This study presents a column-switching solid-phase extraction online-coupled to a liquid chromatography/tandem mass spectrometry (SPE-LC-MS/MS) method for simultaneous analysis of 12 antibiotics (7 sulfonamides and 5 fluoroquinolones) and caffeine detected in the sewage and effluent of a pilot anaerobic reactor used in sewage treatment. After acidification and filtration, the samples were directly injected into a simple and conventional LC system. Backflush and foreflush modes were compared based on the theoretical plates and peak asymmetry observed. The method was tested in terms of detection (MDL) and quantification limit (MQL), linearity, relative recovery, and precision intra- and inter-day in lab-made sewage samples. The method presented suitable figures of merit in terms of detection, varying from 8.00 × 10(-5) to 6.00 × 10(-2) ng (0.800 up to 600 ng L(-1); caffeine) with direct injection volume of only 100 μL and 13 min of total analysis time (sample preparation and chromatographic run). When the method was applied in the analysis of sewage and effluent of the anaerobic reactor (n = 15), six antibiotics and caffeine were detected in concentrations ranging from 0.018 to 1097 μg L(-1). To guarantee a reliable quantification, standard addition was used to overcome the matrix effect.
A L-ascorbic acid biosensor based on ascorbate oxidase has been developed. The enzyme was extracted from the mesocarp of cucumber (Cucumis sativus) by using 0.05 mol L -1 phosphate buffer, pH 5.8 containing 0.5 mol L -1 NaCl. After the dialysis versus phosphate buffer 0.05 mol L -1 pH 5.8, the enzyme was immobilized onto nylon net through glutaraldehyde covalent bond. The membrane was coupled to an O 2 electrode and the yielding reaction monitored by oxygen depletion at -600 mV using flow injection analysis optimized to 0.1 mol L -1 phosphate buffer pH 5.8, as the carrier solution and flow-rate of 0.5 mL min -1 . The ascorbic acid calibration curve was linear from 1.2x10 -4 to 1.0x10 -3 mol L -1 . The evaluation of biosensor lifetime leads to 500 injections. Commercial pharmaceutical samples were analyzed with the proposed method and the results were compared with those obtained by high-performance liquid chromatography (HPLC).
The antibiotics sulfamethoxazole (SMTX) and ciprofloxacin (CIP) are commonly used in human and veterinary medicine, which explains their occurrence in wastewater. Anaerobic reactors are low-cost, simple and suitable technology to wastewater treatment, but there is a lack of studies related to the removal efficiency of antibiotics. To overcome this knowledge gap, the objective of this study was to evaluate the removal kinetics of SMTX and CIP using a horizontal-flow anaerobic immobilized biomass reactor. Two different concentrations were evaluated, for SMTX 20 and 40 μg L(-1); for CIP 2.0 and 5.0 μg L(-1). The affluent and effluent analysis was carried out in liquid chromatography/tandem mass spectrometry (LC-MS/MS) with the sample preparation procedure using an off-line solid-phase extraction. This method was developed, validated and successfully applied for monitoring the affluent and effluent samples. The removal efficiency found for both antibiotics at the two concentrations studied was 97%. Chemical oxygen demand (COD) exhibited kinetic constants that were different from that observed for the antibiotics, indicating the absence of co-metabolism. Also, though the antibiotic concentration was increased, there was no inhibitory effect in the removal of COD and antibiotics.
The use of anaerobic biomass attached to a support has been recently presented as a good prospect in the treatment of wastewater containing recalcitrant compounds, such as sulfamethazine (SMZ). SMZ has been found in swine wastewater and sewage treatment plants, which motivates assessing their degradation by new wastewater treatment technologies. Thus, this paper describes the use of a continuous fixed structured bed bioreactor for the purpose of evaluating SMZ removal kinetics present in lab-made wastewater. The analysis of SMZ used online solid-phase extraction coupled to liquid chromatography/tandem mass spectrometry (SPE online-LC-MS/MS). Chemical oxygen demand (COD) was also monitored to evaluate the organic matter removal. The bioreactor was operated under mesophilic conditions (30[Formula: see text]C), with a hydraulic retention time of 24 h. In order to evaluate SMZ removal, four different concentration levels were studied: 200, 400, 600, and 800 ng L. COD removal efficiency obtained for filtered effluent kept at 91.01% and there was no interference due to the increase of SMZ concentration. For SMZ, the removal efficiencies were of [Formula: see text] for 200 ng L concentration level; [Formula: see text] for 400 ng L; [Formula: see text] for 600 ng L, and [Formula: see text] for 800 ng L. COD removal kinetics presented a first-order apparent removal rate constant ([Formula: see text]) of [Formula: see text] h. SMZ also showed a first-order apparent removal rate constant of [Formula: see text] h for the following concentrations levels: 200, 400, 600, and 800 ng L.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.