Background: Biomechanical studies have suggested that the Kaplan fibers (KFs) of the iliotibial band play a role in controlling anterolateral rotation of the knee. There is a paucity of clinical information on whether injury to the KF in the setting of anterior cruciate ligament (ACL) rupture contributes to increased rotatory laxity of the knee. Purpose/Hypothesis: The purpose was to evaluate the association among radiological evidence of KF injury, intraoperative arthroscopic findings, and grade of pivot shift at the time of ACL reconstruction (ACLR). It was hypothesized that KF injury would be associated with increased injury to the lateral compartment of the knee and a higher grade of pivot shift. Study Design: Cohort study; Level of evidence, 3. Methods: A retrospective magnetic resonance imaging (MRI) analysis was conducted on 267 patients with ACL-injured knees who underwent primary ACLR. Patients who had MRI and surgery within 60 days of injury were included (mean age, 23.6 years); there were 158 (59.2%) male patients. MRI was performed using standard knee protocols, and diagnostic criteria were applied to identify KF injury. Associations were made among MRI findings, intraoperative findings, and grade of pivot shift with the patient examined under anesthesia at the time of ACLR. A comparison was made between patients with and without radiological evidence of KF injury. Results: The prevalence of KF injury was 17.6% (47/267 patients). Arthroscopic evidence of lateral meniscal injury was associated with KF injury (KF intact, 31%; KF injured, 55%; P = .010). The majority of patients in the intact and injured KF groups had a grade 2 pivot shift (75% and 70%, respectively). A minority had grade 3 pivot shift: 5% in the intact group versus 6.4% in the injured group. There was no association between radiological evidence of KF injury and pivot-shift grade ( P = .600). Conclusion: In acute ACL injury, KF injuries were not very common (17.6%), and the rate of grade 3 pivot shift was low (5.2%). When present, KF injuries were not associated with a higher-grade pivot shift. However, there was an association between KF injury and lateral meniscal tears identified at the time of ACLR. The role of KFS in controlling anterolateral rotatory laxity in the acute ACL injury in the clinical setting may be less evident when compared with the biomechanical setting.
Lateral extra-articular augmentation (LEA) of anterior cruciate ligament reconstructions significantly reduces graft failure rates. Currently, proximally fixed LEA procedures are popular techniques. However, there are concerns about these techniques regarding anterior cruciate ligament tunnel collision, kinematic overconstraint, and increasing lateral-compartment contact forces. These issues are potentially avoided by the modified Ellison procedure, which is a distally fixed LEA technique. This article describes the surgical details of this easily reproducible technique.
Intra-articular glenohumeral joint injections are commonly performed in the clinical setting for diagnostic and therapeutic purposes. Multiple approaches are described, including the anterior and posterior approaches and the less studied superomedial (Neviaser) approach. The purpose of this study was to determine the length of needle required to enter the shoulder joint via the Neviaser approach by radiography and magnetic resonance imaging (MRI) measurements. Additionally, the authors sought to identify any correlation between needle length and body mass index (BMI). They performed a retrospective review of 101 consecutive patients evaluated by one faculty member at their institution. Inclusion criteria were age older than 50 years, no previous shoulder surgery, no history of acromioclavicular joint injury, and having a true anteroposterior radiograph and MRI within 1 year of each other. Using a digital imaging system, the Neviaser approach needle path was drawn for both images, and the lengths were measured. Correlation coefficients for needle length and BMI were calculated. The images of 58 (57.4%) male patients and 43 (42.6%) female patients were evaluated (average BMI, 31.2 kg/m
2
). The average needle length measurement was 4.27 cm on radiograph and 3.9 cm on MRI. Correlation coefficients were
r
=0.36 (
P
=.0002) using radiographs and
r
=0.53 (
P
<.0001) using MRIs. When using the Neviaser approach, there is a moderate positive correlation between BMI and the measured distance between skin and the glenohumeral joint when assessed on MRI, and a weak positive correlation on radiographs. The authors conclude that an injection needle of 2 inches or greater is required to reliably access the shoulder joint, and this length may increase with increasing BMI. [
Orthopedics
. 2020;43(4):e215–e218.]
Therapeutic arthroscopy with microfracture leads to fibrocartilaginous repair and is an effective treatment of osteochondral lesions of the talus. A full diagnostic arthroscopy is performed, and then attention is turned to the osteochondral defect. We describe in detail patient positioning, ankle distraction, portal placement, steps of the diagnostic arthroscopy, and the technique of microfracture. We then discuss the special considerations to be taken regarding the use of a distractor, protection of neurovascular structures, and the indications for microfracture.A nkle arthroscopy has been commonly described with the patient in the supine position through the use of anteromedial and anterolateral portals. It can be performed under general, spinal, epidural, and even local anesthesia. It can be used as a diagnostic modality when a patient's pathology is unclear. It has been established as a viable modality of treatment for anterior impingement and osteochondral defects.
Therapeutic extra-articular hip endoscopy is an effective treatment of greater trochanteric sciatic nerve impingement. We describe in detail technical pearls of the procedure including positioning, portal placement, and steps to obtaining adequate decompression while avoiding iatrogenic nerve injury.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.