Dixon's method of chemical shift imaging of a two-component system is modified and extended without requiring additional imaging time. The modified method allows one to obtain truly segregated fat and water images of animal tissues. This is accomplished by acquiring additional image data from which information about in situ magnetic field inhomogeneity and bulk magnetic susceptibility can be derived. Applications to various anatomic sections of the normal human body are illustrated. The method is compared with the standard Dixon technique of chemical shift image separation.
Objectives To determine the accuracy of calciumcontaining rings measurements imaged by threedimensional echocardiography (3DE), multi-slice CT (MSCT) and cardiac magnetic resonance (CMR) under ideal conditions against the true ring dimensions. To compare the accuracy of aortic annulus (AoA) measurements in ex vivo human hearts using 3DE, MSCT and CMR. To determine the accuracy of AoA measurements in an in vivo human model. Design 3DE, MSCT and CMR imaging were performed on 30 calcium-containing rings and 28 explanted human hearts. Additionally, 15 human subjects with clinical indication for MSCT underwent 3DE. Two experts in each modality measured the images. Main outcome measures Bias and intraclass correlation coefficient for accuracy of imaging measurements when compared with actual ring dimensions. Bias, intraclass correlation coefficient and variability were obtained: (1) when comparing explanted human heart AoA measurements from the two remaining imaging modalities with the most accurate one as determined from the ring measurements and (2) in in vivo human AoA measurements. Analysis was repeated on explanted heart subgroups divided by aortic valve Agatston score. Results Against the known ring dimensions, CMR had the highest accuracy and the lowest variability. MSCT measurements had high accuracy but wider variability and 3DE had the lowest accuracy with the largest variability. When 3DE and MSCT were compared with CMR, 3DE underestimated and MSCT overestimated AoA dimensions, but inter-measurement variability of 3DE and MSCT were similar. When divided by Agatston score, both 3DE and MSCT measurements were larger and showed greater variability with increasing calcium burden. The in vivo study showed that the correlation between 3DE and MSCT measurements was high; however, 3DE measurements were smaller than those measured with MSCT. Conclusions In the in vitro model, CMR measurements were the most accurate for assessing the actual dimensions suggesting that further investigations on its role in AoA measurement in TAVR are needed. However from the in vivo model, MSCT and 3DE are reasonable alternatives with the understanding that they can slightly overestimate and underestimate annular dimensions, respectively.
Magnetic resonance (MR) images and computed tomograms of 25 patients with head trauma were compared. MR proved to be superior in many ways for demonstrating extracerebral as well as intracerebral traumatic lesions. Isodense subdural hematomas, which present a diagnostic dilemma on CT images were clearly seen on MR, regardless of their varying CT densities. In a case of epidural hematoma, the dura mater was shown directly as nearly devoid of signal on MR. Direct coronal images provided excellent visualization of extracerebral collections along the peritentorial space and subtemporal area. In a patient with intracerebral hematoma, CT failed to demonstrate residual parenchymal changes in a 3-month follow-up study, but MR clearly depicted the abnormalities. The superiority of MR over CT was also well illustrated in a patient with post-traumatic osteomyelitis of the calvarium.
The usefulness of nuclear magnetic resonance (NMR) images in the evaluation of spinal disorders below the craniocervical junction was studied. Six normal subjects and 41 patients with various spinal abnormalities were examined. NMR proved capable of
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.