Purpose : Monte Carlo methods are considered the gold standard for dosimetric computations in radiotherapy. Their execution time is however still an obstacle to the routine use of Monte Carlo packages in a clinical setting. To address this problem, a completely new, and designed from the ground up for the GPU, Monte Carlo dose calculation package for voxelized geometries is proposed: GPUMCD.Method : GPUMCD implements a coupled photon-electron Monte Carlo simulation for energies in the range 0.01 MeV to 20 MeV. An analogue simulation of photon interactions is used and a Class II condensed history method has been implemented for the simulation of electrons. A new GPU random number generator, some divergence reduction methods as well as other optimization strategies are also described. GPUMCD was run on a NVIDIA GTX480 while single threaded implementations of EGSnrc and DPM were run on an Intel Core i7 860.Results : Dosimetric results obtained with GPUMCD were compared to EGSnrc. In all but one test case, 98% or more of all significant voxels passed a gamma criteria of 2%-2mm. In terms of execution speed and efficiency, GPUMCD is more than 900 times faster than EGSnrc and more than 200 times faster than DPM, a Monte Carlo package aiming fast executions. Absolute execution times of less than 0.3 s are found for the simulation of 1M electrons and 4M photons in water for monoenergetic beams of 15 MeV, including GPU-CPU memory transfers.Conclusion : GPUMCD, a new GPU-oriented Monte Carlo dose calculation platform, has been compared to EGSnrc and DPM in terms of dosimetric results and execution speed. Its accuracy and speed make it an interesting solution for full Monte Carlo dose calculation in radiation oncology.
Radiochromic film is a dosimeter of choice in applications requiring high spatial resolution, two dimensional measurements, or minimum perturbation of the beam fluence. Since the measurement uncertainty in Gafchromic film dosimetry is thought to be significant compared to that of ionization chambers, a rigorous method to evaluate measurement uncertainties is desired. This article provides a method that takes into account the correlation between fit parameters as well as single dose values in order to obtain accurate uncertainties in absolute and relative measurements. A complete portrait of all sources of uncertainty in Gafchromic film dosimetry is given. The parametrization of variance as a function of the number of averaged pixels is obtained in order to accurately predict the uncertainty as a function of the size of the region of interest. The choice of functional form for the sensitometric curve is based on four criteria and a convergence of global net optical density uncertainty to 0.0013 is demonstrated. A minimum number of 12 points is recommended to characterize the sensitometric curve to a sufficient precision on the uncertainty estimation. Uncertainty levels of 0.9% on absolute dose measurements and 0.45% on relative measurements are achieved using a 12-point calibration curve with 220 cGy and repeating measurements five times. Uncertainties of 0.8% and 0.4% are achievable when using 35 points during film characterization. Ignoring covariance terms is shown to lead to errors in the estimation of uncertainty.
To develop a general method for human tissue characterization with dual- and multi-energy CT and evaluate its performance in determining elemental compositions and quantities relevant to radiotherapy Monte Carlo dose calculation. Ideal materials to describe human tissue are obtained applying principal component analysis on elemental weight and density data available in literature. The theory is adapted to elemental composition for solving tissue information from CT data. A novel stoichiometric calibration method is integrated to the technique to make it suitable for a clinical environment. The performance of the method is compared with two techniques known in literature using theoretical CT data. In determining elemental weights with dual-energy CT, the method is shown to be systematically superior to the water-lipid-protein material decomposition and comparable to the parameterization technique. In determining proton stopping powers and energy absorption coefficients with dual-energy CT, the method generally shows better accuracy and unbiased results. The generality of the method is demonstrated simulating multi-energy CT data to show the potential to extract more information with multiple energies. The method proposed in this paper shows good performance to determine elemental compositions from dual-energy CT data and physical quantities relevant to radiotherapy dose calculation. The method is particularly suitable for Monte Carlo calculations and shows promise in using more than two energies to characterize human tissue with CT.
DECT has a clear potential to improve proton beam range predictions over SECT in proton therapy. However, in the current state high levels of noise remain problematic for DECT characterization methods and do not allow getting the full benefits of this technology. Future work should focus on adapting DECT methods to noise and investigate methods based on raw-data to reduce CT artifacts.
Purpose: For the purpose of nonstandard beam reference dosimetry, the current concept of reporting absorbed dose at a point in water located at a representative position in the chamber volume is investigated in detail. As new nonstandard beam reference dosimetry protocols are under development, an evaluation of the role played by the definition of point of measurement could lead to conceptual improvements prior to establishing measurement procedures. Methods: The present study uses the current definition of reporting absorbed dose to calculate ionization chamber perturbation factors for two cylindrical chamber models ͑Exradin A12 and A14͒ using the Monte Carlo method. The EGSnrc based user-code EGSគchamber is used to calculate chamber dose responses of 14 IMRT beams chosen to cause considerable dose gradients over the chamber volume as previously used by Bouchard and Seuntjens ͓"Ionization chamber-based reference dosimetry of intensity modulated radiation beams," Med. Phys. 31͑9͒, 2454-5465 ͑2004͔͒. Results: The study shows conclusively the relative importance of each physical effect involved in the nonstandard beam correction factors of 14 IMRT beams. Of all correction factors involved in the dosimetry of the beams studied, the gradient perturbation correction factor has the highest magnitude, on average, 11% higher compared to reference conditions for the Exradin A12 chamber and about 5% higher for the Extradin A14 chamber. Other perturbation correction factors ͑i.e., P wall , P stem , and P cel ͒ are, on average, less than 0.8% different from reference conditions for the chambers and beams studied. The current approach of reporting measured absorbed dose at a point in water coinciding with the location of the centroid of the chamber is the main factor responsible for large correction factors in nonstandard beam deliveries ͑e.g., intensity modulated radiation therapy͒ reported in literature. Conclusions: To reduce or eliminate the magnitude of perturbation correction factors in nonstandard beam reference dosimetry, two possible ways to report absorbed dose are suggested: ͑1͒ Reporting average dose to the sensitive volume of the chamber filled with water, combined with removing the reference field implicit gradient effect when measuring output factors, and ͑2͒ reporting average dose to the chamber itself during output factor verifications. The first option could be adopted if clinical beam correction factors are negligible. The second option could simplify quality assurance procedures when correction factors are not negligible and have to be calculated using Monte Carlo simulations.
Quality correction factors of small megavoltage photon fields are mainly due to differences in electron density between water and the detector medium and to volume averaging over the detector cavity. Other effects, such as the presence of extracameral components and differences in atomic properties of the detection medium with respect to water, can also play an accentuated role in small photon fields compared to standard beams.
The present paper addresses reference dose measurements using thimble ionization chambers for quality assurance in IMRT fields. In these radiation fields, detector fluence perturbation effects invalidate the application of open-field dosimetry protocol data for the derivation of absorbed dose to water from ionization chamber measurements. We define a correction factor C(Q)IMRT to correct the absorbed dose to water calibration coefficient N(D, w)Q for fluence perturbation effects in individual segments of an IMRT delivery and developed a calculation method to evaluate the factor. The method consists of precalculating, using accurate Monte Carlo techniques, ionization chamber, type-dependent cavity air dose, and in-phantom dose to water at the reference point for zero-width pencil beams as a function of position of the pencil beams impinging on the phantom surface. These precalculated kernels are convolved with the IMRT fluence distribution to arrive at the dose-to-water-dose-to-cavity air ratio [D(a)w (IMRT)] for IMRT fields and with a 10x10 cm2 open-field fluence to arrive at the same ratio D(a)w (Q) for the 10x10 cm2 reference field. The correction factor C(Q)IMRT is then calculated as the ratio of D(a)w (IMRT) and D(a)w (Q). The calculation method was experimentally validated and the magnitude of chamber correction factors in reference dose measurements in single static and dynamic IMRT fields was studied. The results show that, for thimble-type ionization chambers the correction factor in a single, realistic dynamic IMRT field can be of the order of 10% or more. We therefore propose that for accurate reference dosimetry of complete n-beam IMRT deliveries, ionization chamber fluence perturbation correction factors must explicitly be taken into account.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.