Combined checkpoint blockade (e.g., PD1/PD-L1) with traditional clinical therapies can be hampered by side effects and low tumour-therapeutic outcome, hindering broad clinical translation. Here we report a combined tumour-therapeutic modality based on integrating nanosonosensitizers-augmented noninvasive sonodynamic therapy (SDT) with checkpoint-blockade immunotherapy. All components of the nanosonosensitizers (HMME/R837@Lip) are clinically approved, wherein liposomes act as carriers to co-encapsulate sonosensitizers (hematoporphyrin monomethyl ether (HMME)) and immune adjuvant (imiquimod (R837)). Using multiple tumour models, we demonstrate that combining nanosonosensitizers-augmented SDT with anti-PD-L1 induces an anti-tumour response, which not only arrests primary tumour progression, but also prevents lung metastasis. Furthermore, the combined treatment strategy offers a long-term immunological memory function, which can protect against tumour rechallenge after elimination of the initial tumours. Therefore, this work represents a proof-of-concept combinatorial tumour therapeutics based on noninvasive tumours-therapeutic modality with immunotherapy.
ObjectiveTo evaluate the diagnostic value of acoustic radiation force impulse (ARFI) to test the elasticity of renal parenchyma by measuring the shear wave velocity (SWV) which might be used to detect chronic kidney disease (CKD).Methods327 healthy volunteers and 64 CKD patients were enrolled in the study. The potential influencing factors and measurement reproducibility were evaluated in the healthy volunteers. Correlations between SWV and laboratory tests were analyzed in CKD patients.?Receiver-operating characteristic curve (ROC) analyses were performed to assess the diagnostic performance of ARFI.ResultsThe SWV of healthy volunteers correlated significantly to age (r = −0.22, P<0.001, n = 327) and differed significantly between men and women (2.06±0.48 m/s vs. 2.2±0.52 m/s, P = 0.018, n = 327). However, it did not correlate significantly to height, weight, body mass index, waistline, kidney dimension and the depth for SWV measurement (n = 30). Inter- and intraobserver agreement expressed as intraclass coefficient correlation were 0.64 (95% CI: 0.13 to 0.82, P = 0.011) and 0.6 (95% CI: 0.31 to 0.81, P = 0.001) (n = 40). The mean SWV in healthy volunteers was 2.15±0.51 m/s, while was 1.81±0.43 m/s, 1.79±0.29 m/s, 1.81±0.44 m/s, 1.64±0.55 m/s, and 1.36±0.17 m/s for stage 1, 2, 3, 4 and 5 in CKD patients respectively. The SWV was significantly higher for healthy volunteers compared with each stage in CKD patients. ARFI could not predict the different stages of CKD except stage 5. In CKD patients, SWV correlated to e-GFR (r = 0.3, P = 0.018), to urea nitrogen (r = −0.3, P = 0.016), and to creatinine (r = −0.41, P = 0.001). ROC analyses indicated that the area under the ROC curve was 0.752 (95% CI: 0.704 to 0.797) (P<0.001). The cut-off value for predicting CKD was 1.88 m/s (sensitivity 71.87% and specificity 69.69%).ConclusionARFI may be a potentially useful tool in detecting CKD.
Inspired by considerable application potential in various diseases, nitric oxide (NO) has gained increasing attention. Nevertheless, current NO release scaffolds suffer from some inevitable drawbacks, for example, high toxicity for NO donor byproducts, poor specificity, shallow penetration depth, and strong ionizing irradiation for triggers, all of which remain obstacles to clinical application. Herein, an ultrasound-triggered NO on-demand release system is constructed using natural l-arginine as NO donor and local ultrasound as trigger. The focused ultrasound can activate HO to generate more oxygen-contained species (ROS) of stronger oxidation ability than HO for oxidizing LA via the energy transformation from ultrasound mechanical energy to chemical energy, and thus produce more NO for ultimately suppressing the highly aggressive and lethal Panc-1 tumor. Moreover, a blood vessel-intercellular matrix-cell "relay" targeting strategy has been established and relying on it, over 7-fold higher retention of such NO release system in a subcutaneous xenograft mouse model of Panc-1 is obtained, which consequently results in a more evident inhibitory effect and a prolonged survival rate (80% ± 5% improvement in 60-day survival).
This large multicenter study demonstrates differential prognostic risks of the three major PTC variants and establishes a unique risk order of TCPTC > CPTC ≫ FVPTC, providing important clinical implications for specific variant-based management of PTC.
ObjectiveVirtual touch tissue quantification (VTQ) of acoustic radiation force impulse (ARFI) is a new quantitative technique to measure tissue stiffness. The study was aimed to assess the usefulness of VTQ in the diagnosis of thyroid nodules.Methods173 pathologically proven thyroid nodules in 142 patients were included and all were examined by conventional ultrasound (US), conventional elasticity imaging (EI) and VTQ of ARFI. The tissue stiffness for VTQ was expressed as shear wave velocity (SWV) (m/s). Receiver-operating characteristic curve (ROC) analyses were performed to assess the diagnostic performance. Intra- and inter-observer reproducibility of VTQ measurement was assessed.ResultsThe SWVs of benign and malignant thyroid nodules were 2.34±1.17 m/s (range: 0.61–9.00 m/s) and 4.82±2.53 m/s (range: 2.32–9.00 m/s) respectively (P<0.001). The mean SWV ratios between each nodule and the adjacent thyroid tissue were 1.19±0.67 (range: 0.31–6.87) for benign and 2.50±1.54 (range: 0.85–6.69) for malignant nodules (P<0.001). ROC analyses indicated that the area under the curve was 0.861 (95% CI : 0.804, 0.918) (P<0.001) for SWV and 0.831(95% CI : 0.761, 0.900)(P<0.001) for the SWV ratio. The cutoff points for the differential diagnosis were 2.87 m/s for SWV and 1.59 for SWV ratio. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value for EI were 65.9%, 66.7%, 66.5%, 40.3%, and 85.1%, respectively, and were 63.6%–75%, 82.2%–88.4%, 80.3%–82.1%, 58.9%–65.1%, and 87.7%–90.5%, respectively, for VTQ. The diagnostic value of VTQ is the highest for nodules >20 mm and lowest for those ≤10 mm. The correlation coefficients were 0.904 for intraobserver measurement and 0.864 for interobserver measurement.ConclusionsVTQ of ARFI provides quantitative and reproducible information about the tissue stiffness, which is useful for the differentiation between benign and malignant thyroid nodules. The diagnostic performance of VTQ is higher than that of conventional EI.
Percutaneous microwave ablation and radiofrequency ablation are both effective methods in treating hepatocellular carcinomas. The local tumor control, complications related to treatment, and long-term survivals were equivalent for the two modalities.
Monodisperse, ultrasmall (<5 nm) Cu(2-x)S nanodots (u-Cu(2-x)S NDs) with significantly strong near-infrared absorption and conversion are successfully demonstrated for effective deep-tissue photoacoustic imaging-guided photothermal therapy both in vitro and in vivo. Owing to ultrasmall nanoparticle size and high water dispersibility as well as long stability, such nanodots possess a prolonged circulation in blood and good passive accumulation within tumors through the enhanced permeability and retention effect. These u-Cu(2-x)S NDs have negligible side effects to both blood and normal tissues according to in vivo toxicity evaluations for up to 3 months, showing excellent hemo/histocompatibility. Furthermore, these u-Cu(2-x)S NDs can be thoroughly cleared through feces and urine within 5 days, showing high biosafety for further potential clinical translation. This novel photoacoustic imaging-guided photothermal therapy based on u-Cu(2-x)S NDs composed of a single component shows great prospects as a multifunctional nanoplatform with integration and multifunction for cancer diagnosis and therapy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.