In recent years, the intrinsic magnetic properties of magnetic nanoparticles (MNPs) have made them one of the most promising candidates for magnetic resonance imaging (MRI). This study aims to evaluate the effect of different coating agents (with and without targeting agents) on the magnetic property of MNPs. In detail, iron oxide nanoparticles (IONPs) were prepared by the polyol method. The nanoparticles were then divided into two groups, one of which was coated with silica (SiO2) and hyperbranched polyglycerol (HPG) (SPION@SiO2@HPG); the other was covered by HPG alone (SPION@HPG). In the following section, folic acid (FA), as a targeting agent, was attached on the surface of nanoparticles. Physicochemical properties of nanostructures were characterized using Fourier transform infrared spectroscopy (FT-IR), transmission electron microscopy (TEM), and a vibrating sample magnetometer (VSM). TEM results showed that SPION@HPG was monodispersed with the average size of about 20 nm, while SPION@SiO2@HPG had a size of about 25 nm. Moreover, HPG coated nanoparticles had much lower magnetic saturation than the silica coated ones. The MR signal intensity of the nanostructures showed a relation between increasing the nanoparticle concentrations inside the MCF-7 cells and decreasing the signal related to the T2 relaxation time. The comparison of coating showed that SPION@SiO2@HPG (with/without a targeting agent) had significantly higher value in comparison to Fe3O4@HPG. Based on the results of this study, the Fe3O4@SiO2@HPG-FA nanoparticles have shown the best magnetic properties, and can be considered promising contrast agents for magnetic resonance imaging applications.
High-dose-rate (HDR) brachytherapy is a common method for cancer treatment in clinical brachytherapy. Because of the different source designs, there is a need for specific dosimetry data set for each HDR model. The purpose of this study is to obtain detailed dose rate distributions in water phantom for a first prototype HDR (192)Ir brachytherapy source model, IRAsource, and compare with the other published works. In this study, Monte Carlo N-particle (MCNP version 4C) code was used to simulate the dose rate distributions around the HDR source. A full set of dosimetry parameters reported by the American Association of Physicists in Medicine Task Group No. 43U1 was evaluated. Also, the absorbed dose rate distributions in water, were obtained in an along-away look-up table. The dose rate constant, Λ, of the IRAsource was evaluated to be equal to 1.112 ± 0.005 cGy h(-1) U(-1). The results of dosimetry parameters are presented in tabulated and graphical formats and compared with those reported from other commercially available HDR (192)Ir sources, which are in good agreement. This justifies the use of specific data sets for this new source. The results obtained in this study can be used as input data in the conventional treatment planning systems.
Purpose: To evaluate the effect of beam configuration with inaccurate or incomplete small field output factors on the accuracy of dose calculations in treatment planning systems. Methods: Output factors were measured using various detectors and for a range of field sizes. Three types of treatment machines were configured in two treatment planning systems. In the first (corrected) machine, the Exradin W1 scintillator was used to determine output factors. In the second (uncorrected) machine, the measured output factors by the A1SL ion chamber without considering output correction factors for small field sizes were utilized. In the third (clinical) machine, measured output factors by the Exradin W1 were used but not for field sizes smaller than 2 9 2 cm 2 . The dose computed by the anisotropic analytical algorithm (AAA), Acuros XB (AXB) and collapsed cone convolution/superposition (CCC) algorithms in the three machines were delivered using static (jaw-, MLC-, and jaw/MLC-defined), and composite [intensity modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT)] fields. The differences between measured and calculated dose values were analyzed. Results: For static fields, the percentage differences between measured and calculated doses by the three algorithms in three configured machines were <2% for field sizes larger than 2 9 2 cm 2 . In jaw-and jaw/MLC-defined fields smaller than 2 9 2 cm 2 , the corrected machine presented better agreement with measurement. Considering output correction factors in MLC-defined fields, among the three configured machines, the accuracy of calculation improved to within AE0.5%. For MLC-defined field size of 1 9 1 cm 2 , AXB showed the smallest percentage difference (1%). In IMRT and VMAT plans, the percentage differences between measured and calculated doses at the isocenter, as well as the gamma analysis of different plans, which include field sizes larger than 3 9 3 cm 2 , did not vary noticeably. For smaller field sizes, using the corrected machine influences dose calculation accuracy. Conclusion: Configuration with corrected output factors improves accuracy of dose calculation for static field sizes smaller than 2 9 2 cm 2 . For very small fields, the robustness of the dose calculation algorithm affects the accuracy of dose as well. In IMRT and VMAT plans, which include small subfields, the size of the jaw-defined field is an important factor and using corrected output factors increases dose calculation accuracy.
A Monte Carlo treatment plan verification (MCTPV) system was developed for clinical treatment plan verification (TPV), especially for the conformal and intensity-modulated radiotherapy (IMRT) plans. In the MCTPV, the MCNPX code was used for particle transport through the accelerator head and the patient body. MCTPV has an interface with TiGRT planning system and reads the information which is needed for Monte Carlo calculation transferred in digital image communications in medicine-radiation therapy (DICOM-RT) format. In MCTPV several methods were applied in order to reduce the simulation time. The relative dose distribution of a clinical prostate conformal plan calculated by the MCTPV was compared with that of TiGRT planning system. The results showed well implementation of the beams configuration and patient information in this system. For quantitative evaluation of MCTPV a two-dimensional (2D) diode array (MapCHECK2) and gamma index analysis were used. The gamma passing rate (3%/3 mm) of an IMRT plan was found to be 98.5% for total beams. Also, comparison of the measured and Monte Carlo calculated doses at several points inside an inhomogeneous phantom for 6- and 18-MV photon beams showed a good agreement (within 1.5%). The accuracy and timing results of MCTPV showed that MCTPV could be used very efficiently for additional assessment of complicated plans such as IMRT plan.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.