Effect of beam configuration with inaccurate or incomplete small field output factors on the accuracy of treatment planning dose calculation

Abstract: Purpose: To evaluate the effect of beam configuration with inaccurate or incomplete small field output factors on the accuracy of dose calculations in treatment planning systems. Methods: Output factors were measured using various detectors and for a range of field sizes. Three types of treatment machines were configured in two treatment planning systems. In the first (corrected) machine, the Exradin W1 scintillator was used to determine output factors. In the second (uncorrected) machine, the measured output … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(11 citation statements)
references
References 40 publications
0
11
0
Order By: Relevance
“…The monitor units are mainly affected by different output factor measurements, and the goal of this work was to evaluate relative dose only. The effect of different output factor data has been the subject of other works, mostly in the frame of small field management [ 14 , 18 , 29 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The monitor units are mainly affected by different output factor measurements, and the goal of this work was to evaluate relative dose only. The effect of different output factor data has been the subject of other works, mostly in the frame of small field management [ 14 , 18 , 29 ].…”
Section: Discussionmentioning
confidence: 99%
“…The dose calculation accuracy is the ability of the algorithm to estimate the dose distribution (energy deposition) in the medium [ 5 , 9 15 ]. However, there is a lack of studies evaluating the accuracy of the implementation of an algorithm in the planning system, except in the specific case of small field, where a lot of publications describe in detail the accuracy and the tuning of specific parameters [ 14 , 16 21 ].…”
Section: Introductionmentioning
confidence: 99%
“…7 When field sizes are smaller than 1 × 1 cm, 2 the robustness of the dose calculation algorithm becomes important. 7 Larraga-Gutierrez et al 8 measured MLC defined field output factors in a TrueBeam STx following TRS-483 5 recommendations, using four radiation detectors, to evaluate the AcurosXB algorithm in Eclipse TPS. The backup jaws were set at 0.5 cm larger than the MLC shaped fields.…”
Section: Introductionmentioning
confidence: 99%
“…They concluded that when jaw or jaw/MLC defined fields are smaller than 2 × 2 cm, using the corrected output factors improves the accuracy of dose calculation in all three algorithms. 7 When field sizes are smaller than 1 × 1 cm, 2 the robustness of the dose calculation algorithm becomes important. 7 Larraga-Gutierrez et al 8 measured MLC defined field output factors in a TrueBeam STx following TRS-483 5 recommendations, using four radiation detectors, to evaluate the AcurosXB algorithm in Eclipse TPS.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation