The heat produced by optically excited gold nanorods is used to augment the chemotherapeutic agent cisplatin in killing tumor cells. This combined therapy kills 78% more cells than cisplatin alone, suggesting a synergistic interaction between these treatments.
The effects of the dielectric environment on the optical extinction spectra of gold nanorods were quantitatively studied using individual bare and silica-coated nanorods. The dispersion and amplitude of their extinction cross-section, dominated by absorption for the investigated sizes, were measured using spatial modulation spectroscopy (SMS). The experimental results were compared to calculations from a numerical model that included environmental features present in the measurements and the morphology and size of the corresponding nanorods measured by transmission electron microscopy. The combination of these experimental and theoretical tools permits a detailed interpretation of the optical properties of the individual nanorods. The measured optical extinction spectra and the extinction cross-section amplitudes were well reproduced by the numerical model for silica-coated gold nanorods, for which the silica shell provides a controlled environment. In contrast, additional environmental factors had to be assumed in the model for bare nanorods, stressing the importance of controlling and characterizing the experimental conditions when measuring the optical response of bare surface-deposited single metal nanoparticles.
In this paper, we perform a finite element (FE)-based numerical analysis to calculate the photoacoustic (PA) signal generated by spherical gold-silver (Au-Ag) alloy nanoparticles (NPs). These spherical particles are size-controlled and monodispersed, with tunable plasmonic resonance wavelength via change of the alloy composition. This enables their use in photoacoustic imaging as a contrast agent. This theoretical framework self consistently solves the electromagnetic, thermodynamic and transient acoustic pressure physics using a multiphysics coupling approach. We model our system as an optically heterogeneous medium irradiated by a nanosecond laser pulse in the tissue therapeutic optical window (NIR irradiation, with wavelength of 800 nm). We calculate the photoacoustic signal generated by the photo-thermal expansion of both the particle and its surrounding medium. The results show the impact of the gold molar fraction (GMF) of Au-Ag alloy NPs on the PA signal for different NP sizes. We show that significantly stronger PA signals are achieved using Au-Ag alloy NPs (GMF = 0.55) in comparison with pure AuNPs (GMF = 1) and pure AgNPs (GMF = 0) of the same size and shape.
The measurement of the ultrasound backscatter from individual micron-sized objects such as cells is required for various applications such as tissue characterization. However, performing such a measurement remains a challenge. For example, the presence of air bubbles in a suspension of cells during the measurements may lead to the incorrect interpretation of the acoustic signals. This work introduces a technique for measuring the ultrasound backscatter from individual micron-sized objects by combining a microinjection system with a co-registered optical microscope and an ultrasound imaging device. This allowed the measurement of the ultrasound backscatter response from a single object under optical microscope guidance. The optical and ultrasonic data were used to determine the size of the object and to deduce its backscatter responses, respectively. In order to calibrate the system, the backscatter frequency responses from polystyrene microspheres were measured and compared to theoretical predictions. A very good agreement was found between the measured backscatter responses of individual microspheres and theoretical predictions of an elastic sphere. The backscatter responses from single OCI-AML-5 cells were also investigated. It was found that the backscatter responses from AML cells are best modeled using the fluid sphere model. The advantages, limitations, and future applications of the developed technique are discussed.
Plasmonic gold nanorods (AuNRs) coated with four different thickness silver shells (AuNR\Ags) were synthesized and tested for their efficiency in Surface Enhanced Raman Scattering (SERS) signal enhancement for biomedical applications.
The flow characterization of blood through healthy and diseased flow geometries is of interest to researchers and clinicians alike, as it may allow for early detection, and monitoring, of cardiovascular disease. In this paper, we use a numerically efficient particle-based flow model called multiparticle collision dynamics (MPC for short) to study the effect of compressibility and slip of flow of a Newtonian fluid through a cylinder with a local constriction. We use a cumulative averaging method to compare our MPC results to the finite-element solution of the incompressible no-slip Navier-Stokes equations in the same geometry. We concentrate on low Reynolds number flows [[Formula: see text]] and quantify important differences observed between the MPC results and the Navier-Stokes solution in constricted geometries. In particular, our results show that upstream recirculating zones can form with the inclusion of slip and compressibility, which are not observed in the flow of an incompressible Newtonian fluid using the no-slip assumption, but have been observed experimentally for blood. Important flow features are also presented that could be used as indicators to observe compressibility and slip in experimental data where near-wall data may be difficult to obtain. Finally, we found that the cumulative averaging method used is ideal for steady particle-based flow methods, as macroscopic no-slip is readily obtained using the MPC bounce-back rule. Generally, a small spurious slip is seen using other averaging methods such as weighted spatial averages or averages over several runs, and the bounce-back rule has to be modified so as to achieve macroscopic no-slip. No modifications of the bounce-back rule were required for our simulations.
Surface modes of spherical objects subject to ultrasound excitation have been recently proposed to explain experimental measurements of scattering from microspheres and ultrasound contrast agents (UCAs). In this work, the relationship between surface modes and resonance frequencies of microspheres and UCAs is investigated. A finite-element model, built upon the fundamentals of wave propagation and structural mechanics, was introduced and validated against analytical solutions (error <5%). Numerical results showed the existence of a systematic relationship between resonance frequencies and surface modes of a 30 μm microsphere driven at 1-70 MHz. On the contrary, for a 100 nm shelled, 4 μm diameter UCA, no clear relationship between the resonance frequencies and the surface modes was found in the frequency range examined. Instead, the UCA exhibited a collection of complex oscillations, which appear to be a combination of various surface modes and displacements. A study of the effects of varying the shell properties on the backscatter showed the presence of peaks in the backscatter of thick-shelled UCAs, which are not predicted by previous models. In summary, this work presents a systematic effort to examine scattering and surface modes from ultrasound contrast agents using finite-element models.
Evidence suggests that compression and shear wave elastography are sensitive to the mechanical property changes occuring in dying cells following chemotherapy, and can hence be used to monitor cancer treatment response. A qualitative and quantitative understanding of the mechanical changes at the cellular level would allow to better infer how these changes affect macroscopic tissue mechanical properties and therefore allow the optimization of elastographic techniques (such as shear wave elastography) for the monitoring of cancer therapy. We used intracellular particle tracking microrheology (PTM) to investigate the mechanical property changes of cells exposed to paclitaxol, a mitotic inhibitor used in cancer chemotherapy. The average elastic and viscous moduli of the cytoplasm of treated MCF-7 breast cancer cells were calculated for frequency ranges between 0.2 and 100 rad s(-1) (corresponding to 0.03 and 15.92 Hz, respectively). A significant increase in the complex shear modulus of the cell cytoplasm was detected at 12 h post treatment. At 24 h after drug exposure, the elastic and viscous moduli increased by a total of 191.3 Pa (>8000×) and 9 Pa (∼9×), respectively for low frequency shear modulus measurements (at 1 rad s(-1)). At higher frequencies (10 rad s(-1)), the elastic and viscous moduli increased by 188.5 Pa (∼60×) and 1.7 Pa (∼1.1×), respectively. Our work demonstrates that PTM can be used to measure changes in the mechanical properties of treated cells and that cell elasticity significantly increases by 24 h after chemotherapy exposure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.