Design features and operation of a prototype miniaturized Fast Analyzer are described, and some results obtained with it are presented. The Analyzer occupies only one cubic foot of space. It has a 17-cuvet plastic rotor that rotates through a stationary optical system at speeds up to 5000 rpm. The resulting centrifugal force is utilized to transfer and mix a series of sample(s) and reagent(s) into the cuvets. The ensuing reactions are monitored spectrophotometrically, and the data evaluated in real time by an on-line computer. Samples (1 to 10 µl) and reagents (70 to 110 µl) are loaded into the rotor either discretely or dynamically; various rotor configurations can be used to do this. Many of the standard clinical analyses, including most of the NADH-linked enzymatic analyses, have been adapted for use with this analyzer. Precision obtained ranges from 1 to 4%. This report considers, specifically, analyses of some serum enzymes. Results show that the small analyzer possesses the previously demonstrated advantages of Fast Analyzers and, in addition, has several beneficial features arising from miniaturization.
A modified version of a previously described miniature Fast Analyzer [Clin. Chem. 18, 753 (1972)] was used as the basis for developing a compact, potentially portable, analytical system. This system includes an automated and versatile sample-reagent loader, a miniature Fast Analyzer, several plastic rotors and their cleaning station, and a portable data system. The sample-reagent loader combines a unique turntable assembly and two "Micromedic" pipets to quickly (5 min per rotor), accurately, and precisely obtain, transfer, and dispense small volumes of sample (1 to 10 µl of sample, 50 µl of diluent) and reagent (20 µl of reagent, 50 µl of diluent) into their respective cavities in a 17-cuvet rotor. The loader uses separate sample and reagent carousels, which allows operation of the system in either the single-sample—multiple-chemistry, multiple-sample— single-chemistry, or multiple-sample—multiple-chemistry analytical modes. The miniature Fast Analyzer rotates a loaded 17-cuvet rotor through a stationary optical system at speeds up to 5000 rpm. The resulting centrifugal force is used to mix and to transfer the discrete aliquots of sample(s) and reagent(s) into their respective cuvets. The ensuing reactions are monitored photometrically, and the data are processed in real time by either a portable Data Processor [Clin Chem. 18, 762 (1972)] or an on-line computer. A major improvement to the analyzer has been the addition of a temperature-control system that allows the temperature of the spinning rotor to be monitored and controlled to within ±0.2°C. After completion of an analytical run, the rotor is automatically washed and dried in the rotor cleaning station. Many of the standard clinical analyses, including most of the NADH-linked enzymatic analyses, have been adapted for use with this system.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.