SummaryBackgroundLocalised prostate cancer is commonly treated with external-beam radiotherapy. Moderate hypofractionation has been shown to be non-inferior to conventional fractionation. Ultra-hypofractionated stereotactic body radiotherapy would allow shorter treatment courses but could increase acute toxicity compared with conventionally fractionated or moderately hypofractionated radiotherapy. We report the acute toxicity findings from a randomised trial of standard-of-care conventionally fractionated or moderately hypofractionated radiotherapy versus five-fraction stereotactic body radiotherapy for low-risk to intermediate-risk localised prostate cancer.MethodsPACE is an international, phase 3, open-label, randomised, non-inferiority trial. In PACE-B, eligible men aged 18 years and older, with WHO performance status 0–2, low-risk or intermediate-risk prostate adenocarcinoma (Gleason 4 + 3 excluded), and scheduled to receive radiotherapy were recruited from 37 centres in three countries (UK, Ireland, and Canada). Participants were randomly allocated (1:1) by computerised central randomisation with permuted blocks (size four and six), stratified by centre and risk group, to conventionally fractionated or moderately hypofractionated radiotherapy (78 Gy in 39 fractions over 7·8 weeks or 62 Gy in 20 fractions over 4 weeks, respectively) or stereotactic body radiotherapy (36·25 Gy in five fractions over 1–2 weeks). Neither participants nor investigators were masked to allocation. Androgen deprivation was not permitted. The primary endpoint of PACE-B is freedom from biochemical or clinical failure. The coprimary outcomes for this acute toxicity substudy were worst grade 2 or more severe Radiation Therapy Oncology Group (RTOG) gastrointestinal or genitourinary toxic effects score up to 12 weeks after radiotherapy. Analysis was per protocol. This study is registered with ClinicalTrials.gov, NCT01584258. PACE-B recruitment is complete and follow-up is ongoing.FindingsBetween Aug 7, 2012, and Jan 4, 2018, we randomly assigned 874 men to conventionally fractionated or moderately hypofractionated radiotherapy (n=441) or stereotactic body radiotherapy (n=433). 432 (98%) of 441 patients allocated to conventionally fractionated or moderately hypofractionated radiotherapy and 415 (96%) of 433 patients allocated to stereotactic body radiotherapy received at least one fraction of allocated treatment. Worst acute RTOG gastrointestinal toxic effect proportions were as follows: grade 2 or more severe toxic events in 53 (12%) of 432 patients in the conventionally fractionated or moderately hypofractionated radiotherapy group versus 43 (10%) of 415 patients in the stereotactic body radiotherapy group (difference −1·9 percentage points, 95% CI −6·2 to 2·4; p=0·38). Worst acute RTOG genitourinary toxicity proportions were as follows: grade 2 or worse toxicity in 118 (27%) of 432 patients in the conventionally fractionated or moderately hypofractionated radiotherapy group versus 96 (23%) of 415 patients in the stereotactic body radioth...
This is the author manuscript accepted for publication and has undergone full peer review but has not been through the copyediting, typesetting, pagination and proofreading process, which may lead to differences between this version and the Version of Record. Please cite this article as
To establish whether maintenance lapatinib after first-line chemotherapy is beneficial in human epidermal growth factor receptor (HER) 1/HER2-positive metastatic urothelial bladder cancer (UBC).
MethodsPatients with metastatic UBC were screened centrally for HER1/HER2 overexpression. Patients who screened positive for HER1/2 and who did not have progressive disease during chemotherapy (four to eight cycles) were randomly assigned one to one to lapatinib or placebo after completion of first-line/initial chemotherapy for metastatic disease. The primary end point was progression-free survival (PFS).
ResultsBetween 2007 and 2013, 446 patients with UBC were screened, and 232 with HER1-or HER2-positive disease were randomly assigned. The median PFS for lapatinib and placebo was 4.5 (95% CI, 2.8 to 5.4) and 5.1 (95% CI, 3.0 to 5.8) months, respectively (hazard ratio, 1.07; 95% CI, 0.81 to 1.43; P = .63). The overall survival for lapatinib and placebo was 12.6 (95% CI, 9.0 to 16.2) and 12.0 (95% CI, 10.5 to 14.9) months, respectively (hazard ratio, 0.96; 95% CI, 0.70 to 1.31; P = .80). Discontinuation due to adverse events were similar in both arms (6% lapatinib and 5% placebo). The rate of grade 3 to 4 adverse events for lapatinib and placebo was 8.6% versus 8.1% (P = .82). Preplanned subset analysis of patients strongly positive for HER1/HER2 (3+ on immunohistochemistry; n = 111), patients positive for only HER1 (n = 102), and patients positive for only HER2 (n = 42) showed no significant benefit with lapatinib in terms of PFS and overall survival (P . .05 for each).
ConclusionThis trial did not find significant improvements in outcome by the addition of maintenance lapatinib to standard of care.J Clin Oncol 35:48-55.
Purpose
To establish the toxicity profile of high-dose pelvic lymph node intensity-modulated radiation therapy (IMRT) and to assess whether it is safely deliverable at multiple centers.
Methods and Materials
In this phase 2 noncomparative multicenter trial, 124 patients with locally advanced, high-risk prostate cancer were randomized between prostate-only IMRT (PO) (74 Gy/37 fractions) and prostate and pelvic lymph node IMRT (P&P; 74 Gy/37 fractions to prostate, 60 Gy/37 fractions to pelvis). The primary endpoint was acute lower gastrointestinal (GI) Radiation Therapy Oncology Group (RTOG) toxicity at week 18, aiming to exclude a grade 2 or greater (G2+) toxicity-free rate of 80% in the P&P group. Key secondary endpoints included patient-reported outcomes and late toxicity.
Results
One hundred twenty-four participants were randomized (62 PO, 62 P&P) from May 2011 to March 2013. Median follow-up was 37.6 months (interquartile range [IQR], 35.4-38.9 months). Participants had a median age of 69 years (IQR, 64-74 years) and median diagnostic prostate-specific androgen level of 21.6 ng/mL (IQR, 11.8-35.1 ng/mL). At week 18, G2+ lower GI toxicity-free rates were 59 of 61 (96.7%; 90% confidence interval [CI], 90.0-99.4) for the PO group and 59 of 62 (95.2%; 90% CI, 88.0-98.7) for the P&P group. Patients in both groups reported similarly low Inflammatory Bowel Disease Questionnaire symptoms and Vaizey incontinence scores. The largest difference occurred at week 6 with 4 of 61 (7%) and 16 of 61 (26%) PO and P&P patients, respectively, experiencing G2+ toxicity. At 2 years, the cumulative proportion of RTOG G2+ GI toxicity was 16.9% (95% CI, 8.9%-30.9%) for the PO group and 24.0% (95% CI, 8.4%-57.9%) for the P&P group; in addition, RTOG G2+ bladder toxicity was 5.1% (95% CI, 1.7%-14.9%) for the PO group and 5.6% (95% CI, 1.8%-16.7%) for the P&P group.
Conclusions
PIVOTAL demonstrated that high-dose pelvic lymph node IMRT can be delivered at multiple centers with a modest side effect profile. Although safety data from the present study are encouraging, the impact of P&P IMRT on disease control remains to be established.
BackgroundThe use of magnetic resonance (MR) imaging as a part of preparation for radiotherapy is increasing. For delineation of the prostate several publications have shown decreased delineation variability using MR compared to computed tomography (CT). The purpose of the present work was to investigate the intra- and inter-physician delineation variability for prostate and seminal vesicles, and to investigate the influence of different MR sequence settings used clinically at the five centers participating in the study.MethodsMR series from five centers, each providing five patients, were used. Two physicians from each center delineated the prostate and the seminal vesicles on each of the 25 image sets. The variability between the delineations was analyzed with respect to overall, intra- and inter-physician variability, and dependence between variability and origin of the MR images, i.e. the MR sequence used to acquire the data.ResultsThe intra-physician variability in different directions was between 1.3 - 1.9 mm and 3 – 4 mm for the prostate and seminal vesicles respectively (1 std). The inter-physician variability for different directions were between 0.7 – 1.7 mm and approximately equal for the prostate and seminal vesicles. Large differences in variability were observed for individual patients, and also for individual imaging sequences used at the different centers. There was however no indication of decreased variability with higher field strength.ConclusionThe overall delineation variability is larger for the seminal vesicles compared to the prostate, due to a larger intra-physician variability. The imaging sequence appears to have a large influence on the variability, even for different variants of the T2-weighted spin-echo based sequences, which were used by all centers in the study.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.