Abstract-This contribution addresses the extraction of atrial activity (AA) from real electrocardiogram (ECG) recordings of atrial fibrillation (AF). We show the appropriateness of independent component analysis (ICA) to tackle this biomedical challenge when regarded as a blind source separation (BSS) problem. ICA is a statistical tool able to reconstruct the unobservable independent sources of bioelectric activity which generate, through instantaneous linear mixing, a measurable set of signals. The three key hypothesis that make ICA applicable in the present scenario are discussed and validated: 1) AA and ventricular activity (VA) are generated by sources of independent bioelectric activity; 2) AA and VA present non-Gaussian distributions; and 3) the generation of the surface ECG potentials from the cardioelectric sources can be regarded as a narrow-band linear propagation process. To empirically endorse these claims, an ICA algorithm is applied to recordings from seven patients with persistent AF. We demonstrate that the AA source can be identified using a kurtosis-based reordering of the separated signals followed by spectral analysis of the sub-Gaussian sources. In contrast to traditional methods, the proposed BSS-based approach is able to obtain a unified AA signal by exploiting the atrial information present in every ECG lead, which results in an increased robustness with respect to electrode selection and placement.
The analysis and characterization of atrial tachyarrhythmias requires, in a previous step, the extraction of the atrial activity (AA) free from ventricular activity and other artefacts. This contribution adopts the blind source separation (BSS) approach to AA estimation from multilead electrocardiograms (ECGs). Previously proposed BSS methods for AA extraction--e.g., independent component analysis (ICA)--exploit only the spatial diversity introduced by the multiple spatially-separated electrodes. However, AA typically shows certain degree of temporal correlation, with a narrowband spectrum featuring a main frequency peak around 3.5-9 Hz. Taking advantage of this observation, we put forward a novel two-step BSS-based technique which exploits both spatial and temporal information contained in the recorded ECG signals. The spatiotemporal BSS algorithm is validated on simulated and real ECGs from a significant number of atrial fibrillation (AF) and atrial flutter (AFL) episodes, and proves consistently superior to a spatial-only ICA method. In simulated ECGs, a new methodology for the synthetic generation of realistic AF episodes is proposed, which includes a judicious comparison between the known AA content and the estimated AA sources. Using this methodology, the ICA technique obtains correlation indexes of 0.751, whereas the proposed approach obtains a correlation of 0.830 and an error in the estimated signal reduced by a factor of 40%. In real ECG recordings, we propose to measure performance by the spectral concentration (SC) around the main frequency peak. The spatiotemporal algorithm outperforms the ICA method, obtaining a SC of 58.8% and 44.7%, respectively.
Atrial fibrillation (AF) is the most common arrhythmia encountered in clinical practice. Neither the natural history of AF nor its response to therapy is sufficiently predictable by clinical and echocardiographic parameters. The purpose of this article is to describe technical aspects of novel electrocardiogram (ECG) analysis techniques and to present research and clinical applications of these methods for characterization of both the fibrillatory process and the ventricular response during AF. Atrial fibrillatory frequency (or rate) can reliably be assessed from the surface ECG using digital signal processing (extraction of atrial signals and spectral analysis). This measurement shows large inter-individual variability and correlates well with intra-atrial cycle length, a parameter which appears to have primary importance in AF maintenance and response to therapy. AF with a low fibrillatory rate is more likely to terminate spontaneously and responds better to antiarrhythmic drugs or cardioversion, whereas high-rate AF is more often persistent and refractory to therapy. Ventricular responses during AF can be characterized by a variety of methods, which include analysis of heart rate variability, RR-interval histograms, Lorenz plots, and non-linear dynamics. These methods have all shown a certain degree of usefulness, either in scientific explorations of atrioventricular (AV) nodal function or in selected clinical questions such as predicting response to drugs, cardioversion, or AV nodal modification. The role of the autonomic nervous system for AF sustenance and termination, as well as for ventricular rate responses, can be explored by different ECG analysis methods. In conclusion, non-invasive characterization of atrial fibrillatory activity and ventricular response can be performed from the surface ECG in AF patients. Different signal processing techniques have been suggested for identification of underlying AF pathomechanisms and prediction of therapy efficacy.
The proper analysis and characterization of atrial fibrillation (AF) from surface electrocardiographic (ECG) recordings requires to cancel out the ventricular activity (VA), which is composed of the QRS complex and the T wave. Historically, for single-lead ECGs, the averaged beat subtraction (ABS) has been the most widely used technique. However, this method is very sensitive to QRST wave variations and, moreover, high-quality cancelation templates may be difficult to obtain when only short length and single-lead recordings are available. In order to overcome these limitations, a new QRST cancelation method based on adaptive singular value cancelation (ASVC) applied to each single beat is proposed. In addition, an exhaustive study about the optimal set of complexes for better cancelation of every beat is also presented for the first time. The whole study has been carried out with both simulated and real AF signals. For simulated AF, the cancelation performance was evaluated making use of a cross-correlation index and the normalized mean square error (nmse) between the estimated and the original atrial activity (AA). For real AF signals, two additional new parameters were proposed. First, the ventricular residue (VR) index estimated the presence of ventricular activity in the extracted AA. Second, the similarity (S) evaluated how the algorithm preserved the AA segments out of the QRST interval. Results indicated that for simulated AF signals, mean correlation, nmse, VR and S values were 0.945 +/- 0.024, 0.332 +/- 0.073, 1.552 +/- 0.386 and 0.986 +/- 0.012, respectively, for the ASVC method and 0.866 +/- 0.042, 0.424 +/- 0.120, 2.161 +/- 0.564 and 0.922 +/- 0.051 for ABS. In the case of real signals, the mean VR and S values were 1.725 +/- 0.826 and 0.983 +/- 0.038, respectively, for ASVC and 3.159 +/- 1.097 and 0.951 +/- 0.049 for ABS. Thus, ASVC provides a more accurate beat-to-beat ventricular QRST representation than traditional techniques. As a consequence, VA cancelation is optimized and the AA can be extracted more precisely. Finally, the study has proven that optimal VA cancelation is achieved when a number between 20 and 30 complexes is selected following a correlation-based strategy.
This work introduces a new single-lead ECG delineator based on phasor transform. The method is characterized by its robustness, low computational cost and mathematical simplicity. It converts each instantaneous ECG sample into a phasor, and can precisely manage P and T waves, which are of notably lower amplitude than the QRS complex. The method has been validated making use of synthesized and real ECG sets, including the MIT-BIH arrhythmia, QT, European ST-T and TWA Challenge 2008 databases. Experiments with the synthesized recordings reported precise detection and delineation performances in a wide variety of ECGs, with signal-to-noise ratios of 10 dB and above. For real ECGs, the QRS detection was characterized by an average sensitivity of 99.81% and positive predictivity of 99.89%, for all the analyzed databases (more than one million beats). Regarding delineation, the maximum localization error between automatic and manual annotations was lower than 6 ms and its standard deviation was in agreement with the accepted tolerances for expert physicians in the onset and offset identification for QRS, P and T waves. Furthermore, after revising and reannotating some ECG recordings by expert cardiologists, the delineation error decreased notably, becoming lower than 3.5 ms, on average, and reducing by a half its standard deviation. This new proposed strategy outperforms the results provided by other well-known delineation algorithms and, moreover, presents a notably lower computational cost.
The fWP has proved to predict long-standing AF early recurrence after ECV and can be combined with SampEn to improve its diagnostic ability. Furthermore, a thorough analysis of the results allowed outlining possible associations between these two features and the concomitant status of atrial remodeling.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.