BackgroundThe sacrococcygeal morphology of Arabs and Europeans has been studied using computed tomography (CT) or magnetic resonance imaging to determine the cause of coccydynia. Studies have suggested differences in sacrococcygeal morphology among ethnic groups. However, there are no data on the sacrococcygeal anatomy of Koreans.MethodsWe conducted a retrospective analysis of 606 pelvic CT scans that were taken at Cheju Halla General Hospital between 2008 and 2014. Fractures of the sacrum or coccyx were excluded. Differences in the sacrococcygeal morphology among age groups stratified by decade of life and between genders were analyzed using sagittal plane pelvic CT scans. The morphological parameters studied were the sacral and coccygeal curved indexes, sacrococcygeal angle, intercoccygeal angle, coccygeal type, coccygeal segmental number, and sacrococcygeal fusion.ResultsThe average sacral and coccygeal curved indexes were 6.15 and 7.41, respectively. The average sacrococcygeal and intercoccygeal angles were 110° and 49°, respectively. Type II coccyx was most common, and the rate of sacrococcygeal fusion was 34%. There was a moderate positive correlation between age and the sacral curved index (r = 0.493, p = 0.000) and a weak negative correlation between age and the coccyx curved index (r = −0.257, p = 0.000). There was a weak negative correlation between age and the intercoccygeal angle (r = −0.187, p = 0.000). The average intercoccygeal angle in males and females was 53.9° and 44.7°, respectively.ConclusionsThe sacrum tended to be more curved and the coccyx straighter with age. The coccyx was straighter in females than males. Knowledge of the sacrococcygeal anatomy of Koreans will promote better understanding of anatomical differences among ethnicities and future studies on coccydynia.
A 58-year-old male patient who had developed left knee pain with a history of trauma was referred to our hospital. Physical examination and further examination by magnetic resonance imaging revealed results that closely resemble a horizontal tear of the lateral meniscus and a tear of the medial meniscus. Arthroscopically, we found a cord-like structure originating from the posterior 1/3 portion of the lateral meniscus and passing obliquely toward the medial femoral condyle in front of the posterior cruciate ligament without a tear of the lateral meniscus. In this report, we describe a rare case of anterior meniscofemoral ligament that was clearly seen on arthroscopy and mimicked a meniscal tear, which is also known as a pseudo-tear of the meniscus.
Study Design:
This was a retrospective cohort study.
Objective:
To evaluate the correlation between preoperative radiologic degree and the postoperative prognosis in lumbar foraminal stenosis (LFS) patients who required decompression.
Summary of Background Data:
There have been only a few studies for postoperative prognosis according to the degree of preoperative stenosis in patients requiring surgery.
Materials and Methods:
The shape and severity of LFS was classified according to Lee et al’s classification. Radiating leg pain was assessed preoperatively and at the last follow-up. Oswestry Disability Index (ODI), Roland Morris Disability Questionnaire (RMDQ), SF-36 Physical Component Score (PCS), and SF-36 Mental Component Score (MCS) were surveyed at the last follow-up. Mean follow-up was 6.3 years.
Results:
Among 130 patients, 34 cases were classified as Grade 1T (transverse), 31 cases as Grade 1V (vertical), 32 cases as Grade 2, and 33 cases as Grade 3. The mean age was 65.0 years. Radiating leg pain (Visual Analogue Scale) preoperatively and lastly was 6.8 and 2.3, respectively in Grade 1T; 7.4 and 3.3, respectively in Grade 1V; 7.7 and 3.0, respectively in Grade 2; and 7.4 and 2.9, respectively in Grade 3. ODI and RMDQ at the last follow-up were 13.9 and 6.3, respectively in Grade 1T; 23.1 and 11.2, respectively in Grade 1V; 18.8 and 12.3, respectively in Grade 2; 21.6 and 11.7, respectively in Grade 3. Grade 1T had significantly lower value than Grade 1V, 2 and 3 in ODI and RMDQ, respectively. SF-36 PCS and MCS at the last follow-up were 62.2 and 70.5, respectively in Grade 1T; 33.7 and 40.3, respectively in Grade 1V; 42.1 and 48.2, respectively in Grade 2; 37.0 and 48.5, respectively in Grade 3. Grade 1T had significantly higher value than grade 1V, 2 and 3 in SF-36 PCS and MCS, respectively.
Conclusions:
Decompression for LFS was effective for reducing leg radiating pain. Functional outcome and quality of life was better in mild transverse type implying the role of dorsal root ganglion and dynamic stenosis.
Unstable pelvic ring injuries are potentially life-threatening and associated with high mortality and complication rates in polytrauma patients. The most common cause of death in patients with pelvic ring injuries is massive bleeding. With resuscitation, external fixation can be performed as a temporary stabilization procedure for hemostasis in unstable pelvic fractures. Internal fixation following temporary external fixation of the pelvic ring yields superior and more reliable stabilization. However, a time-consuming extended approach to open reduction and internal fixation of the pelvic ring is frequently precluded by an unacceptable physiologic condition and/or concomitant injuries in patients with multiple injuries. Conservative treatment may lead to pelvic ring deformity, which is associated with various functional disabilities such as limb length discrepancy, gait disturbance, and sitting intolerance. Therefore, if the patient is not expected to be suitable for additional surgery due to a poor expected physiologic condition, definitive external fixation in combination with various percutaneous screw fixations to restore the pelvic ring should be considered in the acute phase. Herein, we report a case of unstable pelvic ring injury successfully treated with definitive external fixation and percutaneous screw fixation in the acute phase in a severely injured polytrauma patient.
A high-speed impedance measurement system was developed, which enables the measurement of various characteristics of CW and pulsed plasmas with time resolution of less than a microsecond. For this system, a voltage and current sensor is implemented in a printed circuit board to sense the radio frequency signals. A digital board, which has a high-speed analog to digital converter and a field-programmable gate-array, is used to calculate the impedance of the signal. The final output of impedance is measured and stored with a maximum speed of 3 Msps. This sensor system was tested in a pulsed-plasma by applying it to the point between the matching box and the plasma chamber. The experimental equipment was constructed connecting the matching box, a 13.56 MHz generator, a 2 MHz generator that produced pulsed power, and a pulse-signal generator. From the temporal behavior of the measured impedance, we were able to determine the time intervals of transient states, especially of the initial active state. This information can be used to set the pulse frequency and duty for plasma processing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.