Aim: The objective of this study was to evaluate the effects of solutions on the color stability of nanohybrid composite resins. Methods: The experimental sample consisted of 90 composite specimens (Beautifil II; Z350XT; Premisa), divided into three subgroups (n=10) according to the solutions (matte tea; lemon flavor isotonic drink; artificial saliva). The specimens were immersed in the solutions (5 mL/specimen) while stirring for 5 minutes, four times a day, with 1-hour intervals, repeated for 15 days. The color of the specimens was analyzed before (baseline) and after the 15th day of cycling using the CIELAB system. Data were analyzed using the two-way analysis of variance (ANOVA) and Tukey’s test (α=5%). Results: Different behaviors were observed among resins. Beautifil II presented the highest color change (∆E=4.18) and less color stability, statistically different from the others (p<.05). The solutions also presented different behaviors. The lemon flavor isotonic drink (∆E=3.95) promoted the highest color change, statistically different from saliva (∆E=2.75; p<.05). The interaction between Beautifil II and isotonic drink became even more evident and significant (p<.05). Conclusion: The isotonic drink is the solution that most affected the resins, and Beautifil II presents the worst color stability.
sempre fizeram de tudo para tornar cada sonho realidade. Não tenho palavras para explicar o tamanho do meu amor por vocês. Obrigada por sempre estarem na retaguarda enquanto trilho o meu caminho sozinha. Obrigada por sempre me porem para cima a cada tombo que eu levei. Vocês me ensinaram a não desistir, me ensinaram a fazer mesmo as coisas que eu não queria ou tinha medo por esforço. Vocês me ensinaram a ter coragem e me jogar no mundo, mesmo ele sendo assustador às vezes. Vocês sempre me ensinaram a me esforçar, batalhar e correr atrás do que eu quero, e é por isso que estou aqui hoje. Mil vezes obrigada por ter feito da nossa casa um lar, o meu porto seguro, um lugar para me amparar e voltar quando fosse preciso. Obrigada por todo o amor, às vezes na forma de um beijo e um abraço ou na forma de uma bronca. Vocês são o meu exemplo de superação. Aos meus irmãos, Arthur Barbosa Quero e Manoela Barbosa Quero, os maiores amores da minha vida. Vocês sempre torceram por mim me fazem querer ir mais longe e deixá-los orgulhosos. Cada um dos dois, com o seu jeitinho especial, faz com que eu me sinta amada e segura, pois eu sei que, independente de onde eu estiver, vocês vão me proteger e comprar uma briga por mim. Vocês são a minha inspiração e meus maiores modelos. Arthur, você me mostra que precisamos ser criativos e correr atrás daquilo que sonhamos, mesmo que a vida nos derrube às vezes. Ma, você me faz pensar fora da caixa, me mostra como o mundo pode ser diferente com amor e cada abraço que você me dá faz com que os meus medos vão embora. Obrigada por nunca saírem do meu lado, independente das brigas e dos desentendimentos.
Introduction:
It is still unclear whether the pretreatment for dentin hypersensitivity can interfere with the adhesive–dentin bonding strength. This study aimed to evaluate
in vitro
the effect of pretreatment with a casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) paste and diode laser on the shear bond strength of the etch-and-rinse adhesive system in the adhesive–dentin interface.
Materials and Methods:
Seventy-five bovine root specimens were randomly divided into five experimental groups (
n
= 15). Samples were eroded by six cycles of immersion in hydrochloric acid solution (0.01M; pH = 1.2) for 20 s each, at 45 min intervals, and treated with: G2 – no treatment, G3 – CPP-ACP, G4 – diode laser (970 nm), and G5 – CPP-ACP + Diode laser. After treatments, the morphology of the specimens was analyzed.
Results:
The fracture mode of each group was evaluated after restoration with composite resins in the treated area. Data were analyzed by the one-way ANOVA and Tukey's test (
P
< 0.05). G3 showed the highest values for shear bond strength; there was no significant difference among G1, G3, and G5 (
P
> 0.05). The adhesive fracture was predominant for all groups.
Conclusion:
The use of desensitizers containing CPP-ACP, associated or not with a diode laser, increased the bond strength of the etch-and-rinse adhesive system on eroded root dentin.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.