The high incidence of Diabetes Mellitus in low-income regions has promoted the development of low-cost alternatives to replace blood-based procedures. In this work, we present a bienzymatic paper-based sensor suitable for the naked-eye detection of glucose in saliva samples. The sensor was obtained by a stamping procedure and modified with chitosan to improve the colorimetric readout. The bienzymatic reaction of GOx-HRP coupled with 2,4,6-tribromo-3-hydroxy benzoic acid was applied for the detection of glucose within a range from 0 to 180 mgdL−1 in buffer and artificial saliva solutions. The visual readout was perceived by the naked eye and registered with an office scanner to evaluate the analytical performance. The results showed a limit of detection of 0.37 mgdL−1 (S/N = 3) with an R.S.D. of 1.69% and a linear range from 1 to 22.5 mgdL−1 with an R2 of 0.99235. The analysis of human saliva samples was performed without pre-processing, achieving recoveries from 92 to 114%. The naked-eye detection was evaluated under two different light settings, showing average recoveries of 108.58 and 90.65% for standard and low illumination. The proposed device showed potential for easy-to-use, sensitive, low-cost, fast, and device-free detection of salivary glucose suitable for untrained personnel operation and limited facilities.
Glucose measurement is a fundamental tool in the daily care of Diabetes Mellitus (DM) patients and healthcare professionals. While there is an established market for glucose sensors, the rising number of DM cases has promoted intensive research to provide accurate systems for glucose monitoring. Polyaniline (PAni) is a conductive polymer with a linear conjugated backbone with sequences of single C–C and double C=C bonds. This unique structure produces attractive features for the design of sensing systems such as conductivity, biocompatibility, environmental stability, tunable electrochemical properties, and antibacterial activity. PAni-based glucose sensors (PBGS) were actively developed in past years, using either enzymatic or non-enzymatic principles. In these devices, PAni played roles as a conductive material for electron transfer, biocompatible matrix for enzymatic immobilization, or sensitive layer for detection. In this review, we covered the development of PBGS from 2015 to the present, and it is not even exhaustive; it provides an overview of advances and achievements for enzymatic and non-enzymatic PBGB PBGS for self-monitoring and continuous blood glucose monitoring. Additionally, the limitations of PBGB PBGS to advance into robust and stable technology and the challenges associated with their implementation are presented and discussed.
This study aimed to obtain a second-generation snack by extrusion from the by-product of rice milling enriched with amaranth. The raw material used was amaranth flour (AF), rice starch (NS) and modified rice starch (MS), which were evaluated by the analysis of substitution degree (SD), differential scanning calorimetry (DSC), viscosity (RVA), Fourier transform infrared spectroscopy (FT-IR) and X-ray diffraction (XRD). The snacks were expanded by extrusion and microwave oven, as a reference method. The samples were evaluated in hardness (D), expansion index (EI), apparent density (DAP), and protein content (P). Afterward, the optimized samples were evaluated by scanning electron microscopy (SEM) and resistant starch (RS). During the thermal characterization, a clear trend in the decrement in gelatinization temperatures was observed (78.35 to 63.90 °C in NS and MS respectively). The curves obtained in RVA analyses showed typical behavior of native (6.35 Pa.s) and extruded starches (2.88 Pa.s), with a significant decrease in viscosity peak. Through the analysis of FT-IR, the introduction of the functional acetyl group (stretching at a wavelength of 1735 cm−1) was corroborated. Snack samples results showed a maximum hardness in MS, with a value of 121 N, and the NS (100%) presented the highest EI value (1.41). The lowest DAP values were obtained for the MS (0.48 g/cm3, 100%) and AF (0.49 g/cm3, 100%) samples. P increased to a higher concentration of AF. In the optimum formulation, the SEM image showed that the expanded microwave sample increased the porosity and obtained an RS value of 8.2%. The formulation obtained in the present study presents high characteristics to be used in the development of a healthy snack.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.