratory tract (LRT) 82 specimens including sputum(7, 9) and tracheal aspirates(10) (TA) are often positive for RNA 83 early in disease and remain positive longer than URT sources.(5) 84 NAATs are...
Rapid and severe Covid-19 pneumonia with severe acute chest syndrome in a sickle cell patient successfully treated with tocilizumab.
Indeterminate hepatitis C virus (HCV) third-generation recombinant immunoblot assay (RIBA3.0; Ortho Diagnostic Systems) patterns were arbitrarily defined by the manufacturer as the detection of only one antibody out of the four that were sought, namely, c100 (NS4 encoded), c22 (core encoded), c33c (NS3 encoded), and NS5 (NS5 encoded). The aims of the present study were (i) to determine the prevalence of indeterminate RIBA3.0 patterns in patients consecutively tested for anti-HCV antibodies in a university hospital; (ii) to evaluate the significance of these patterns in terms of viral replication, liver disease, and risk factors for HCV; and (iii) to get an insight into the mechanism underlying this peculiar immune response. Among 3,074 serum samples consecutively tested for anti-HCV antibodies, 588 were found to be positive by screening assays. Fifty-nine of them (10%) were RIBA3.0 indeterminate and were compared with 59 RIBA3.0-positive ones. Thirty-one RIBA3.0-indeterminate and 53 RIBA3.0-positive serum samples were HCV RNA positive by PCR (53 versus 90%; P < 10 ؊6). RIBA3.0-indeterminate and RIBA3.0-positive patients with positive PCR results were not significantly different for the prevalence of risk factors for HCV infection and elevated serum alanine aminotransferase activities. Immunosuppression, attributable to coexisting human immunodeficiency virus infection, organ transplantation, or the administration of immunosuppressive drugs, was significantly more frequent in PCR-positive, RIBA3.0-indeterminate patients than in PCR-negative, RIBA3.0-indeterminate patients (P < 0.001) and PCR-positive patients with a positive RIBA3.0 result (P < 0.01). The distribution of HCV genotypes did not differ significantly between HCV RNA-positive patients with indeterminate or positive RIBA3.0 results. In conclusion, the prevalence of indeterminate RIBA3.0 patterns in virology laboratories is about 10%; in about half of these patients HCV replication is detected by PCR; the main factor responsible for indeterminate RIBA3.0 patterns could be immunosuppression, whereas HCV genotypes do not seem to play a major role.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.