With stress echo (SE) 2020 study, a new standard of practice in stress imaging was developed and disseminated: the ABCDE protocol for functional testing within and beyond CAD. ABCDE protocol was the fruit of SE 2020, and is the seed of SE 2030, which is articulated in 12 projects: 1-SE in coronary artery disease (SECAD); 2-SE in diastolic heart failure (SEDIA); 3-SE in hypertrophic cardiomyopathy (SEHCA); 4-SE post-chest radiotherapy and chemotherapy (SERA); 5-Artificial intelligence SE evaluation (AI-SEE); 6-Environmental stress echocardiography and air pollution (ESTER); 7-SE in repaired Tetralogy of Fallot (SETOF) ; 8-SE in post-COVID-19 (SECOV); 9: Recovery by stress echo of conventionally unfit donor good hearts (RESURGE); 10-SE for mitral ischemic regurgitation (SEMIR); 11-SE in valvular heart disease (SEVA); 12-SE for coronary vasospasm (SESPASM). The study aims to recruit in the next 5 years (2021–2025) ≥10,000 patients followed for ≥5 years (up to 2030) from ≥20 quality-controlled laboratories from ≥10 countries. In this COVID-19 era of sustainable health care delivery, SE2030 will provide the evidence to finally recommend SE as the optimal and versatile imaging modality for functional testing anywhere, any time, and in any patient.
Inter-atrial and inter-ventricular electromechanical delays can be predicted from P-wave and QRS durations. These measurements allow AV delay optimization in DDD and cardiac resynchronization therapy devices with no need of Doppler echocardiography.
Background: Lung ultrasound detects pulmonary congestion as B-lines at rest, and more frequently, during exercise stress echocardiography (ESE). Methods: We performed ESE plus lung ultrasound (4-site simplified scan) in 4392 subjects referred for semi-supine bike ESE in 24 certified centers in 9 countries. B-line score ranged from 0 (normal) to 40 (severely abnormal). Five different populations were evaluated: control subjects (n=103); chronic coronary syndromes (n=3701); heart failure with reduced ejection fraction (n=395); heart failure with preserved ejection fraction (n=70); ischemic mitral regurgitation ≥ moderate at rest (n=123). In a subset of 2478 patients, follow-up information was available. Results: During ESE, B-lines increased in all study groups except controls. Age, hypertension, abnormal ejection fraction, peak wall motion score index, and abnormal heart rate reserve were associated with B-lines in multivariable regression analysis. Stress B lines (hazard ratio, 2.179 [95% CI, 1.015–4.680]; P =0.046) and ejection fraction <50% (hazard ratio, 2.942 [95% CI, 1.268–6.822]; P =0.012) were independent predictors of all-cause death (n=29 after a median follow-up of 29 months). Conclusions: B-lines identify the pulmonary congestion phenotype at rest, and more frequently, during ESE in ischemic and heart failure patients. Stress B-lines may help to refine risk stratification in these patients. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT 03049995.
Background: Two-dimensional volumetric exercise stress echocardiography (ESE) provides an integrated view of left ventricular (LV) preload reserve through end-diastolic volume (EDV) and LV contractile reserve (LVCR) through end-systolic volume (ESV) changes. Purpose: To assess the dependence of cardiac reserve upon LVCR, EDV, and heart rate (HR) during ESE. Methods: We prospectively performed semi-supine bicycle or treadmill ESE in 1344 patients (age 59.8 ± 11.4 years; ejection fraction = 63 ± 8%) referred for known or suspected coronary artery disease. All patients had negative ESE by wall motion criteria. EDV and ESV were measured by biplane Simpson rule with 2-dimensional echocardiography. Cardiac index reserve was identified by peak-rest value. LVCR was the stress-rest ratio of force (systolic blood pressure by cuff sphygmomanometer/ESV, abnormal values ≤2.0). Preload reserve was defined by an increase in EDV. Cardiac index was calculated as stroke volume index * HR (by EKG). HR reserve (stress/rest ratio) <1.85 identified chronotropic incompetence. Results: Of the 1344 patients, 448 were in the lowest tertile of cardiac index reserve with stress. Of them, 303 (67.6%) achieved HR reserve <1.85; 252 (56.3%) had an abnormal LVCR and 341 (76.1%) a reduction of preload reserve, with 446 patients (99.6%) showing ≥1 abnormality. At binary logistic regression analysis, reduced preload reserve (odds ratio [OR]: 5.610; 95% confidence intervals [CI]: 4.025 to 7.821), chronotropic incompetence (OR: 3.923, 95% CI: 2.915 to 5.279), and abnormal LVCR (OR: 1.579; 95% CI: 1.105 to 2.259) were independently associated with lowest tertile of cardiac index reserve at peak stress. Conclusions: Heart rate assessment and volumetric echocardiography during ESE identify the heterogeneity of hemodynamic phenotypes of impaired chronotropic, preload or LVCR underlying a reduced cardiac reserve.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.