There is an increasing demand of air filters with a high collection performance, i.e., high collection efficiency and low pressure drop, for the application to indoor air cleaning. Air filters consisting of nanofibers have attracted great interests since they may have a low pressure drop because of slip flow effect and high collection efficiency due to interception. Although various nanofiber filters are available on the market, their collection performance is not as high as expected by the conventional filtration theory because non-uniform packing of fibers plays a significant role. In the present work, the collection performance of nanofiber (780 nm) and microfiber (11.2 µm) mixed filters with various mixing fractions was studied in order to maximize the quality factor of filter, q F , as a function of mixing fraction of nanofibers. The collection performance of mixed fiber filters was predicted by using theoretical equations reported by Bao et al. (1998) for bimodal distribution of fibers. As a result, it was found that the mixed fiber filters had a uniform fiber packing compared to laminated filters and that the collection efficiency was well predicted by introducing the inhomogeneity factor calculated for the filter consisting of two distinct fiber sizes. Furthermore, we found that the mixed fiber filter with the nanofiber mixing fraction of 5% in mass had the highest quality factor.
Breathing machines are widely used to evaluate respirator performance but they are capable of generating only limited air flow patterns, such as, sine, triangular and square waves. In order to evaluate the respirator performance in practical use, it is desirable to test the respirator using the actual breathing patterns of wearers. However, it has been a difficult task for a breathing machine to generate such complicated flow patterns, since the human respiratory volume changes depending on the human activities and workload. In this study, we have developed an electromechanical breathing simulator and a respiration sampling device to record and reproduce worker’s respiration. It is capable of generating various flow patterns by inputting breathing pattern signals recorded by a computer, as well as the fixed air flow patterns. The device is equipped with a self-control program to compensate the difference in inhalation and exhalation volume and the measurement errors on the breathing flow rate. The system was successfully applied to record the breathing patterns of workers engaging in welding and reproduced the breathing patterns.
Experimental contamination by exogenous DNA is a major issue in molecular biological studies for data quality and its management. We herein assessed DNA aerosols for the risk of contamination and tested the capacity of clean air filters to trap and remove DNA aerosols. DNA aerosols were generated by atomizing a DNA solution and introduced into a laminar flow clean air unit. Capture and detection performed upstream and downstream of the clean air unit showed that a significant fraction (>99.96%) of introduced molecules was trapped and removed by the filter. Although DNA aerosols appear to be an avoidable source of exogenous contamination, a clearer understanding and careful experimental procedures are needed in order to perform contamination-free, high-quality molecular biology experiments.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.